Read our privacy policyThe Airrex AHSC-60 480/3 is a 60,000 BTU cooling and 60,000 BTU heating portable heat pump designed to provide high-capacity supplemental heating, cooling, and dehumidification for commercial and industrial environments. Combining 5-ton heating and cooling capacity with reversible heat pump technology and ducted air distribution, this self-contained climate control system provides year-round temperature management for demanding workspaces. Its 480V three-phase electrical configuration makes it suitable for facilities equipped with compatible industrial power infrastructure, while its portable construction supports flexible deployment where permanent HVAC installation is impractical.
The Airrex AHSC-60 480/3 provides 60,000 BTU/h (17.6 kW) of heating capacity to help maintain comfortable temperatures in suitable commercial and industrial environments. Its specified heating operating range is approximately 50°F to 81°F, subject to the manufacturer's stated ambient conditions. Reversible heat pump operation transfers heat into the conditioned space, providing supplemental heating for workshops, warehouses, manufacturing facilities, equipment areas, and temporary workspaces. Actual heating performance depends on ambient conditions, installation configuration, and the thermal load of the conditioned space.
The Airrex AHSC-60 480/3 provides 60,000 BTU/h (17.6 kW) of cooling capacity, equivalent to approximately 5 tons, for high-capacity supplemental cooling. Its specified cooling operating range is approximately 65°F to 113°F under the manufacturer's stated ambient conditions. The unit is intended for applications requiring substantial cooling capacity, including industrial work areas, equipment rooms, workshops, and temporary commercial spaces. Actual cooling performance depends on ambient temperature, insulation, ceiling height, equipment heat loads, ventilation, and duct configuration. Correct duct sizing and routing are essential for maintaining airflow and system performance.
The Airrex AHSC-60 480/3 uses reversible heat pump technology to provide both heating and cooling from a single portable system. In cooling mode, the refrigeration cycle removes heat from the conditioned space. In heating mode, the cycle reverses to deliver warm air. The system also provides a dedicated dehumidification mode for moisture removal. The AHSC-60 480/3 uses R-410A refrigerant, with a specified refrigerant charge of approximately 6.62 lb. This integrated approach provides year-round temperature control without requiring separate portable heating and cooling equipment. Refrigerant servicing must be performed by qualified personnel using appropriate procedures and equipment.
The Airrex AHSC-60 480/3 incorporates separate supply and return air connections for flexible conditioned-air delivery and circulation. The indoor centrifugal fan provides a rated airflow of approximately 1,620 CFM, while the outdoor axial fan provides approximately 3,240 CFM. The system uses one 12-inch supply duct and one 16-inch return duct, with a maximum external static pressure of 0.9 inches of water column and a maximum equivalent indoor duct length of 65 feet. These features support ducted installation arrangements in commercial and industrial environments. Duct lengths, routing, clearances, and ventilation must follow the manufacturer's installation requirements to maintain appropriate airflow and operating performance.
The Airrex AHSC-60 480/3 features a heavy-duty cabinet designed for portable commercial and industrial applications. Published specifications list approximate dimensions of 29.1 inches wide by 57.1 inches deep by 50.7 inches high, with a net weight of approximately 586 lb. Integrated caster wheels support positioning on suitable surfaces, while separate duct connections allow conditioned air to be routed toward the intended space. The unit is designed for a 460–480V-class, 60Hz, three-phase electrical supply; the manufacturer's AHSC-60 specification lists a nominal supply of 460V. Confirm the exact unit nameplate and approved voltage range before connecting the 480V supply. Due to its substantial weight, relocation requires appropriate handling equipment and safe movement procedures.
The Airrex AHSC-60 480/3 incorporates a dedicated dehumidification mode to help manage excess moisture in commercial and industrial environments. Published AHSC-60 specifications identify maximum moisture removal of approximately 77 gallons per day at 89°F and 80% relative humidity, with nominal moisture removal of approximately 53 gallons per day at 80°F and 60% relative humidity. Actual moisture removal varies with ambient temperature, humidity, airflow, and operating conditions. The specified dehumidification operating range is approximately 59°F to 113°F. An optional compatible condensate pump is available for installations requiring automatic condensate removal. Drainage arrangements must be configured according to the manufacturer's instructions.
The Airrex AHSC-60 480/3 features a digital control panel for power, temperature adjustment, operating-mode selection, and timer settings. Available modes include cooling, heating, fan operation, and dehumidification. The controller displays room temperature and selected settings and incorporates diagnostic indicators for supported operating faults. The unit's nominal power supply is 460V AC, 60Hz, three-phase, with compatibility for the specified 480V-class industrial supply subject to the equipment nameplate. Published specifications list power consumption of approximately 6.9 kW during cooling and 6.2 kW during heating, with current consumption of 10.6 amps during cooling and 9.7 amps during heating. The specified fuse rating is 15 amps, and the published voltage operating range is approximately 391V to 506V. The unit does not use a standard NEMA plug in this configuration. Electrical connections, disconnect equipment, conductors, and overcurrent protection must comply with the manufacturer's wiring diagram, equipment nameplate, and applicable electrical codes. Installation must be completed by qualified personnel.
The Airrex AHSC-60 480/3 is designed for commercial and industrial environments requiring high-capacity portable cooling, heating, and dehumidification. Potential applications include manufacturing facilities, warehouses, workshops, maintenance areas, machine rooms, server rooms, industrial production areas, and temporary workspaces. Its 60,000 BTU/h heating and cooling capacities, ducted air distribution, and three-phase electrical configuration make it suitable for applications where permanent HVAC installation is impractical or temporary conditioning is required. Proper application sizing, electrical capacity, duct routing, ventilation, ambient operating conditions, and condensate management should be evaluated before deployment.
The Airrex AHSC-60 480/3 is designed for deployment in different commercial and industrial work areas as temperature-control requirements change. Its heavy-duty cabinet incorporates caster wheels, including locking casters, to support positioning on suitable surfaces. Separate duct connections allow conditioned air to be directed toward the intended space while supporting flexible equipment placement. Given the unit's approximate 586 lb weight, relocation requires appropriate handling equipment and safe movement procedures. Secure the unit in its operating position and follow the manufacturer's instructions for shutdown, duct disconnection, transportation, and repositioning.
The Airrex AHSC-60 480/3 includes removable aluminum and stainless-steel mesh air filters to simplify routine cleaning and help maintain airflow. Regular filter inspection and cleaning are important for maintaining system performance. Built-in protection features include high- and low-pressure switches, a three-minute compressor delay timer, compressor thermostat protection, fan motor protection, and automatic full-tank shutoff. The control system provides diagnostic indicators to assist with troubleshooting. Condensate drainage components should be inspected regularly, and any optional condensate pump should be maintained according to its manufacturer's instructions. Refrigeration-system servicing, electrical repairs, and internal component maintenance should be performed by qualified service personnel in accordance with the applicable installation and operating manual.
Warranty coverage for the Airrex AHSC-60 480/3 is subject to the manufacturer's written warranty terms. The applicable coverage period, compressor coverage, exclusions, service requirements, and proof-of-purchase conditions should be confirmed using the warranty documentation supplied with the purchased unit.
Experience flexible commercial and industrial climate control with the Airrex AHSC-60 480/3 portable heat pump. Combining 60,000 BTU/h of cooling capacity and 60,000 BTU/h of heating capacity with reversible heat pump technology, R-410A refrigerant, ducted air distribution, and integrated dehumidification, this heavy-duty portable system provides year-round temperature management for commercial and industrial work areas requiring high-capacity supplemental HVAC performance.
All AirRex commercial unit sales are final and are non-refundable.