Daikin 3 Ton 14 SEER2 Light Commercial Packaged Air Conditioner | 208/230V 1 Phase - R32 - Single Stage

Daikin 3 Ton 14 SEER2 Light Commercial Packaged Air Conditioner | 208/230V 1 Phase - R32 - Single Stage
By

Daikin

In stock
Model

DSC0361D000001S

ID

190724

Was $4,726.67 Your Low Price Special Price $3,545.00
ONLY 1 LEFT!
Free Shipping
 
Product Features
  • Designed for Easy Retrofit Installs
  • Custom Roof Curbs designed to fit your current adapter!
  • Precharged with R32 Refrigerant
  • Single Stage Condenser
  • 208/230V 1 Phase
  • Up to a 5 Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

Efficient 3-Ton Air Conditioner Rooftop Unit for Light Commercial Applications with Direct-Drive Supply Fan

The Daikin DSC0361D000001S is a 3-ton commercial packaged air conditioner designed to provide reliable, efficient cooling for light commercial applications. Combining 36,000 BTU/h of cooling capacity with a direct-drive supply fan and convertible airflow configuration, this all-in-one rooftop system helps deliver dependable cooling while simplifying installation and preserving valuable indoor space.

Key Benefits

  • 14 SEER2 / 12 EER2 Efficiency – Provides efficient cooling performance to help manage energy use during warm-weather operation.
  • 36,000 BTU/h Cooling Capacity – Delivers cooling capacity suited to a range of light commercial applications.
  • High-Performance Scroll Compressor – Provides reliable cooling performance with a compressor design engineered for commercial packaged air conditioning.
  • Direct-Drive Supply Fan – Eliminates belt-driven components and provides efficient, quiet air movement with airflow control across a range of static pressures.
  • Packaged Rooftop Configuration – Combines major air conditioning components in one outdoor unit to simplify equipment placement and preserve indoor floor space.
  • Galvanized Steel Cabinet – Heavy-gauge galvanized-steel construction with a UV-resistant powder-paint finish provides durability and corrosion resistance.
  • Convertible Airflow Orientation – Supports downflow or horizontal applications for greater installation flexibility.
  • Tool-Less Filter Access – Provides convenient access to the filter section to simplify routine maintenance.

Daikin Air Conditioner Commercial Rooftop Units

Discover the advantages of Daikin R-32 Commercial Packaged Air Conditioners, designed to deliver reliable cooling, energy-efficient performance, and lasting durability.

Featured advanced HVAC technology and environmentally conscious R-32 refrigerant, these commercial rooftop units offer a lower-GWP alternative to traditional R-410A systems.

Their all-in-one design and service-friendly components help simplify installation and ongoing maintenance for contractors and building owners.

Whether upgrading existing equipment or planning a new installation, Daikin provides innovative commercial cooling solutions built for dependable performance.

Watch the video to learn more about what makes Daikin a trusted choice for Commercial HVAC.


R-32 Refrigerant – Primary Cooling Benefit

The integrated air conditioning system uses R-32 chlorine-free refrigerant and a high-performance scroll compressor to provide 36,000 BTU/h of total cooling capacity. The refrigerant circuit is designed for reliable comfort cooling in normal heating, ventilating, and air conditioning applications, while the packaged configuration integrates the cooling components into a single rooftop system.

36,000 BTU/h Cooling Performance

The DSC0361D000001S provides 36,000 BTU/h of nominal cooling capacity with a 14 SEER2 and 12 EER2 efficiency rating. This combination helps provide dependable commercial cooling performance while supporting efficient operation during warm-weather conditions.

Efficient Direct-Drive Operation

With 14 SEER2 and 12 EER2 efficiency ratings and a direct-drive supply fan, this system is designed to provide efficient air movement and cooling performance. The supply fan uses an airfoil single-width, single-inlet Class II construction with aluminum fan blades to provide efficient and quiet operation across a wide range of static pressure and airflow requirements.

Packaged Rooftop Installation Design

The packaged rooftop configuration combines the compressor, condenser, evaporator coil, supply fan, controls, and other air distribution components into a single outdoor unit, helping simplify equipment placement and preserve valuable indoor space. Daikin designed the packaged units for fast and easy installation in new construction and retrofit projects, and the units are built to be a direct replacement for most rooftop units without requiring a curb adapter. The DSC0361D000001S supports convertible downflow or horizontal airflow configurations.

Controls & Comfort

The DSC0361D000001S is equipped with a 24-volt electromechanical controls package for commercial system operation. The unit's direct-drive supply fan provides airflow control for varying static pressure and airflow requirements, while the convertible airflow configuration allows the unit to accommodate either downflow or horizontal applications.

Commercial Applications

The Daikin DSC0361D000001S is designed for comfort cooling applications in light commercial buildings and other normal heating, ventilating, and air conditioning environments. Its compact packaged rooftop design, convertible airflow orientation, direct-drive supply fan, and retrofit-friendly configuration make it well suited for applications where reliable cooling and installation flexibility are important.

Service & Maintenance

The DSC0361D000001S is designed for convenient service access, including tool-less filter access for routine filter maintenance. Screw-on style pressure switches are designed for ease of replacement, while the factory-wired and tested electrical system helps support faster commissioning and start-up. The unit also includes a factory-installed filter drier as part of the standard packaged air conditioning system.

Warranty

The Daikin DSC0361D000001S includes a 5-Year Parts Limited Warranty. Complete warranty details, including applicable terms and conditions, are available from the Daikin distributor or manufacturer's representative.

