LB White 230,000 BTU LINK Capable Diesel Indirect-Fired Portable Heater | 120V

SAVE $6,720.00
By

LB White

In stock
Model

Foreman 230 Oil LINK Capable

ID

153820

Was $11,890.00 Your Low Price Special Price $5,170.00
Ships in 2-3 Weeks
Free Shipping
 

Indirect-Fired Clean, Dry Heat 230,000 BTU Portable Oil Heater for Construction & Industrial Applications

The L.B. White FOREMAN® 230 Oil 2.0 LINK™ Capable is a 230,000 BTU/h portable indirect-fired oil heater designed to deliver clean, dry heated air for construction sites, industrial facilities, warehouses, loading docks, and suitable temporary enclosures. Operating on #1 or #2 diesel fuel, this self-contained heating system combines a Beckett® burner, a fully welded heat exchanger, and 1,900 CFM blower output to distribute heat while keeping combustion exhaust separate from the heated air supplied to the workspace. Its onboard 42-gallon fuel tank, ductable air outlet, remote thermostat compatibility, and portable wheeled design support flexible deployment where dependable temporary heat is required. The LINK™ Capable configuration can be upgraded for connection to L.B. White's LINK™ equipment monitoring platform using the appropriate additional hardware, helping equipment managers improve fleet visibility, monitor runtime, and plan maintenance.

Key Benefits

  • 230,000 BTU/h Heating Capacity – Provides high-output supplemental heat for suitable construction, industrial, and temporary enclosure applications.
  • Indirect-Fired Heating Technology – Uses a fully welded heat exchanger to separate combustion gases from the heated air delivered into the workspace.
  • #1 and #2 Diesel Compatibility – Supports operation with either manufacturer-approved diesel fuel type.
  • 1,900 CFM Blower Output – Circulates heated air through compatible ducting to distribute warmth throughout the intended area.
  • 42-Gallon Onboard Fuel Tank – Provides integrated fuel storage for portable operation without requiring a separate tank for standard operation.
  • Ductable Heat Distribution – Supports flexible placement and delivery of heated air through compatible ductwork.
  • Beckett® Oil Burner – Provides a dedicated oil-fired combustion system for high-output heating performance.
  • Remote Thermostat Compatibility – Supports compatible remote temperature control for convenient heating management.
  • LINK™ Capable Connectivity – Can be upgraded with the required LINK™ hardware to support remote equipment monitoring and maintenance planning.
  • Portable Construction – Includes wheels, a handle, and a single-point lifting bail to facilitate transportation and positioning.
  • Two-Year Manufacturer Warranty – The FOREMAN® 230 Oil model is listed with a two-year warranty, subject to the applicable written warranty terms.

230,000 BTU/h High-Output Heating Performance

The L.B. White FOREMAN® 230 Oil 2.0 delivers a rated heating input of 230,000 BTU/h for temporary heating in construction, industrial, and other suitable applications. Its forced-air system provides a rated blower output of 1,900 cubic feet per minute (CFM), helping distribute heat through compatible outlet ducting. The fully welded heat exchanger transfers heat from the combustion process to the heated-air stream while keeping combustion exhaust separate from the air supplied to the workspace. This configuration is particularly useful when applications require clean, dry heated air without direct exposure to burner exhaust. Actual heating coverage depends on ambient temperature, enclosure dimensions, insulation, air infiltration, duct configuration, and other site conditions.

Indirect-Fired Diesel Heating Technology

The L.B. White FOREMAN® 230 Oil 2.0 uses an oil-fired Beckett® burner and indirect-fired heating technology. The burner heats a fully welded heat exchanger, and the integrated fan moves air across the exchanger to deliver heated air into the intended space. Combustion gases are routed through a separate exhaust system rather than mixed with the heated supply air. The heater operates on #1 or #2 diesel fuel, providing fuel flexibility for construction and industrial sites. Proper installation of the exhaust pipe and rain cap is essential to discharge combustion byproducts safely. Follow L.B. White's installation instructions for exhaust routing, fuel connections, ventilation, clearances, and operating procedures.

