In stock
Call 800-397-1392 for Best Prices!
The Carrier 38AXQM08A0A6-0A0A0 / 40RLQA08A2A6-0A0A0 is a nominal 7.5-ton commercial split heat pump and air handler system designed to provide year-round heating and cooling for suitable ducted applications. Combining the 38AXQM08A0A6 outdoor heat pump with the 40RLQA08A2A6 indoor air handler, this system features a scroll compressor, two-stage cooling, Puron Advance™ R-454B refrigerant, and a two-speed direct-drive EcoBlue™ vane axial fan. The indoor air handler features a medium-static-pressure configuration and a factory-installed thermal expansion valve (TXV) for refrigerant flow control. Both units are designed for 460V three-phase, 60 Hz electrical service. The Carrier Gemini® commercial split-system platform combines flexible installation options, advanced refrigeration technology, and commercial-grade construction for dependable indoor comfort. Final equipment compatibility, electrical requirements, and matched-system performance should be confirmed using Carrier's approved technical documentation.
The Carrier 38AXQM08A0A6-0A0A0 provides nominal 7.5-ton heat pump capacity for commercial heating applications. Its reversible refrigeration circuit transfers heat into the indoor space during heating mode, providing an alternative to conventional electric resistance heating. According to Carrier's published 38AXQ/40RLQ product-family performance data, the nominal 7.5-ton equipment combination provides a net heating capacity of 88,000 BTU/h at 47°F outdoor temperature, with a coefficient of performance (COP) of 3.50. At 17°F outdoor temperature, the published net heating capacity is 54,000 BTU/h, with a COP of 2.40. These values represent specified manufacturer rating conditions for the 38AXQ08/40RLQ08 equipment combination. The heat pump's heating performance varies according to outdoor temperature, indoor airflow, refrigerant conditions, and installation requirements. Supplemental heating provisions, where required, should be selected according to the building's heating load and applicable Carrier documentation.
The Carrier 38AXQM08A0A6-0A0A0 outdoor heat pump delivers nominal 7.5-ton cooling capacity, equivalent to approximately 90,000 BTU/h. Carrier's published 38AXQ08/40RLQ08 performance data lists a net cooling capacity of 92,000 BTU/h under specified rating conditions. The system features a single-circuit refrigeration design with a two-stage cooling configuration to support changing cooling requirements. Published performance data identifies an Energy Efficiency Ratio (EER) of 11.2 and an Integrated Energy Efficiency Ratio (IEER) of 15.3 for the nominal 7.5-ton 38AXQ/40RLQ equipment combination. These commercial efficiency ratings are based on the manufacturer's specified testing conditions and should not be confused with residential SEER2 ratings. Actual cooling performance depends on equipment matching, indoor airflow, duct design, refrigerant charge, outdoor conditions, and installation quality.
The Carrier 38AXQ commercial heat pump series combines scroll compressor technology with a refrigeration circuit engineered for dependable commercial operation. The 38AXQM08A0A6-0A0A0 features a single-circuit, two-stage cooling configuration and uses Puron Advance™ R-454B refrigerant. Its refrigeration system incorporates protective features including high- and low-pressure switches, compressor overload protection, and anti-short-cycling protection. The outdoor unit also features a standard crankcase heater and compressor vibration isolation to support reliable operation. The 40RLQA08A2A6-0A0A0 indoor air handler complements the outdoor heat pump with a factory-installed TXV, a direct-expansion evaporator coil, and a two-speed direct-drive EcoBlue™ vane axial fan. Carrier's published performance information identifies an IEER of 15.3 and an EER of 11.2 for the nominal 7.5-ton 38AXQ/40RLQ configuration. These ratings are based on the manufacturer's specified matched equipment configuration and testing conditions.
The split-system configuration separates the 38AXQM08A0A6-0A0A0 outdoor heat pump from the 40RLQA08A2A6-0A0A0 indoor air handler, providing flexibility in equipment placement and duct routing. The outdoor unit features a prepainted galvanized steel cabinet designed for demanding commercial installation environments. Its perimeter base rail incorporates forklift slots and lifting holes to facilitate equipment handling and installation. The unit supports approved ground-mounted or rooftop installations. The 40RLQ indoor air handler features a medium-static-pressure configuration and a two-speed direct-drive vane axial fan designed for compatible ducted applications. Both units are rated for 460V three-phase electrical service. Refrigerant piping, electrical connections, condensate drainage, equipment clearances, and mounting requirements must follow Carrier's approved installation instructions. The system must also be configured with the appropriate R-454B refrigerant safety provisions and approved equipment combination.
