0% Financing for 12 Months* or up to 48 Months* Terms Available - Buy Now and Pay later!

Carrier Gemini 7.5 Ton 11.2 EER Heat Pump and Multi-Positional Air Handler System | 208/230V 3 Phase - R454B - Two Stage

Required Fields *

By

Carrier

In stock

Model

38AXQM08A0A5-0A0A0 / 40RLQA08A2A5-0A0A0

ID

245288

Your Low Price $18,499.00
Ships in 1-2 Weeks
Free Shipping
 
Product Features
  • Completed Heat Pump System
  • Precharged with R32 Refrigerant
  • Multi-Positional System Orientation
  • 208/230V 3 Phase
  • Heat Kits Ranging from 3kW to 25kW's available
  • Up to a 10-Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

Customize Carrier Gemini 7.5 Ton 11.2 EER Heat Pump and Multi-Positional Air Handler System | 208/230V 3 Phase - R454B - Two Stage
Carrier Gemini 7.5 Ton 11.2 EER Heat Pump Outdoor Unit Split System | 208/230V 3 Phase - R454B - Two Stage
Carrier Gemini 7.5 Ton 11.2 EER Heat Pump Outdoor Unit Split System | 208/230V 3 Phase - R454B - Two Stage
Carrier Gemini 7.5 Ton 11.2 EER Heat Pump Outdoor Unit Split System | 208/230V 3 Phase - R454B - Two Stage   + $10,999.00
Carrier Gemini 7.5 Ton Packaged Air-Handler Unit | 208/230V 3 Phase - R454B - Two Stage
Carrier Gemini 7.5 Ton Packaged Air-Handler Unit | 208/230V 3 Phase - R454B - Two Stage
Carrier Gemini 7.5 Ton Packaged Air-Handler Unit | 208/230V 3 Phase - R454B - Two Stage   + $7,500.00
Carrier Gemini 7.5 Ton 11.2 EER Heat Pump and Multi-Positional Air Handler System | 208/230V 3 Phase - R454B - Two Stage - 38AXQM08A0A5-0A0A0 / 40RLQA08A2A5-0A0A0

$18,499.00

Reliable Year-Round Comfort with a 7.5-Ton Commercial Split Heat Pump System for Light Commercial Applications

The Carrier 38AXQM08A0A5-0A0A0 / 40RLQA08A2A5-0A0A0 is a nominal 7.5-ton commercial split heat pump system designed to provide year-round heating and cooling for suitable ducted applications. Combining the 38AXQM08A0A5 outdoor heat pump with the 40RLQA08A2A5 indoor air handler, this system features a scroll compressor, two-stage cooling, Puron Advance™ R-454B refrigerant, and a two-speed direct-drive EcoBlue™ vane axial fan. The indoor unit features a medium-static-pressure configuration and a factory-installed thermal expansion valve (TXV) for refrigerant flow control. Both units are designed for 208/230V three-phase, 60 Hz electrical service. The Carrier Gemini® commercial split-system platform combines flexible installation options, advanced refrigeration technology, and commercial-grade construction for dependable indoor comfort. Final equipment compatibility, electrical requirements, and matched-system performance should be confirmed using Carrier's approved technical documentation.

