1-800-397-1392
Today's Hours 8am - 9pm est
In stock
AHRI Number:212394317
How is it different from a traditional heat pump?
Inverter Condenser - Inverter technology changes AC power to DC, allowing the compressor inside your condenser to speed up and slow down. This enables the system to self-adjust BTU output based on demand. As the weather changes, so will your system output.
Learning System - This system is equipped with sensors that monitor air temperature inside and outside, system performance, duct pressure, and refrigerant temperature. Upon initial startup, it enters a learning mode, keeping air moving across the sensors and storing information to ensure future startups and run cycles are optimized for maximum efficiency.
Size for Heat - The self-adjusting inverter design allows you to size your system based on heat demand. Unlike standard heat pumps, which can lead to a muggy house in summer if sized for heat, the ACiQ 5-ton heat pump system automatically adjusts to run like a smaller unit to keep you cool and dry.
With an efficiency rating of 15.2 SEER2, the variable output ACiQ-60-EHPB / ACiQ-60-AHB will keep you comfortable across a wide range of conditions. Use our handy size calculator here to determine the demand for your home. For cooling, this system can operate anywhere from 12,000 BTU to 60,000 BTU without short cycling.
Inverter Condenser - Inverter technology changes AC power to DC, allowing the compressor inside your condenser to speed up and slow down. This allows the system to self-adjust BTU output based on demand. As the weather changes, so will your system output.
Learning System - This system is packed with sensors and controls – air temperature inside and outside, system performance, duct pressure, refrigerant temperature. The first time you start your system it enters a learning mode keeping air moving across the sensors and storing information so future startups and run cycles will be at max efficiency.
Size for Heat - The self-adjusting inverter design allows you to size your system based on heat demand. With standard heat pumps, sizing for heat can mean a muggy house during summer. The ACiQ High Efficiency 5-ton heat pump system automatically adjusts to run like a 4-ton, 3-ton or a 2-ton to keep you cool and dry.
With an efficiency rating of 15.2 SEER2, the variable output SC-60-EHPB will keep you comfortable across a wide range of conditions. Use our handy size calculator here to determine the demand for your home. For cooling, this system can operate anywhere from 12,000 BTU to 36,000 BTU without short cycling.
The SC-60-AHB air handler features a variable DC blower and communicating technology to maximize comfort and efficiency at the same time. The included smart thermostat communicates with the inverter condenser outside, and the variable air handler inside, allowing the system to self-adjust BTU output to maximize efficiency while providing ideal comfort. The air handler efficiently distributes heated and cooled air throughout your home by attaching to your existing ductwork.
Installation is very similar to installing any replacement air handler. Your technician will make electrical, refrigerant, thermostat and communication connections, plus, connect to your return and supply ductwork. The ACiQ Next Gen Air Handler is multi-positional (upflow, downflow or horizontal) and mobile-home approved. Any 24V thermostat with 2 stages of heating can control the system, although the supplied thermostat is recommended. You can add electric strip heat as a backup system for the coldest days of the year. The intelligent control board in the air handler displays fault codes in case part of the system requires maintenance.
Please note - in order to function as a heat pump, this air handler must be installed with a condenser and other installation equipment, available at an additional cost if not already included in this product bundle. To use straight electric heating, an electric heater coil is necessary and is also available at an additional cost.
ACiQ 5 Ton 15.2 SEER High Efficiency Central Heat Pump | Inverter | |
---|---|
SKU | SC-60-EHPB |
Weight | 223.700000 |
Manufacturer | ACiQ |
HSPF2 | 7.8 |
Cooling BTU | 54,000 BTU |
Heating BTU | 54,000 BTU |
Maximum CFM | 3529 |
Decibel Level (dBA) | 75 |
Electric Heat | Heat Pump |
Refrigerant | R410A |
SEER2 | 15.2 |
EER | 10 |
Condenser Stages | Variable Speed |
Compressor Type | Rotary |
Liquid Line | 3/8" |
Suction Line | 3/4" |
Electrical | 208/230V 1 Phase 60 Hz |
Max Breaker Size | 45 Amps |
Min. Breaker Size | 32 Amps |
Tonnage | 5 Ton |
BTU/Tonnage | 60,000 BTU/5 Ton |
Min/Max Outdoor Temp for Heating | 5~75 |
Min/Max Outdoor Temp for Cooling | 5~118 |
Height | 37.81" |
Width | 39" |
Depth | 14.56" |
Warranty | 12 year compressor, 7 year parts with online registration |
Resources | You will need Adobe® Acrobat® Reader to view PDF documents. |
Safety Information | PROPOSITION 65 WARNING |
5 Ton ACiQ Central Air Handler | |
SKU | SC-60-AHB |
Refrigerant Charge | 197.60 |
Weight | 203.900000 |
Manufacturer | ACiQ |
HSPF | 7.8 |
Cooling BTU | 54000 BTU |
Heating BTU | 54000 BTU |
Maximum CFM | 1500 |
Decibel Level (dBA) | 54 |
Electric Heat | Heat Pump |
Electric Backup Heat Capabilities (Optional) | 5 Kilowatts, 10 Kilowatts |
Energy Star | Yes |
Refrigerant | R410A |
SEER2 | 15.2 |
EER | 10 |
Liquid Line | 3/8" |
Suction Line | 3/4" |
Electrical | 208/230V 1 Phase 60 Hz |
Max Breaker Size | 15 |
Min. Breaker Size | 7.5 |
Tonnage | 5 Ton |
BTU/Tonnage | 60,000 BTU/5 Ton |
Mini Split Type | Multi-Positional |
Zone Compatibility | Single Zone |
Height | 57" |
Width | 24.75" |
Depth | 21.25" |
Warranty | 14 year compressor, 5 year parts with online registration |
Resources | You will need Adobe® Acrobat® Reader to view PDF documents. |
Safety Information | PROPOSITION 65 WARNING |