Recommended Accessories

Reliable Commercial Cooling with the Daikin DSC0361D000001S

Experience reliable, efficient commercial cooling with the Daikin DSC0361D000001S. Combining R-32 refrigerant, high-performance scroll compressor technology, direct-drive air distribution, and flexible downflow or horizontal airflow configuration in one packaged rooftop air conditioning system.

More Information
Daikin 3 Ton 14 SEER2 Light Commercial Packaged Air Conditioner | 208/230V 1 Phase - R32 - Single Stage
FeatureSpec
SKUDSC0361D000001S
Refrigerant ChargePre-charged
Weight (in lbs)484
AHRI Certificate Number215414886
Brand/ManufacturerDaikin
ReplacesDFC0361D000001S
UPC633190262875
Cooling BTU35,000 BTU
Drive TypeDirect
Maximum CFM1160
Decibel Level (dBA)78 decibels
RefrigerantR32
SEER2 (Efficiency)14
EER212
Condenser StagesSingle Stage
Compressor TypeScroll
Electrical208 / 230 V. 1 Phase 60 Hz
PhaseSingle Phase
Max Breaker Size40 amps
Min. Breaker Size27.2 amps
Tonnage3 Ton
Height38.8"
Width73.9"
Depth48.1"
Warranty5 Years with Online Registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Daikin 3 Ton 14 SEER2 Light Commercial Packaged Air Conditioner | 208/230V 1 Phase - R32 - Single Stage
Your Rating
Customer Questions
What does BTU and Tonnage Mean?
BTU (British Thermal Unit) measures the amount of heating or cooling energy a commercial rooftop packaged unit can produce per hour, while tonnage measures the unit's nominal cooling capacity. One ton of cooling equals 12,000 BTU/h, meaning a 10-ton commercial rooftop unit provides approximately 120,000 BTU/h of cooling capacity. Both measurements help contractors and customers determine the appropriate HVAC system size and output for a building's heating and cooling requirements.
What accessories or additional components are needed to install a Commercial Rooftop Units?
Installing a commercial rooftop unit may require several accessories and additional components depending on the building's existing setup and installation requirements. Common components include a roof curb or curb adapter, ductwork transitions, electrical disconnects, thermostats, economizers, dampers, and supplemental heating kits when applicable. Additional accessories, such as hail guards, smoke detectors, and condensate drain components, may also be recommended based on the application. Always verify equipment compatibility and manufacturer installation requirements before purchasing additional components.
Can I replace my existing Commercial Rooftop Unit without replacing the ductwork?
Yes. In many cases, an existing commercial rooftop unit can be replaced without replacing the current ductwork, provided the duct system is in good condition and compatible with the new equipment. Before installation, an HVAC professional should evaluate the ductwork, airflow requirements, unit capacity, and existing connections to ensure proper system performance. Additional modifications may be necessary if the new unit has different dimensions, airflow configurations, or connection requirements.
How efficient is a Commercial Air Conditioner Packaged Rooftop Unit?
The typical efficiency of a Commercial AC-Only Rooftop Packaged Unit varies by model, size, and manufacturer, with IEER ratings generally ranging from approximately 13 to 20 or higher. Efficiency is measured using EER (Energy Efficiency Ratio) and IEER (Integrated Energy Efficiency Ratio), with higher ratings indicating greater cooling efficiency and potentially lower electricity costs. Actual efficiency ratings should be verified using the manufacturer's specifications for each model.
What is the average life expectancy of a Commercial Air Conditioner Rooftop Packaged unit?
The average life expectancy of a commercial AC rooftop packaged unit is approximately 15–20 years. Actual lifespan depends on factors such as installation quality, operating conditions, usage, and routine preventative maintenance. Regular professional servicing, filter replacements, and keeping coils and components clean can help extend the system's lifespan and maintain reliable performance.
What are the Commercial Rooftop Air Conditioner efficiency ratings and what do they mean?
Commercial rooftop air conditioner efficiency ratings measure how effectively a unit converts electricity into cooling output. Common ratings include SEER2 (Seasonal Energy Efficiency Ratio 2), which measures seasonal cooling efficiency, and EER2 (Energy Efficiency Ratio 2), which measures cooling efficiency under specific operating conditions. Higher efficiency ratings generally indicate lower energy consumption and reduced operating costs. When comparing commercial rooftop AC units, consider both efficiency ratings, cooling capacity, building requirements, and expected usage to determine the best fit for your application.
Does a Commercial Air Conditioner Rooftop Packaged Unit provide heating?
A commercial AC rooftop packaged unit is primarily designed to provide cooling and does not typically include built-in heating capabilities. However, some models offer optional electric heat kits that provide supplemental heating when needed. If both heating and cooling are required, a commercial gas/electric packaged unit or rooftop heat pump may be a better solution.
What is the difference between single-stage, two-stage, and variable-speed Commercial Air Conditioners?
The difference between single-stage, two-stage, and variable-speed commercial air conditioners is how they adjust cooling output to meet a building's temperature demands. Single-stage units operate at one fixed cooling capacity, running at full output whenever cooling is needed. Two-stage units offer high and low cooling settings, allowing them to adjust output based on demand for improved temperature control and efficiency. Variable-speed units can continuously adjust compressor and airflow output to better match changing cooling requirements, providing more consistent temperatures, improved humidity control, and potentially greater energy efficiency.
Did you find what you were looking for?
blockboard tech