1,900 CFM Airflow & Ducted Heat Distribution

The L.B. White FOREMAN® 230 Oil 2.0 provides a rated blower output of 1,900 CFM for distribution of heated air throughout the intended work area. Its ductable design supports flexible placement of the heater while allowing heated air to be directed to designated locations through compatible ductwork. Manufacturer specifications list a 12-inch outlet duct connection and support duct lengths up to 100 feet, subject to the approved configuration and installation requirements. A 16-inch duct adapter is available separately for compatible duct arrangements. Use manufacturer-approved ducting, adapters, and retaining accessories, and follow the specified duct length, clearance, and airflow requirements. Keep air intake and discharge openings unobstructed to support effective heat distribution and reliable operation.

Portable Design & Flexible Installation

The L.B. White FOREMAN® 230 Oil 2.0 features a portable, self-contained design for temporary heating applications. Manufacturer-published dimensions are approximately 60.2 inches long, 26.6 inches wide, and 43.3 inches high. The listed unit weight is approximately 363 lb, with a shipping weight of approximately 460 lb. Integrated wheels, a handle, and a single-point lifting bail support transportation and placement at suitable work sites. The FOREMAN 230 Oil 2.0 can be stored on end when permitted by the manufacturer's handling and storage instructions. The heater requires an appropriate diesel fuel supply, a suitable electrical connection, compatible heated-air ducting, and a properly installed exhaust system. Position the heater securely, maintain all required clearances, and follow the current owner's manual for installation and operation.

Fuel Management & Operating Duration

The L.B. White FOREMAN® 230 Oil 2.0 operates on #1 or #2 diesel fuel and has a maximum listed fuel consumption of approximately 1.7 gallons per hour. Its onboard fuel tank has a published capacity of 42 gallons, providing integrated fuel storage for temporary operation. Actual runtime varies according to fuel consumption, operating conditions, and control settings. The onboard tank helps simplify deployment where a separate external tank is unnecessary for standard operation. For applications requiring a remote fuel supply, L.B. White lists a separate remote oil hookup kit for the FOREMAN 230 and 500 models. Use only manufacturer-approved fuels and components, and follow the owner's manual for filling, fuel filtration, burner maintenance, and storage.

Controls, Temperature Management & Electrical Connection

The L.B. White FOREMAN® 230 Oil 2.0 uses burner and fan controls to manage the heating process and supports compatible remote thermostat operation. A suitable remote thermostat helps regulate heating according to the desired ambient temperature, reducing the need for continuous manual adjustment. The heater requires a 120 V, 60 Hz, single-phase electrical supply. Manufacturer-published specifications list a 1/2-horsepower motor and a starting current of approximately 32 A, with a continuous current draw of approximately 9 A. The heater must be connected to a properly wired and grounded electrical supply, and the manufacturer specifies a minimum 15 A breaker for the 230 Oil model. Confirm startup requirements, circuit capacity, grounding, connection configuration, and overcurrent protection against the current unit nameplate and owner's manual before installation. Electrical connections must comply with the manufacturer's instructions and applicable codes.

Construction, Warehouse & Industrial Applications

The L.B. White FOREMAN® 230 Oil 2.0 is designed for supplemental heating in construction sites, warehouses, industrial facilities, loading docks, and suitable temporary enclosures requiring indirect-fired heat. Its 230,000 BTU/h heating capacity, 1,900 CFM blower output, and separate combustion exhaust system make it suitable for applications where heated supply air must remain separate from combustion gases. The ductable configuration supports flexible positioning and delivery of heat to designated areas. The indirect-fired design is suitable for approved enclosed applications when the heater is installed and operated according to manufacturer instructions, including proper exhaust routing and combustion-air provisions. Always verify suitability for the specific occupancy and work environment, and follow applicable safety requirements.

LINK™ Capable Equipment Monitoring & Fleet Management

The L.B. White FOREMAN® 230 Oil 2.0 LINK™ Capable is compatible with the L.B. White LINK™ equipment monitoring platform but requires additional compatible hardware to establish the streamlined connection available with LINK™ Ready models. The manufacturer's parts documentation identifies a LINK Capable conversion kit for compatible FOREMAN oil models. When the required LINK™ hardware is installed and the service is activated, connected monitoring can provide access to equipment information such as location, runtime, operating status, and maintenance-related alerts, depending on the installed configuration. These capabilities can help equipment managers track utilization, coordinate preventive maintenance, and improve fleet visibility across multiple job sites. The LINK™ Capable designation does not mean that the required telematics module or subscription is included. Confirm the correct upgrade kit, installation requirements, and current service terms with L.B. White or an authorized dealer.

