AmeriCool 12 Ton 146,000 BTU Air-Cooled Chiller | 460V - R410A

AmeriCool 12 Ton 146,000 BTU Air-Cooled Chiller | 460V - R410A
SAVE $10,574.55
By

AmeriCool

In stock
Model

WWC-1200

ID

122921

Was $34,073.55 Your Low Price Special Price $23,499.00
Ships in 5-7 Business Days
Free Shipping
 
Product Features
  • Built-in self-diagnostic system for safe, reliable performance
  • Heavy-duty construction built for continuous-duty use
  • High-capacity cooling for large industrial and commercial applications
  • Energy-efficient operation with low maintenance requirements

High-Capacity Industrial Process Cooling Portable Water Chiller with 146,000 BTU/h Cooling Capacity – AmeriCool WWC-1200

The AmeriCool WWC-1200 is a high-capacity portable water chiller designed to provide chilled-water circulation for industrial process cooling, equipment temperature control, and commercial applications requiring substantial heat removal. Delivering a rated cooling capacity of 146,000 BTU/h, equivalent to approximately 12.2 tons of refrigeration, this self-contained system combines a three-phase scroll compressor, an integrated 3 HP circulation pump, a design flow rate of 72 GPM, and a built-in water tank. Designed to support industrial equipment and process-water circuits, the WWC-1200 provides centralized chilled-water delivery while helping simplify system deployment, water management, and temperature control in suitable industrial environments.

Key Benefits

  • High-Capacity Cooling Performance – Provides 146,000 BTU/h of rated cooling capacity for demanding industrial process and equipment-cooling applications.
  • Integrated Refrigeration System – Uses a three-phase scroll compressor and R-410A refrigerant to support high-capacity chilled-water production.
  • Integrated Water Circulation – Features a 3 HP circulation pump with a design flow rate of 72 GPM to support process-water movement.
  • Built-In Water Tank – Integrates water storage into the chiller system, reducing the need for a separately installed external tank, depending on the supplied configuration.
  • Dedicated Water Connections – Provides 1.5-inch supply and return connections for integration with a compatible process-water circuit.
  • Industrial Portable Construction – Incorporates wheels and handling provisions to support positioning within suitable industrial facilities.
  • Integrated Diagnostic Protection – Includes water-shortage detection, freeze-prevention sensing, and refrigerant monitoring to help identify abnormal operating conditions.
  • Flexible Water Management – Supports the optional 120-liter tank configuration and compatible automatic water-supply device, subject to the selected unit configuration.

High-Capacity Cooling – Portable Water Chiller Compatibility

The AmeriCool WWC-1200 is a self-contained portable water chiller designed for industrial process-water circuits and compatible equipment requiring chilled-water circulation. It provides a rated cooling capacity of 146,000 BTU/h, equivalent to approximately 12.2 tons of refrigeration, and incorporates a three-phase scroll compressor, an integrated circulation pump, and a built-in water tank. Its specified electrical supply is 460V, 60Hz, three-phase, although the electrical ratings should be confirmed against the documentation supplied with the specific unit. Before installation, verify that the chiller's cooling capacity, water temperature range, flow requirements, connection sizes, and electrical characteristics match the requirements of the connected equipment.

Integrated Refrigeration – System Performance and Function

The AmeriCool WWC-1200 uses a three-phase scroll compressor and R-410A refrigerant to produce chilled water for compatible industrial applications. Its rated cooling capacity of 146,000 BTU/h supports process cooling and equipment temperature management where substantial heat removal is required. The integrated 3 HP circulation pump provides a design flow rate of 72 GPM to move water through the connected process circuit. Actual cooling performance depends on ambient conditions, inlet water temperature, fluid characteristics, flow rate, and the thermal load. Confirm the required cooling capacity and operating conditions before selecting the unit for a specific process.