Key Benefits

  • 7.5-Ton Commercial Capacity – Provides nominal 90,000 BTU/h heating and cooling capacity to support appropriately sized commercial and light commercial applications.
  • Two-Stage Cooling Performance – The outdoor unit features a single-circuit, two-stage cooling configuration designed to accommodate varying cooling demands.
  • Year-Round Heat Pump Operation – Reversible heat pump technology provides both heating and cooling through one outdoor system.
  • R-454B Refrigerant Technology – Uses Puron Advance™ R-454B refrigerant, a lower-global-warming-potential refrigerant designed for newer-generation commercial HVAC equipment.
  • Scroll Compressor Technology – The scroll compressor supports dependable refrigeration operation and commercial cooling performance.
  • Two-Speed EcoBlue™ Fan – The indoor air handler features a direct-drive, two-speed vane axial fan to support ducted air distribution.
  • Medium-Static-Pressure Configuration – The indoor air handler is designed for medium-static duct applications, providing flexibility for suitable commercial air distribution systems.
  • Factory-Installed TXV – The indoor air handler incorporates a thermal expansion valve to regulate refrigerant flow according to system operating conditions.
  • Enhanced Equipment Protection – Standard outdoor-unit features include high- and low-pressure switches, compressor overload protection, and anti-short-cycling protection.
  • Flexible Installation – The outdoor unit supports approved ground-level or rooftop mounting configurations, providing options for different commercial building layouts.
  • A2L Refrigerant Safety Features – The 40RLQ indoor air handler incorporates an onboard refrigerant dissipation system designed for use with R-454B refrigerant.

Reliable Heat Pump Heating for Year-Round Comfort

The Carrier 38AXQM08A0A5-0A0A0 provides nominal 7.5-ton heat pump capacity for commercial heating applications. Its reversible refrigeration circuit transfers heat into the indoor space during heating mode, providing an alternative to conventional electric resistance heating. According to Carrier's published 38AXQ/40RLQ product-family performance data, the nominal 7.5-ton equipment combination provides a net heating capacity of 88,000 BTU/h at 47°F outdoor temperature, with a coefficient of performance (COP) of 3.50. At 17°F outdoor temperature, the published net heating capacity is 54,000 BTU/h, with a COP of 2.40. These values represent specified product-family rating conditions and should be confirmed against the exact approved equipment configuration. The heat pump's heating performance varies according to outdoor temperature, indoor airflow, refrigerant conditions, and installation requirements. Supplemental heating provisions, where required, should be selected according to the building's heating load and applicable equipment documentation.

7.5-Ton Cooling Performance for Commercial Comfort

The Carrier 38AXQM08A0A5-0A0A0 outdoor heat pump delivers nominal 7.5-ton cooling capacity, equivalent to approximately 90,000 BTU/h. Carrier's published 38AXQ08/40RLQ08 performance data lists a net cooling capacity of 92,000 BTU/h under specified rating conditions. The system features a single-circuit refrigeration design with a two-stage scroll compressor configuration to support changing cooling requirements. The published performance data identifies an EER of 11.2 and an integrated energy efficiency ratio (IEER) of 15.3 for the 7.5-ton 38AXQ/40RLQ equipment combination. These commercial efficiency ratings are based on the manufacturer's specified testing conditions and should not be confused with residential SEER2 ratings. Actual cooling performance depends on equipment matching, indoor airflow, duct design, refrigerant charge, outdoor conditions, and installation quality.

Energy Efficiency and Refrigeration Technology

The Carrier 38AXQ commercial heat pump series combines scroll compressor technology with a refrigeration circuit engineered for dependable commercial operation. The 38AXQM08A0A5-0A0A0 features a single-circuit, two-stage cooling configuration and uses Puron Advance™ R-454B refrigerant. Its refrigeration system incorporates protective features including high- and low-pressure switches, compressor overload protection, and anti-short-cycling protection. The outdoor unit also features a standard crankcase heater and compressor vibration isolation to support reliable operation. The 40RLQA08A2A5-0A0A0 indoor air handler complements the outdoor equipment with a factory-installed TXV and a two-speed direct-drive EcoBlue™ vane axial fan. Carrier's published performance information identifies an IEER of 15.3 and an EER of 11.2 for the nominal 7.5-ton 38AXQ/40RLQ configuration. These ratings should be distinguished from independently verified performance for the exact installed model combination.