Mobility & Deployment

The L.B. White FOREMAN® 230 Oil 2.0 measures approximately 60.2 inches long, 26.6 inches wide, and 43.3 inches high. Its wheels, handle, and single-point lifting bail support relocation between suitable temporary-heating locations. With a listed unit weight of approximately 363 lb, appropriate lifting equipment and handling procedures are necessary for loading, unloading, and transport. Position the heater on a stable surface, secure it against unintended movement, and maintain the manufacturer's specified clearances. Route ducting, the exhaust pipe, and electrical connections to avoid damage and trip hazards. Shut down the burner, disconnect electrical power as directed, and allow the equipment to cool before moving or servicing it.

Safety, Service & Maintenance

The L.B. White FOREMAN® 230 Oil 2.0 incorporates an oil-fired Beckett® burner, a fully welded heat exchanger, and a separate combustion exhaust system. Its indirect-fired design helps keep combustion gases separate from the heated supply air. L.B. White's published documentation identifies the FOREMAN 230 Oil as certified to applicable ANSI/CSA standards for the United States and Canada. Inspect the fuel tank, fuel lines, burner, electrical connections, fan, heat exchanger, ducting, and exhaust components before operation. Ensure the exhaust system is installed according to manufacturer instructions, including the specified pipe configuration and rain cap. Maintain clear airflow, check the fuel system for leaks, and remove accumulated dust or debris as directed. Shut off the heater, disconnect electrical power, and allow hot components to cool before servicing. Follow the current owner's manual for fuel-filter, nozzle, burner, and heat-exchanger maintenance. Repairs to the burner, fuel system, electrical components, and exhaust installation should be performed by appropriately qualified personnel.

Warranty

The L.B. White FOREMAN® 230 Oil 2.0 is listed with a two-year manufacturer warranty. Refer to the applicable written L.B. White warranty for coverage details, exclusions, registration requirements, and installation, operation, and maintenance conditions. Warranty eligibility may depend on compliance with the manufacturer's instructions and use of approved fuel and replacement components. Confirm the current warranty terms with L.B. White or an authorized dealer before purchase.

Recommended Accessories

  • LINK™ Capable Conversion Kit – Manufacturer parts documentation lists kit Part No. 500-133193 for FOREMAN 230 Oil, 500/750 DF, and 500/750 Oil models. Verify the current kit specification and compatibility with the exact heater configuration before ordering.
  • LINK™ Module Kit – Manufacturer Part No. 500-133225. Required compatible hardware for connecting eligible LINK Capable equipment to the monitoring platform. Confirm the appropriate kit and service requirements with L.B. White.
  • Remote Thermostat, NEMA 4X, with 25-Foot Cord – Manufacturer accessory Part No. 30125. Supports remote temperature control when configured according to L.B. White instructions.
  • 12-Inch Fire-Retardant Duct, 25-Foot – Manufacturer accessory Part No. 30052, supplied with a clamp. Verify the required outlet configuration and compatibility with the FOREMAN 230 Oil 2.0.
  • 20-Inch Recirculating Duct, 25-Foot – Manufacturer accessory Part No. 30053, supplied with a clamp. Confirm the intended recirculation arrangement and installation requirements before ordering.
  • 16-Inch Fire-Retardant Duct, 25-Foot – Manufacturer accessory Part No. 30076, supplied with a clamp. Verify compatibility with the selected duct adapter configuration.
  • 16-Inch Duct Adapter Kit – Manufacturer accessory Part No. 30902. Confirm compatibility with the FOREMAN 230 Oil 2.0 and the intended duct arrangement.
  • Remote Oil Hookup Kit – Manufacturer Part No. 500-131261, listed for connecting compatible FOREMAN 230 and 500 models to a remote fuel tank. Verify the installation requirements and compatibility before ordering.
  • Exhaust Pipe and Rain Cap – Select the manufacturer-approved exhaust components compatible with the FOREMAN 230 Oil 2.0 to discharge combustion byproducts and help prevent water entry. Verify the correct pipe dimensions and part numbers through official L.B. White documentation.