The Carrier 38AXQ and 40RLQ system uses compatible commercial heat pump controls to coordinate heating, cooling, compressor operation, and indoor fan performance. The outdoor unit features a 24V control circuit transformer to facilitate compatible thermostat and control wiring. Its two-stage cooling configuration supports operation at different cooling capacities according to system demand. The 40RLQA08A2A6-0A0A0 indoor air handler incorporates a two-speed direct-drive EcoBlue™ vane axial fan to provide airflow adjustment for suitable ducted applications. Its factory-installed TXV regulates refrigerant flow, supporting appropriate refrigeration operation during heating and cooling. The indoor unit also incorporates a factory-installed A2L refrigerant detection and dissipation system designed for use with the R-454B refrigerant circuit. Thermostat selection, control wiring, fan operation, and refrigerant safety provisions must be verified against Carrier's technical documentation for the exact equipment configuration.
The Carrier 38AXQM08A0A6-0A0A0 / 40RLQA08A2A6-0A0A0 combination provides nominal 7.5-ton heating and cooling capacity for appropriately designed commercial ducted applications. Potential applications include offices, retail establishments, commercial buildings, and other suitable conditioned spaces requiring higher-capacity split-system heating and cooling. Both the outdoor heat pump and indoor air handler operate on 460V three-phase, 60 Hz electrical service. The outdoor unit's electrical requirements, including minimum circuit ampacity and maximum overcurrent protection, must be verified against its equipment nameplate and approved installation documentation. The indoor air handler's electrical requirements must likewise be checked independently. Proper equipment sizing, duct static pressure, airflow, ventilation, electrical supply, and refrigerant piping are essential to achieving the intended system performance. Confirm the exact outdoor and indoor model pairing as an approved Carrier configuration before installation.
The Carrier 38AXQ commercial heat pump includes several features designed to support routine inspection and servicing. Standard protective components include high- and low-pressure switches, compressor overload protection, anti-short-cycling protection, and a Comfort Alert™ diagnostic board. The outdoor unit also features an accessible compressor compartment, a non-fused disconnect switch, and a galvanized steel cabinet designed for commercial environments. The indoor 40RLQ air handler incorporates a factory-installed A2L refrigerant detection and dissipation system as part of its R-454B safety design. Routine maintenance should include inspection and cleaning of indoor and outdoor coils, air filter inspection, condensate drainage checks, electrical connection inspection, and verification of refrigerant-system operation. Qualified HVAC personnel should perform refrigerant-related service, electrical testing, and refrigerant safety-system inspections according to Carrier's maintenance and service recommendations.
The Carrier 38AXQ commercial heat pump series includes a standard limited warranty covering the compressor for 5 years on parts and other parts for 1 year, according to Carrier's published product specifications. Warranty coverage is subject to applicable registration requirements, installation conditions, product eligibility, and the manufacturer's complete warranty terms. Separate warranty provisions may apply to the 40RLQ indoor air handler. Confirm the warranty coverage for both equipment components, including registration requirements and applicable exclusions, before purchase and installation. Refer to Carrier's official commercial equipment warranty documentation for complete details.
Support dependable year-round indoor comfort with the Carrier 38AXQM08A0A6-0A0A0 / 40RLQA08A2A6-0A0A0 commercial split heat pump and air handler system. Combining nominal 7.5-ton heating and cooling capacity, a two-stage scroll compressor configuration, Puron Advance™ R-454B refrigerant, and a medium-static indoor air handler with a two-speed EcoBlue™ vane axial fan, this system offers a flexible commercial ducted heating and cooling solution. With commercial-grade construction, integrated equipment protection, factory-installed A2L refrigerant safety technology, and matching 460V three-phase electrical requirements, the Carrier 38AXQ/40RLQ platform is designed to support reliable operation in suitable commercial applications when properly matched, installed, and maintained.