Read our privacy policyThe AmeriCool WWC-500 is a 5-ton portable water chiller designed to provide chilled-water circulation for industrial process cooling, equipment temperature control, and other applications requiring a reliable source of chilled water. Combining 61,500 BTU/h of rated cooling capacity with a three-phase scroll compressor, an integrated 1 HP circulation pump, and a design flow rate of 39 GPM, this self-contained chiller provides portable cooling for compatible process equipment and industrial systems. Its wheeled construction, integrated water management features, and onboard diagnostic functions support flexible deployment and simplified operation in demanding industrial environments.
The AmeriCool WWC-500 provides a rated cooling capacity of 61,500 BTU/h, equivalent to approximately 5 tons of refrigeration. Its refrigeration system uses a three-phase scroll compressor and R-410A refrigerant, with a specified refrigerant charge of 130.5 oz (3.7 kg). The manufacturer's owner’s manual specifies a 220V, 60Hz electrical supply, power consumption of 7.05 kW, and current consumption of 18.5 amps. The unit is designed for ambient operating temperatures between 41°F and 113°F and water inlet temperatures between 41°F and 86°F. Rated performance is based on specified test conditions, including an ambient temperature of 95°F at 40% relative humidity and an inlet water temperature of 53.6°F. Actual cooling performance depends on operating conditions, water flow, and the connected thermal load.
The AmeriCool WWC-500 is designed to cool circulating water for compatible industrial processes and equipment. Its integrated 1 HP pump provides a design flow rate of 39 GPM, supporting water circulation between the chiller and the connected application. The onboard controller displays inlet and outlet water temperatures and allows the target temperature to be set within a range of 41°F to 86°F (5°C to 30°C). Cooling operation is controlled according to the difference between the measured water temperature and the target setting. This arrangement provides adjustable chilled-water temperature control for compatible equipment and process loads. Confirm the required water flow, pressure, heat load, and connection configuration before integrating the chiller into a process system.
The AmeriCool WWC-500 features 1-inch supply and return water connections, identified as 25A connections in the manufacturer's owner’s manual. Its integrated 1 HP pump provides a design flow rate of 39 GPM. The unit also incorporates a water drainage connection and a separate water-supply connection for the water-management system. Correct connection of the inlet and outlet lines is essential for proper circulation and cooling operation. The manufacturer specifies that inlet pressure must remain below 0.1 MPa and outlet pressure below 0.6 MPa. Maintain unobstructed water passages, inspect all pipe connections for leakage, and follow the installation instructions for water supply, return, drainage, and pressure limits.
The AmeriCool WWC-500 features a self-contained chiller design with an integrated refrigeration system, circulation pump, controller, and water connections. Its overall dimensions are approximately 26.8 inches wide, 48.8 inches deep, and 52 inches high, with a listed weight of approximately 551 pounds (250 kg). Built-in moving wheels and carrying handles support positioning and handling, while suitable forklift or hoist equipment can be used for lifting when required. The manufacturer instructs users not to tilt the unit more than 40 degrees during movement and specifies that hoisting equipment must be rated to support more than 500 kg. Install the unit in a well-ventilated, low-humidity location, maintain at least 500 mm of clearance around ventilation openings, and provide access to electrical and water connections for operation and maintenance.
The AmeriCool WWC-500 incorporates water-level monitoring and water-management functions to help maintain proper operation of its internal water circuit. AmeriCool's product page describes a built-in water tank and lists a 65-liter tank capacity as an optional specification. The manufacturer also describes an optional automatic water-supply device that replenishes water when the tank level is insufficient. Water-shortage detection helps identify low-water or circulation problems, while the controller provides diagnostic indications for troubleshooting. Before commissioning the chiller, fill the water circuit according to the manufacturer's instructions and verify the correct tank configuration. The manufacturer recommends distilled water or an approved water and antifreeze mixture; follow the specified mixture ratio and fluid requirements to help prevent freezing, contamination, and pump damage.