Split-System Design for Flexible Installation

The split-system configuration separates the 38AXQM08A0A5-0A0A0 outdoor heat pump from the 40RLQA08A2A5-0A0A0 indoor air handler, providing flexibility in equipment placement and duct routing. The outdoor unit features a prepainted galvanized steel cabinet designed to withstand demanding commercial installation environments. Its perimeter base rail incorporates forklift slots and lifting holes to facilitate equipment handling and installation. The unit is suitable for approved ground-mounted or rooftop installations. The 40RLQ indoor air handler features a medium-static-pressure configuration and a two-speed direct-drive vane axial fan designed for compatible ducted applications. Refrigerant piping, electrical connections, condensate drainage, equipment clearances, and mounting requirements must follow Carrier's approved installation instructions. The system must also be configured with the appropriate R-454B refrigerant safety provisions and compatible indoor equipment.

Controls and Indoor Comfort

The Carrier 38AXQ and 40RLQ system uses compatible commercial heat pump controls to coordinate heating, cooling, compressor operation, and indoor fan performance. The outdoor unit features a 24V control circuit transformer to facilitate compatible thermostat and control wiring. Its two-stage cooling configuration supports operation at different cooling capacities according to system demand. The 40RLQA08A2A5-0A0A0 indoor air handler incorporates a two-speed direct-drive EcoBlue™ vane axial fan to provide airflow adjustment for suitable ducted applications. Its factory-installed TXV regulates refrigerant flow, supporting appropriate refrigeration operation during heating and cooling. The indoor unit also incorporates an onboard A2L refrigerant dissipation system designed for use with the R-454B refrigerant circuit. Thermostat selection, control wiring, fan operation, and refrigerant safety provisions must be verified against Carrier's technical documentation for the exact equipment configuration.

Commercial and Ducted Applications

The Carrier 38AXQM08A0A5-0A0A0 / 40RLQA08A2A5-0A0A0 combination provides nominal 7.5-ton heating and cooling capacity for appropriately designed commercial ducted applications. Potential applications include offices, retail establishments, commercial buildings, and other suitable conditioned spaces requiring higher-capacity split-system heating and cooling. The outdoor heat pump and indoor air handler are designed for 208/230V three-phase, 60 Hz electrical service. The outdoor unit's electrical requirements, including minimum circuit ampacity and maximum overcurrent protection, must be verified against its equipment nameplate and approved installation documentation. The indoor unit's electrical requirements must likewise be checked independently. Proper equipment sizing, duct static pressure, airflow, ventilation, electrical supply, and refrigerant piping are essential to achieving the intended system performance. Confirm the exact outdoor and indoor model pairing as an approved Carrier configuration before installation.

Serviceability and Maintenance

The Carrier 38AXQ commercial heat pump includes several features designed to support routine inspection and servicing. Standard protective components include high- and low-pressure switches, compressor overload protection, anti-short-cycling protection, and a Comfort Alert™ diagnostic board. The outdoor unit also features an accessible compressor compartment, a non-fused disconnect switch, and a galvanized steel cabinet designed for commercial environments. The indoor 40RLQ air handler incorporates an onboard A2L refrigerant dissipation system as part of its R-454B safety design. Routine maintenance should include inspection and cleaning of indoor and outdoor coils, air filter inspection, condensate drainage checks, electrical connection inspection, and verification of refrigerant-system operation. Qualified HVAC personnel should perform refrigerant-related service, electrical testing, and safety-system inspections according to Carrier's maintenance and service recommendations.

Warranty

The Carrier 38AXQ commercial heat pump series includes a standard limited warranty covering the compressor for 5 years on parts and other parts for 1 year, according to Carrier's published product specifications. Warranty coverage is subject to applicable registration requirements, installation conditions, product eligibility, and the manufacturer's complete warranty terms. Separate warranty provisions may apply to the 40RLQ indoor air handler. Confirm the warranty coverage for both equipment components, including registration requirements and applicable exclusions, before purchase and installation. Refer to Carrier's official commercial equipment warranty documentation for complete details.

