Your cookie preferences
We use cookies to remember your preferences and understand how shoppers use our site, helping us improve your shopping experience.
Read our privacy policyThe L.B. White BOSS™ 1000 DF is a 1,000,000 BTU/h portable direct-fired forced-air heater designed to provide high-output supplemental heating for large construction sites, industrial facilities, and other suitable work environments. Combining 5,000 CFM blower output with dual-fuel compatibility for liquid propane (LP) and natural gas (NG), this heavy-duty heating system delivers high-volume heat distribution with flexible fuel options. Its built-in thermostat, onboard voltmeter, electronic spark ignition, and diagnostic indicator support convenient operation and monitoring. Featuring a Tri-Shield™ coated steel housing, no-flat wheels, a cool-end handle, and a fan-only ventilation mode, the BOSS 1000 DF provides powerful temporary heating with practical mobility and storage features for demanding job sites.
The L.B. White BOSS™ 1000 DF delivers a rated heating capacity of 1,000,000 BTU/h for supplemental heating in large construction and industrial environments. Its forced-air system provides a rated blower output of 5,000 cubic feet per minute (CFM), helping distribute heated air throughout the intended work area. The direct-fired heating process transfers combustion heat directly into the moving air, with L.B. White identifying approximately 99% fuel efficiency for the BOSS heater series. The integrated thermostat supports temperature management, while the high-volume airflow helps deliver heat across large, open spaces. Actual heating coverage depends on ambient temperature, enclosure dimensions, insulation, air infiltration, ventilation, and other site conditions.
The L.B. White BOSS™ 1000 DF uses direct-fired combustion technology and operates on either liquid propane or natural gas. Its electronic spark ignition system supports burner startup, while the integrated blower distributes heated air into the surrounding space. The manufacturer's QuickSwitch™ dual-fuel design allows operators to select the appropriate fuel configuration according to the supplied operating instructions, reducing the need for major equipment changes when switching between approved fuel sources. Direct-fired heating transfers combustion heat directly into the airstream without a separate heat exchanger. Because combustion products enter the heated air, adequate ventilation and compliance with the manufacturer's application requirements are essential. Use the heater only in permitted applications and never operate it in unventilated spaces or human living quarters.
The L.B. White BOSS™ 1000 DF provides a rated blower output of 5,000 CFM to distribute high volumes of heated air throughout large work areas. Its integrated fan supports temporary heating in construction sites, industrial facilities, and other suitable environments requiring substantial heat delivery. The heater also includes a fan-only ventilation mode, allowing air to circulate without activating the burner when ventilation is appropriate for the application. The manufacturer identifies this model as non-ductable. Do not attach ductwork or restrict the air intake or discharge. Maintain the manufacturer's specified clearances and provide sufficient ventilation to support safe combustion and acceptable air quality.
The L.B. White BOSS™ 1000 DF features a rugged portable design intended for demanding temporary-heating applications. Manufacturer-published dimensions are approximately 60.13 inches long, 30.75 inches wide, and 32.32 inches high. The listed unit weight is approximately 350 lb, with a shipping weight of approximately 440 lb. No-flat wheels and a cool-end handle support transportation and positioning, while the housing can stand on end and stack for storage when handled in accordance with manufacturer instructions. The unit is designed to fit through a standard 36-inch door frame when moved in the appropriate configuration. The heater requires a compatible LP or natural gas supply and a 120 V electrical connection. Position the unit securely, maintain the specified clearances, and follow the owner's manual for fuel connections, electrical supply, ventilation, and operation.
The L.B. White BOSS™ 1000 DF operates on liquid propane or natural gas, with fuel consumption varying by fuel type. Manufacturer specifications list LP gas consumption at approximately 46.3 lb/h and natural gas consumption at approximately 1,000 cubic feet per hour. The specified inlet gas pressure range is 7 to 13.5 inches water column for both LP and natural gas. Verify the gas supply capacity, regulator configuration, inlet pressure, and connection requirements against the current owner's manual before installation. The heater requires a 120 V, 60 Hz, single-phase electrical supply, with a listed starting current of 23.2 A and continuous operating current of 8.4 A. Its motor is rated at 1 horsepower. Provide an appropriately rated electrical circuit and confirm the unit nameplate and installation requirements before use.