The AmeriCool WWC-500 includes an electronic controller with power, mode, cooling, and timer functions. The display can show inlet or outlet water temperature, and the target water temperature can be adjusted from 41°F to 86°F (5°C to 30°C). An off-timer can be set from 30 minutes to 12 hours. The controller also incorporates a compressor startup delay of approximately three minutes to help protect the refrigeration system. The manufacturer documents diagnostic indications for reversed phase, compressor overload, water-pump overcurrent, fan-motor overcurrent, insufficient water, high pressure, low refrigerant pressure, abnormal temperature sensors, and antifreeze protection. The owner’s manual specifies a 220V, 60Hz, three-phase electrical supply, 18.5 amps of current consumption, and 7.05 kW of power consumption. Electrical installation must include appropriate grounding, phase verification, circuit protection, and a properly rated dedicated supply in accordance with the manufacturer's wiring diagram and applicable electrical codes.
The AmeriCool WWC-500 is designed for industrial and commercial applications requiring portable chilled-water production, including process equipment cooling, manufacturing operations, industrial machinery, and compatible water-cooled systems. Its 61,500 BTU/h cooling capacity, 39 GPM design flow rate, and adjustable water-temperature control support applications where the process requires a dedicated source of chilled water. The integrated circulation pump reduces the need for a separate external circulation pump for applications within the unit's design limits. Final application suitability depends on the process heat load, required supply-water temperature, system pressure drop, water quality, and actual flow requirements. Verify these parameters before selecting the unit for a specific installation.
The AmeriCool WWC-500 incorporates moving wheels and carrying handles to assist with positioning within an industrial facility. Its weight of approximately 551 pounds requires suitable handling equipment and appropriate procedures during transport and installation. When using a forklift, ensure that the forks are inserted far enough to support the unit securely. When using a hoist, follow the manufacturer's lifting instructions and use equipment rated above 500 kg. Do not tilt the unit more than 40 degrees during movement, and avoid excessive shock or vibration. Once positioned, connect the water supply and return lines, verify the electrical phase sequence, and confirm that the water circuit is filled and free of leaks before starting the chiller.
The AmeriCool WWC-500 supports routine maintenance through its accessible water connections, controller diagnostics, water-level monitoring, and refrigeration-system pressure monitoring. The manufacturer recommends cleaning the condenser fins using an air gun or brush while taking care not to bend or damage the fins. Keep the condenser surface free from dust and oil mist, and ensure that ventilation openings remain unobstructed. Before performing maintenance, disconnect the electrical supply and ensure the machine is not operating. Drain the remaining water from the unit before extended storage, and keep the unit in a suitable location away from excessive heat and humidity. Regularly inspect the water piping, valves, and connections for leaks, and replace contaminated water as directed by the manufacturer. Use the diagnostic codes in the owner’s manual to identify operating issues and contact qualified service personnel for refrigeration or electrical repairs.
The AmeriCool WWC-500 is supplied with manufacturer warranty coverage subject to the applicable limited-warranty terms, conditions, and exclusions. The owner’s manual directs customers to retain purchase documentation and provide the unit's serial number, purchase details, and operating information when requesting service. Confirm the exact warranty duration and coverage for parts, labor, and the compressor using the warranty documentation supplied with the specific unit or obtained directly from AmeriCool.
Experience flexible process cooling with the AmeriCool WWC-500 portable water chiller. Combining 61,500 BTU/h of rated cooling capacity with a three-phase scroll compressor, an integrated 1 HP circulation pump, a 39 GPM design flow rate, and adjustable chilled-water temperature control, this 5-ton chiller provides a portable cooling solution for compatible industrial processes, manufacturing equipment, and commercial applications requiring dependable chilled-water circulation.
All AmeriCool commercial unit sales are final and are non-refundable.
All AmeriCool commercial unit sales are final and are non-refundable.