Koldwave 5 Ton 60,000 BTU Air-Cooled Portable Air Conditioner Industrial Horizontal | 220V - R32

SAVE $12,106.01
By

Koldwave

In stock
Model

K8HK60BF

ID

233031

Was $28,739.00 Your Low Price Special Price $16,632.99
Ships In 1-3 Business Days
Free Shipping
 
Product Features
  • Durable all-steel painted cabinet
  • Built-in thermostat for precise temperature control
  • Fiberglass-insulated for quiet, efficient operation
  • Uses R32 refrigerant for reliable cooling

Efficient 5 Ton Portable Air Conditioner with 60,000 BTU/h Cooling Capacity for Commercial and Industrial Spot Cooling – Koldwave K8HK60BF

The Koldwave K8HK60BF is a 60,000 BTU/h air-cooled portable air conditioner designed to provide high-capacity supplemental cooling for commercial, industrial, and temporary cooling applications. Combining a high-capacity refrigeration system, internal thermostat settings, an insulated steel cabinet, and a portable four-wheel caster design, this self-contained cooling system provides flexible temperature control where permanent HVAC installation may be impractical. Its cleanable air filters, forklift slots, and lifting lugs support maintenance and handling in demanding industrial environments, including manufacturing facilities, warehouses, equipment rooms, and other spaces requiring temporary or supplemental cooling.

Key Benefits

  • 60,000 BTU/h Cooling Capacity – Provides 5 tons of nominal cooling capacity for demanding commercial and industrial supplemental cooling applications.
  • Air-Cooled Refrigeration System – Provides cooling without requiring a dedicated condenser water supply, subject to proper condenser exhaust arrangements.
  • Internal Thermostat Settings – Supports temperature regulation according to application requirements.
  • High-Volume Airflow – Delivers a rated cool-air airflow of 1,998 CFM to distribute conditioned air throughout the intended area.
  • Heavy-Duty Four-Wheel Casters – Support movement between suitable work areas as cooling requirements change.
  • Cleanable Air Filters – Allow routine filter maintenance to help maintain airflow and cooling performance.
  • Forklift Slots and Lifting Lugs – Provide handling options for positioning and relocating the heavy-duty unit.
  • R-32 Refrigerant – Uses a refrigerant classified as A2L with a lower global warming potential than many legacy refrigerants.

High-Capacity Cooling Performance

The Koldwave K8HK60BF delivers a rated cooling capacity of 60,000 BTU/h (17.58 kW), equivalent to 5 tons of refrigeration. Its air-cooled refrigeration system uses R-32 refrigerant and incorporates two compressors. According to the manufacturer's April 2026 submittal data, the unit has a rated power consumption of 6.62 kW and a rated current of 30.2 amps. The specified ambient operating temperature range is 64°F to 113°F. The manufacturer lists a total refrigerant charge of 67 oz (1,900 g), divided equally between the two compressors. Actual cooling performance depends on ambient conditions, the room's heat load, airflow, condenser exhaust configuration, and installation conditions.

Spot Cooling and Targeted Temperature Control

The Koldwave K8HK60BF incorporates internal thermostat settings to support temperature regulation during cooling operation. Its high-capacity refrigeration system is intended for supplemental cooling in commercial and industrial environments where existing HVAC equipment may not provide sufficient cooling or where temporary temperature control is required. The unit can be considered for equipment areas, manufacturing workstations, and other spaces requiring additional cooling capacity. Verify the intended spot-cooling or room-cooling configuration, compatible supply-air ducting, and temperature-control capabilities against the applicable manufacturer's installation and operation documentation before installation.

Airflow and Distribution

The Koldwave K8HK60BF provides rated cool-air airflow of 1,998 CFM (3,395 cubic meters per hour). This airflow supports the distribution of conditioned air in demanding commercial and industrial applications. Proper air circulation helps deliver cooling to the intended space, while the condenser section must have an appropriate arrangement for rejecting heat outside the conditioned area. Verify the supply-air and condenser-air connection sizes, ducting requirements, and maximum allowable duct lengths using the manufacturer's installation documentation. Keep air intake and discharge openings unobstructed and maintain the required service clearances to support reliable operation.

Portable Design and Flexible Installation

The Koldwave K8HK60BF features a heavy-duty painted steel cabinet internally insulated with fiberglass insulation. The manufacturer's submittal lists dimensions of approximately 30 inches wide, 59 inches deep, and 58 inches high, with a net weight of 672 pounds and a gross shipping weight of 773 pounds. Four heavy-duty casters support movement within suitable facilities, while standard forklift slots and lifting lugs provide additional handling options. The portable configuration supports temporary cooling where permanent HVAC installation is impractical. Installation requires adequate clearance for airflow and maintenance, a suitable condenser exhaust arrangement, and compatible electrical service. Position the unit on a stable surface capable of supporting its operating weight, and follow the manufacturer's lifting, handling, and installation instructions.

Condensate Management

Moisture may condense on the evaporator coil during cooling operation and must be removed using the condensate management arrangement specified for the Koldwave K8HK60BF. Confirm the approved condensate drainage configuration in the manufacturer's installation and operation manual before commissioning. Ensure that the drain connection is properly routed and that drainage provisions comply with the manufacturer's requirements. Inspect the drainage components periodically for blockages, leaks, or abnormal moisture accumulation to help prevent water-related operating problems. Do not assume that an internal condensate pump or automatic condensate removal system is included unless confirmed by the documentation for the supplied configuration.

