We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
1-800-397-1392
Today's Hours 8am - 11pm estThe ACiQ-42-HPD outdoor heat pump condenser, paired with the ACiQ-42-AHD air handler, is genuinely a variable speed system that uses an inverter-driven compressor; however, it is frequently described as having two stages because it can be wired and controlled by a two-stage thermostat in non-communicating setups.
If you have any further questions, please call us and we will be happy to assist you.