1.5-Inch Supply and Return Connections – Water Flow

The AmeriCool WWC-1200 features 1.5-inch supply and return water connections for integration with a compatible process-water circuit. Its integrated 3 HP pump provides a design flow rate of 72 GPM to support chilled-water circulation between the chiller and the connected application. Correct piping configuration and adequate water supply are essential for maintaining the intended cooling performance. Use compatible pipes, fittings, valves, and hoses rated for the operating temperature and pressure. Verify the system's pressure drop, required flow, connection arrangement, and piping requirements against the manufacturer's installation documentation before commissioning.

Integrated Components – Installation and Setup

The AmeriCool WWC-1200 combines its refrigeration system, circulation pump, water tank, and electronic controls in a single portable industrial unit. Published dimensions are approximately 35.4 inches wide, 57.8 inches deep, and 65.2 inches high, with a listed net weight of approximately 864 pounds (392 kg). Install the chiller on a stable, level surface in a well-ventilated location with adequate clearance around its air intake, condenser, and service panels. Installation requires suitable water piping and a compatible 460V, 60Hz, three-phase electrical supply. Electrical protection, conductor sizing, grounding, phase sequence, and disconnect requirements must be verified against the unit's wiring diagram and applicable electrical codes. Installation and electrical connections should be completed by qualified personnel.

Wheeled Construction – Portable System Integration

The AmeriCool WWC-1200 incorporates wheels and handling provisions to support movement and positioning within industrial facilities. Its self-contained design brings the refrigeration equipment, circulation pump, water tank, and control system together in one unit, supporting deployment where a dedicated chilled-water source is required. With a listed net weight of approximately 864 pounds, the chiller requires suitable material-handling equipment and a stable installation surface. Before relocation, shut down the unit, disconnect electrical power, and isolate or disconnect water connections as required. After repositioning, verify that the chiller is level, ventilation openings are unobstructed, and all water and electrical connections are secure before restarting.

Industrial Construction – Durability and Operating Conditions

The AmeriCool WWC-1200 is designed for industrial and commercial cooling environments requiring high-capacity chilled-water production. Its integrated refrigeration and circulation components support operation as a centralized process-cooling unit. The manufacturer specifies an ambient operating range of 50°F to 113°F and a water inlet temperature range of 41°F to 86°F. Maintain suitable ventilation and keep condenser surfaces and air openings free of dust and debris to support heat rejection. Specific enclosure materials, corrosion-resistance ratings, and environmental protection classifications should be confirmed from the manufacturer's technical documentation before use in corrosive, wet, or otherwise demanding environments.

Electronic Temperature Monitoring – Controls and System Operation

The AmeriCool WWC-1200 features an electronic control system for monitoring water temperatures, adjusting the target temperature, and identifying abnormal operating conditions. Its documented diagnostic functions include water-shortage detection, refrigerant monitoring, and freeze-prevention sensing. These functions help operators identify potential problems affecting the refrigeration or water-circulation system. The manufacturer's owner’s manual lists a water inlet operating range of 41°F to 86°F (5°C to 30°C). The manual and current product page report differing electrical consumption and current figures, so the unit's nameplate and supplied wiring documentation should be used to confirm the correct electrical requirements. The chiller's controls should be operated according to the manufacturer's instructions and the requirements of the connected process.

Manufacturing and Process Applications – Commercial and Industrial Use

The AmeriCool WWC-1200 is designed for industrial and commercial applications requiring high-capacity chilled-water circulation, including manufacturing operations, industrial machinery, production equipment, and compatible process-cooling systems. Its rated cooling capacity of 146,000 BTU/h and design flow rate of 72 GPM support applications requiring substantial heat removal through a circulating water loop. The integrated pump and water tank provide a consolidated cooling arrangement, while the onboard diagnostic functions assist with operational monitoring. Suitability depends on the process heat load, target water temperature, required flow and pressure, fluid compatibility, and installation conditions. Verify these parameters before integrating the chiller into a production or equipment-cooling system.

