Thermostatic Expansion Valves (TXVs) are:

  • A requirement for 14 SEER or higher split system heat pumps
  • A requirement for many condensers or heat pump systems that use the new R-410A refrigerant
  • An optional upgrade for any other air conditioner or heat pump system

Your system will operate more precisely and with greater efficiency with a TXV. These valves offer more control over how much liquid refrigerant enters the evaporator coil. The valves only allow a precise amount of liquid into the evaporator coil to ensure that all liquid that enters fully evaporates. This prevents too little liquid from entering the evaporator making the system run less efficiently. It also prevents too much liquid from entering the evaporator which can cause excess liquid in the suction line. Thermostatic Expansion Valves can be mounted in any position on the evaporator coil inlet and are reliable, efficient and virtually trouble-free. Select the TXV to correspond with the tonnage of your air conditioner or heat pump, as well as to match the type of refrigerant your systems uses, R-22 (standard) or R-410A (new alternative). 

When using a TXV, manufacturer's recommend also installing a hard-start capacitor in your heat pump or condenser. This capacitor gives an extra "jolt" of electricity upon startup to push the refrigerant against higher head pressures that are present with a TXV system. If a hard-start capacitor isn't installed, the equipment compressor may sometimes have difficulty starting.

Compatibility

Please note that this is not an exhaustive list. Use Ctrl+F to simplify your search. This part is compatible with the following models:

GSX160601 GSX160611

More Information
Goodman 5 Ton Fixed TXV Kit - R-410A
FeatureSpec
SKUTXV-60
Weight (in lbs)2.5
UPCna
RefrigerantR410A
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Goodman 5 Ton Fixed TXV Kit - R-410A
Your Rating
Customer Questions
Is this a direct replacement and compatible with goodman avptc61d14 air handler and gsz160601bd condenser?
AVPTC model air handlers come with a TXV kit pre-installed (this is what the "T" in AVPTC stands for). If a different brand of TXV kit instead of the Goodman one that comes standard with the air handler is currently installed, then this is something that cannot easily be helped through our FAQ system. Our salespeople will be able to help you out here - each of them are extremely knowledgeable in HVAC and can help you figure out if the TXV-60 can replace your Sporlan one. Please give us a call and our sales team will help you find a solution.
What is the correct positioning for the sensing bulb in evaporator coil for this TXV?
The bulb typically goes on the coil or on the line set itself by the coil. If you have any further questions, please call us and we will be happy to assist you.
What TXV do I need for goodman ASPT49D14AC? 5 ton and is it currently in stock? Thanks
A TXV is already built into the ASPT49D14AC. If this is for replacing that TXV due to an issue of some sort, the replacement TXV model number is 0151R00133. While we don't have it available on our site, we can still get the part ordered for you through our Part Quote Request form (https://hvacdirect.com/part-quote) located in the Helpful Links section at the bottom of our website. After submitting the form, a member of our parts department will reach out to you about the replacement TXV you need. If you have any further questions, please call us and we will be happy to assist you.