The L.B. White BOSS™ 1000 DF includes a built-in thermostat, an onboard voltmeter, an electronic spark ignition system, and a diagnostic indicator. The thermostat supports temperature management by controlling heating operation according to the selected setting, while the voltmeter helps operators monitor the electrical supply. The fan-only ventilation mode allows the blower to circulate air without activating the burner. Electrical requirements are 120 V, 60 Hz, single-phase power, with a listed starting current of 23.2 A and continuous operating current of 8.4 A. Because startup current exceeds continuous operating current, verify circuit capacity, overcurrent protection, grounding, and extension-cord requirements against the current owner's manual and unit nameplate. Electrical connections must comply with the manufacturer's instructions and applicable codes.
The L.B. White BOSS™ 1000 DF is designed for high-output supplemental heating in large construction sites, industrial facilities, and other suitable work environments. Its 1,000,000 BTU/h heating capacity and 5,000 CFM blower output make it suitable for applications requiring substantial temporary heat distribution. Dual-fuel compatibility allows the heater to operate on LP or natural gas, providing flexibility where either approved fuel supply is available. Its portable construction supports deployment as site requirements change, while the thermostat and fan-only ventilation mode offer practical operating flexibility. The BOSS 1000 DF is intended for use in self-ventilated areas. Confirm application suitability, ventilation provisions, and local safety requirements before operation.
The L.B. White BOSS™ 1000 DF measures approximately 60.13 inches long, 30.75 inches wide, and 32.32 inches high, with a listed unit weight of approximately 350 lb. Its no-flat wheels and cool-end handle support transportation and positioning between suitable work areas. The housing can stand on end and stack for storage when handled according to the manufacturer's instructions. Because of the heater's weight, use appropriate handling equipment and procedures when loading, unloading, and relocating the unit. Position the heater securely on a stable surface, maintain the required clearances, and route gas hoses and electrical connections to minimize damage and tripping hazards. Shut off the fuel supply, disconnect electrical power as directed, and allow the unit to cool before moving or servicing it.
The L.B. White BOSS™ 1000 DF incorporates electronic spark ignition, thermostat control, an onboard voltmeter, a diagnostic indicator, and a fan-only ventilation mode. Its Tri-Shield™ coated steel housing and powder-coated hardware are designed to resist abrasion and corrosion in demanding work environments. Manufacturer documentation lists the BOSS 1000 DF as certified to ANSI Z83.7-2017 and CSA 2.14-2017 for the United States and Canada. Inspect the heater, gas supply connections, regulator, hoses, electrical components, wheels, housing, and air openings before operation. Check gas connections for leaks using an approved procedure, maintain adequate ventilation and specified clearances, and keep the air intake and discharge unobstructed. Direct-fired combustion can produce carbon monoxide, carbon dioxide, and nitrogen dioxide, so adequate air exchange is essential. Never operate the heater in unventilated spaces or human living quarters. Disconnect power and shut off the gas supply as directed before cleaning or servicing. Follow the current owner's manual for inspection, troubleshooting, and maintenance, and have gas-system and electrical repairs performed by appropriately qualified personnel. Never bypass safety devices.
The L.B. White BOSS™ 1000 DF includes a manufacturer-published two-year limited warranty. Refer to the applicable written L.B. White warranty for coverage details, exclusions, registration requirements, and installation, operation, and maintenance conditions. Warranty eligibility may depend on compliance with the manufacturer's instructions and use of approved fuel-system components. Confirm the current warranty terms with L.B. White or an authorized dealer before purchase.
Experience powerful supplemental heating with the L.B. White BOSS™ 1000 DF Portable Direct-Fired Heater. Combining 1,000,000 BTU/h heating capacity with 5,000 CFM blower output, LP and natural gas compatibility, electronic spark ignition, a built-in thermostat, and an onboard voltmeter, this heavy-duty heater provides high-volume heat distribution for suitable construction and industrial applications. Its no-flat wheels, cool-end handle, fan-only ventilation mode, diagnostic indicator, and durable Tri-Shield™ coated steel housing support convenient operation, transportation, and storage wherever direct-fired gas heating is appropriate and the required fuel supply, electrical connection, ventilation, and safety clearances are available.
Hose and regulator sold separately.