Water-Level Monitoring – Service and Maintenance

The AmeriCool WWC-1200 incorporates water-shortage detection, freeze-prevention sensing, and refrigerant monitoring to assist with troubleshooting and routine operation. Regular maintenance should include inspection of the water tank, supply and return piping, valves, and connections for leakage, contamination, or damage. Keep condenser surfaces and ventilation openings clean to support heat rejection, and check the water level and fluid condition according to the manufacturer's maintenance instructions. The owner’s manual identifies distilled water and tap water mixed with 10% antifreeze as permitted fluid options; confirm the approved fluid and mixture requirements before filling the system. Before maintenance, shut down the chiller and disconnect electrical power. Refrigeration-system servicing, electrical repairs, and work involving pressurized components must be performed by qualified personnel.

Warranty

According to the supplied warranty information, AmeriCool provides 12 months of parts-and-labor coverage for the complete unit and 12 months of parts-and-labor coverage for the compressor, beginning from the end user's purchase date. Warranty claims require the original purchase invoice and are subject to the manufacturer's terms, conditions, and exclusions. Refer to the official warranty documentation supplied with the AmeriCool WWC-1200 to confirm the applicable coverage, claim procedures, and any additional requirements.

Recommended Accessories

  • Optional 120-Liter Water Tank Configuration – Provides the specified optional tank capacity for compatible water-management arrangements; confirm whether the tank is included with the selected unit.
  • Automatic Water-Supply Device – An optional manufacturer-described accessory intended to replenish the water tank when the water level becomes insufficient.
  • 1.5-Inch Water Supply and Return Piping – Compatible piping, fittings, and valves for connecting the chiller to the process-water circuit; verify connection dimensions and pressure ratings before installation.
  • Compatible Water Drainage Components – Suitable drain fittings and hoses for water removal during maintenance or extended storage, subject to the manufacturer's connection requirements.
  • Manufacturer-Approved Water or Antifreeze Mixture – Use distilled water or an approved fluid mixture in accordance with the owner's manual and the required operating temperatures.
  • Electrical Disconnect and Circuit Protection – Appropriately rated electrical components selected according to the verified unit voltage, current, conductor sizing, and installation requirements.

High-Capacity Industrial Process Cooling with the AmeriCool WWC-1200

Support demanding industrial cooling requirements with the AmeriCool WWC-1200 portable water chiller. Combining 146,000 BTU/h of rated cooling capacity with a three-phase scroll compressor, an integrated 3 HP circulation pump, a 72 GPM design flow rate, and a built-in water tank, this self-contained chilled-water system is designed to provide process temperature control for manufacturing facilities, industrial machinery, production equipment, and compatible commercial applications requiring high-capacity chilled-water circulation.

""

No Return Policy

All AmeriCool commercial unit sales are final and are non-refundable.

More Information
AmeriCool 12 Ton 146,000 BTU Air-Cooled Chiller | 460V - R410A
FeatureSpec
SKUWWC-1200
Weight (in lbs)864
Brand/ManufacturerAmeriCool
Additional InformationNo Return Policy
Cooling BTU146,000
RefrigerantR410A
Electrical460V 3 Phase 60hz
PhaseThree Phase
Max Breaker Size 20.8 Amps
Tonnage12.5 Ton
Operating ModeCooling
Height65″
Width58″
Depth36″
Operating Temperature 50℉~113℉
Warranty2 years parts, no labor
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:AmeriCool 12 Ton 146,000 BTU Air-Cooled Chiller | 460V - R410A
Your Rating
Customer Questions
What is the CEER rating?
These are commercial grade units, and do not come with CEER ratings. If you have any further questions, please feel free to give us a call. Thanks!
Did you find what you were looking for?
Why Choose AmeriCool Portable Units?
Why Choose AmeriCool Portable Units?

AmeriCool portable cooling solutions deliver powerful, reliable climate control for businesses, factories, server rooms, and industrial spaces. Designed for durability and efficiency, these units provide rapid cooling and heating wherever it’s needed, ensuring a comfortable and controlled environment in any setting.

blockboard tech