Read our privacy policyThe AmeriCool WWC-1200 is a high-capacity portable water chiller designed to provide chilled-water circulation for industrial process cooling, equipment temperature control, and commercial applications requiring substantial heat removal. Delivering a rated cooling capacity of 146,000 BTU/h, equivalent to approximately 12.2 tons of refrigeration, this self-contained system combines a three-phase scroll compressor, an integrated 3 HP circulation pump, a design flow rate of 72 GPM, and a built-in water tank. Designed to support industrial equipment and process-water circuits, the WWC-1200 provides centralized chilled-water delivery while helping simplify system deployment, water management, and temperature control in suitable industrial environments.
The AmeriCool WWC-1200 is a self-contained portable water chiller designed for industrial process-water circuits and compatible equipment requiring chilled-water circulation. It provides a rated cooling capacity of 146,000 BTU/h, equivalent to approximately 12.2 tons of refrigeration, and incorporates a three-phase scroll compressor, an integrated circulation pump, and a built-in water tank. Its specified electrical supply is 460V, 60Hz, three-phase, although the electrical ratings should be confirmed against the documentation supplied with the specific unit. Before installation, verify that the chiller's cooling capacity, water temperature range, flow requirements, connection sizes, and electrical characteristics match the requirements of the connected equipment.
The AmeriCool WWC-1200 uses a three-phase scroll compressor and R-410A refrigerant to produce chilled water for compatible industrial applications. Its rated cooling capacity of 146,000 BTU/h supports process cooling and equipment temperature management where substantial heat removal is required. The integrated 3 HP circulation pump provides a design flow rate of 72 GPM to move water through the connected process circuit. Actual cooling performance depends on ambient conditions, inlet water temperature, fluid characteristics, flow rate, and the thermal load. Confirm the required cooling capacity and operating conditions before selecting the unit for a specific process.
The AmeriCool WWC-1200 features 1.5-inch supply and return water connections for integration with a compatible process-water circuit. Its integrated 3 HP pump provides a design flow rate of 72 GPM to support chilled-water circulation between the chiller and the connected application. Correct piping configuration and adequate water supply are essential for maintaining the intended cooling performance. Use compatible pipes, fittings, valves, and hoses rated for the operating temperature and pressure. Verify the system's pressure drop, required flow, connection arrangement, and piping requirements against the manufacturer's installation documentation before commissioning.
The AmeriCool WWC-1200 combines its refrigeration system, circulation pump, water tank, and electronic controls in a single portable industrial unit. Published dimensions are approximately 35.4 inches wide, 57.8 inches deep, and 65.2 inches high, with a listed net weight of approximately 864 pounds (392 kg). Install the chiller on a stable, level surface in a well-ventilated location with adequate clearance around its air intake, condenser, and service panels. Installation requires suitable water piping and a compatible 460V, 60Hz, three-phase electrical supply. Electrical protection, conductor sizing, grounding, phase sequence, and disconnect requirements must be verified against the unit's wiring diagram and applicable electrical codes. Installation and electrical connections should be completed by qualified personnel.
The AmeriCool WWC-1200 incorporates wheels and handling provisions to support movement and positioning within industrial facilities. Its self-contained design brings the refrigeration equipment, circulation pump, water tank, and control system together in one unit, supporting deployment where a dedicated chilled-water source is required. With a listed net weight of approximately 864 pounds, the chiller requires suitable material-handling equipment and a stable installation surface. Before relocation, shut down the unit, disconnect electrical power, and isolate or disconnect water connections as required. After repositioning, verify that the chiller is level, ventilation openings are unobstructed, and all water and electrical connections are secure before restarting.
The AmeriCool WWC-1200 is designed for industrial and commercial cooling environments requiring high-capacity chilled-water production. Its integrated refrigeration and circulation components support operation as a centralized process-cooling unit. The manufacturer specifies an ambient operating range of 50°F to 113°F and a water inlet temperature range of 41°F to 86°F. Maintain suitable ventilation and keep condenser surfaces and air openings free of dust and debris to support heat rejection. Specific enclosure materials, corrosion-resistance ratings, and environmental protection classifications should be confirmed from the manufacturer's technical documentation before use in corrosive, wet, or otherwise demanding environments.
The AmeriCool WWC-1200 features an electronic control system for monitoring water temperatures, adjusting the target temperature, and identifying abnormal operating conditions. Its documented diagnostic functions include water-shortage detection, refrigerant monitoring, and freeze-prevention sensing. These functions help operators identify potential problems affecting the refrigeration or water-circulation system. The manufacturer's owner’s manual lists a water inlet operating range of 41°F to 86°F (5°C to 30°C). The manual and current product page report differing electrical consumption and current figures, so the unit's nameplate and supplied wiring documentation should be used to confirm the correct electrical requirements. The chiller's controls should be operated according to the manufacturer's instructions and the requirements of the connected process.
The AmeriCool WWC-1200 is designed for industrial and commercial applications requiring high-capacity chilled-water circulation, including manufacturing operations, industrial machinery, production equipment, and compatible process-cooling systems. Its rated cooling capacity of 146,000 BTU/h and design flow rate of 72 GPM support applications requiring substantial heat removal through a circulating water loop. The integrated pump and water tank provide a consolidated cooling arrangement, while the onboard diagnostic functions assist with operational monitoring. Suitability depends on the process heat load, target water temperature, required flow and pressure, fluid compatibility, and installation conditions. Verify these parameters before integrating the chiller into a production or equipment-cooling system.
The AmeriCool WWC-1200 incorporates water-shortage detection, freeze-prevention sensing, and refrigerant monitoring to assist with troubleshooting and routine operation. Regular maintenance should include inspection of the water tank, supply and return piping, valves, and connections for leakage, contamination, or damage. Keep condenser surfaces and ventilation openings clean to support heat rejection, and check the water level and fluid condition according to the manufacturer's maintenance instructions. The owner’s manual identifies distilled water and tap water mixed with 10% antifreeze as permitted fluid options; confirm the approved fluid and mixture requirements before filling the system. Before maintenance, shut down the chiller and disconnect electrical power. Refrigeration-system servicing, electrical repairs, and work involving pressurized components must be performed by qualified personnel.
According to the supplied warranty information, AmeriCool provides 12 months of parts-and-labor coverage for the complete unit and 12 months of parts-and-labor coverage for the compressor, beginning from the end user's purchase date. Warranty claims require the original purchase invoice and are subject to the manufacturer's terms, conditions, and exclusions. Refer to the official warranty documentation supplied with the AmeriCool WWC-1200 to confirm the applicable coverage, claim procedures, and any additional requirements.
Support demanding industrial cooling requirements with the AmeriCool WWC-1200 portable water chiller. Combining 146,000 BTU/h of rated cooling capacity with a three-phase scroll compressor, an integrated 3 HP circulation pump, a 72 GPM design flow rate, and a built-in water tank, this self-contained chilled-water system is designed to provide process temperature control for manufacturing facilities, industrial machinery, production equipment, and compatible commercial applications requiring high-capacity chilled-water circulation.
""All AmeriCool commercial unit sales are final and are non-refundable.