Controls, Comfort and Electrical Connection

The Koldwave K8HK60BF features internal thermostat settings for temperature control. The unit requires a 220V, single-phase, 60Hz electrical supply. Manufacturer submittal data lists a rated current of 30.2 amps and power consumption of 6.62 kW. Confirm the exact plug or hardwired connection configuration, circuit protection, disconnect requirements, grounding, and conductor sizing against the equipment nameplate and official installation documentation before installation. Provide a properly grounded electrical connection and ensure that the supply circuit meets applicable electrical codes and manufacturer requirements. Electrical installation and servicing must be performed by qualified personnel.

Commercial and Industrial Applications

The Koldwave K8HK60BF is designed for high-capacity supplemental cooling in commercial and industrial environments, including manufacturing facilities, warehouses, equipment rooms, production areas, workshops, and temporary cooling locations. Its 60,000 BTU/h cooling capacity supports substantial heat loads where existing HVAC equipment requires assistance or permanent cooling infrastructure is impractical. The air-cooled design eliminates the need for a dedicated condenser water supply, while the portable cabinet and industrial handling features support deployment in suitable facilities. Application suitability depends on the calculated cooling load, ambient temperature, ventilation, condenser exhaust arrangement, available electrical service, and installation conditions.

Mobility and Deployment

The Koldwave K8HK60BF includes four heavy-duty casters, forklift slots, and lifting lugs to support handling and deployment. With a net weight of approximately 672 pounds, the unit requires appropriate material-handling equipment, a suitable transport route, and a supporting floor surface rated for its weight. Before relocation, switch off the unit, isolate the electrical supply, and secure or disconnect ducting and condensate connections as required. After repositioning, verify that the unit is stable, air passages are unobstructed, and the required exhaust, drainage, and electrical connections are correctly restored before restarting operation.

Service and Maintenance

The Koldwave K8HK60BF incorporates cleanable air filters to support routine maintenance. Inspect and clean the filters according to the manufacturer's instructions to help maintain airflow and cooling performance. Keep air intake and discharge openings clear of dust and debris, inspect the condenser exhaust arrangement for secure connections, and periodically check the condensate drainage system. Follow the manufacturer's recommended maintenance schedule for the compressors, refrigeration circuit, and electrical components. Before cleaning or servicing the unit, switch it off and disconnect or isolate the electrical supply. Refrigeration-system repairs and electrical servicing should be performed by qualified personnel trained to work with R-32 refrigerant and equipment using A2L-classified refrigerants.

Warranty

Koldwave publishes a limited product warranty subject to the manufacturer's applicable terms, conditions, and exclusions. Confirm the applicable parts and compressor coverage periods, registration requirements, and service procedures for the K8HK60BF using the official Koldwave warranty documentation supplied with the equipment. Warranty eligibility may depend on the purchase date, installation, and other conditions specified in the manufacturer's warranty terms.

Recommended Accessories

  • Compatible Condenser Exhaust Ducting – Routes warm condenser air away from the conditioned space; verify the approved connection diameter, maximum duct length, and installation configuration.
  • Compatible Supply-Air Ducting – Supports delivery of conditioned air to designated work areas; confirm the required duct dimensions and allowable lengths using the manufacturer's documentation.
  • Condenser Exhaust Duct Adapters – Support approved condenser exhaust configurations; verify connection sizes and compatibility before ordering.
  • Condensate Drainage Hose and Fittings – Support condensate removal; confirm the required drainage configuration and connections against the manufacturer's installation instructions.
  • Replacement Cleanable Air Filters – Support routine maintenance and airflow; confirm the correct replacement components for the K8HK60BF.
  • Electrical Disconnect and Connection Components – Support compliant installation of the 220V single-phase electrical supply; select components according to the equipment nameplate, manufacturer instructions, and applicable electrical codes.

High-Capacity Portable Cooling with the Koldwave K8HK60BF

Experience flexible supplemental cooling with the Koldwave K8HK60BF portable air conditioner. Combining 60,000 BTU/h of cooling capacity with internal thermostat settings, 1,998 CFM of cool-air airflow, a heavy-duty insulated steel cabinet, cleanable filters, and industrial handling provisions, this air-cooled portable air-conditioning system provides a practical cooling solution for demanding commercial and industrial environments where temporary or supplemental temperature control is required.

No Return Policy

All Koldwave commercial unit sales are final and are non-refundable.

More Information
Koldwave 5 Ton 60,000 BTU Air-Cooled Portable Air Conditioner Industrial Horizontal | 220V - R32
FeatureSpec
SKUK8HK60BF
Weight (in lbs)672
Brand/ManufacturerKoldwave
Replaces6HK60BGA2ACA0
Cooling BTU60,000
RefrigerantR32
Electrical220v / 1 Phase / 60 Hz
PhaseSingle Phase
Tonnage5 Ton
Operating ModeCooling
Height58"
Width30"
Depth59"
Resources You will need Adobe® Acrobat® Reader to view PDF documents
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Koldwave 5 Ton 60,000 BTU Air-Cooled Portable Air Conditioner Industrial Horizontal | 220V - R32
Your Rating
Customer Questions
Does this Portable Air Conditioner require venting to outside to work correctly?
Yes, this Portable Air Conditioner requires venting to a space outside of the home/work space in order to work properly.
Did you find what you were looking for?
blockboard tech