Recommended Accessories

  • Compatible Commercial Heat Pump Thermostat – Select a commercial thermostat approved for the Carrier 38AXQ two-stage cooling and heat pump control configuration.
  • Compatible Refrigerant Piping – Select and size the R-454B-compatible refrigerant line set according to Carrier's approved piping requirements and actual installation conditions.
  • Outdoor Equipment Pad or Rooftop Support – Provide a suitable mounting platform or structural support designed for the outdoor unit's operating weight and installation environment.
  • Electrical Disconnect and Overcurrent Protection – Select electrical components according to the individual equipment nameplates, installation instructions, and applicable electrical codes.
  • Duct Transitions and Air Distribution Components – Select appropriately sized supply and return duct transitions, fittings, and distribution components for the indoor air handler's medium-static-pressure configuration.
  • Condensate Drainage Components – Provide suitable drain piping, fittings, and condensate management accessories for the indoor air handler installation.
  • R-454B Refrigerant Service Equipment – Use approved refrigerant recovery, charging, leak-detection, and service equipment suitable for A2L refrigerant applications.

Dependable Commercial Heating and Cooling with the Carrier 38AXQM08A0A5-0A0A0 / 40RLQA08A2A5-0A0A0

Support dependable year-round indoor comfort with the Carrier 38AXQM08A0A5-0A0A0 / 40RLQA08A2A5-0A0A0 commercial split heat pump system. Combining nominal 7.5-ton heating and cooling capacity, a two-stage scroll compressor configuration, Puron Advance™ R-454B refrigerant, and a medium-static indoor air handler with a two-speed EcoBlue™ vane axial fan, this system offers a flexible commercial ducted heating and cooling solution. With commercial-grade construction, integrated equipment protection, and an onboard A2L refrigerant dissipation system, the Carrier 38AXQ/40RLQ platform is designed to support reliable operation in suitable commercial applications when properly matched, installed, and maintained.

More Information
Carrier Gemini 7.5 Ton 11.2 EER Heat Pump Outdoor Unit Split System | 208/230V 3 Phase - R454B - Two Stage
FeatureSpec
SKU38AXQM08A0A5-0A0A0
Weight (in lbs)523
Brand/ManufacturerCarrier
Cooling BTU92,000 BTU
Heating BTU88,000 BTU
Blower Motor2 Speed
Maximum CFM3,000
Decibel Level (dBA)86.8
Motor RPM1,100
Horsepower1/4 HP
RefrigerantR454B
EER11.2
Condenser StagesTwo Stage
Compressor TypeScroll
Liquid Line1/2"
Suction Line1 1/8"
Electrical208/230V 3 Phase 60Hz
PhaseThree Phase
Max Breaker Size60 Amps
Min. Breaker Size26.3 Amps
Tonnage7.5 Ton
Height50.37"
Width46"
Depth59.25"
WarrantyUp to 4 Years Limited Warranty with Online Registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Carrier Gemini 7.5 Ton Packaged Air-Handler Unit | 208/230V 3 Phase - R454B - Two Stage
FeatureSpec
SKU40RLQA08A2A5-0A0A0
Weight (in lbs)385
Brand/ManufacturerCarrier
Cooling BTU88,000 BTU
Heating BTU54,000 BTU
Blower Motor2 Speed
Drive TypeEC Motor
Maximum CFM3,000
Motor RPM2,000
Horsepower2 2/5 HP
RefrigerantR454B
Condenser StagesTwo Stage
Compressor TypeScroll
Liquid Line5/8"
Suction Line1 1/8"
Electrical208/230V 3 Phase 60Hz
PhaseThree Phase
Max Breaker Size15 Amps
Tonnage7.5 Ton
Height56.06"
Width49"
Depth28.18"
WarrantyUp to 4 Years Limited Warranty with Online Registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Carrier Gemini 7.5 Ton 11.2 EER Heat Pump and Multi-Positional Air Handler System | 208/230V 3 Phase - R454B - Two Stage
Your Rating
Customer Questions
No Questions
Did you find what you were looking for?
blockboard tech