Clean, Dry Heating Performance with the L.B. White FOREMAN® 230 Oil 2.0 LINK™ Capable

Experience high-output indirect-fired heating with the L.B. White FOREMAN® 230 Oil 2.0 LINK™ Capable Portable Heater. Combining 230,000 BTU/h heating capacity with 1,900 CFM blower output, a Beckett® oil burner, a fully welded heat exchanger, and an onboard 42-gallon fuel tank, this portable heating system delivers clean, dry heated air for suitable construction, warehouse, and industrial applications. Its ductable design, wheeled frame, single-point lifting bail, and upgrade path to LINK™ equipment monitoring support flexible deployment and fleet management wherever temporary indirect-fired heating is required.

More Information
LB White 230,000 BTU LINK Capable Diesel Indirect-Fired Portable Heater | 120V
FeatureSpec
SKUForeman 230 Oil LINK Capable
Weight (in lbs)354
Brand/ManufacturerLB White
Heating BTU230,000
Maximum CFM1,900
Horsepower1/2 Motor Horsepower
Capacity43 Gallon Tank Capacity
Electrical120 Volts | 60 Hz | 1 Phase
Operating ModeHeating
Fuel TypeDiesel
ColorWhite
Length60.2"
Height43.3″
Width26.6″
Warranty2-year warranty and lifetime of technical support.
Resources You will need Adobe Acrobat Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:LB White 230,000 BTU LINK Capable Diesel Indirect-Fired Portable Heater | 120V
Your Rating
Customer Questions
What is a Portable Heater, and how does it work?
A portable heater is a movable heating unit that provides supplemental or targeted warmth without permanent installation. Depending on the type, it generates heat using electricity, propane, natural gas, or kerosene and distributes it through radiant or forced-air heating.Portable heaters are commonly used in warehouses, workshops, construction sites, garages, and other commercial or residential spaces.
What types of Portable Heaters are available, and which Fuel Type is the best for your heating needs?
Portable heaters are available in electric, propane, natural gas, and kerosene models, each suited to different applications. The best fuel type depends on the heating capacity needed, the available power or fuel supply, ventilation, and whether the space is occupied.Electric: ideal for indoor spaces with adequate electrical capacity.Propane, natural gas, and kerosene: high heat output for construction sites, warehouses, and industrial environments.
What is the difference between direct-fired and indirect-fired Portable Heaters?
Direct-fired portable heaters release heat and combustion byproducts directly into the heated space, so they are best suited to well-ventilated areas. Indirect-fired heaters use a heat exchanger to deliver clean heated air while exhausting combustion gases outside.Indirect-fired models are ideal for enclosed or occupied spaces where cleaner heated air is needed.
What is the difference between radiant and forced-air Portable Heaters?
Radiant portable heaters warm people and objects directly, making them ideal for targeted heating in work areas. Forced-air portable heaters use a fan to circulate warm air throughout a space, making them better suited to larger areas such as warehouses, workshops, and construction sites.The best option depends on whether localized warmth or broader air circulation is needed.
Can Portable Heaters be used both indoors and outdoors?
Yes, portable heaters are available for both indoor and outdoor use, but the appropriate type depends on the fuel source, ventilation, and application.Indoors: electric and approved indirect-fired heaters are commonly used.Outdoors or well-ventilated areas: many direct-fired models are better suited.Always follow the manufacturer's safety and ventilation requirements.
Do Portable Heaters require ventilation?
Ventilation requirements for portable heaters depend on the fuel type and heating design. Direct-fired heaters require adequate ventilation because they release combustion byproducts into the heated space, while indirect-fired models exhaust those gases outdoors.Electric heaters do not produce combustion gases and generally do not require combustion ventilation.
How long will Portable Heaters run on a full fuel tank?
Runtime on a full tank depends on tank capacity, fuel type, heat output, and fuel consumption rate. Larger tanks generally provide longer operation, while higher BTU settings use fuel more quickly.As a rough estimate, runtime in hours = tank size in gallons × fuel BTU per gallon ÷ heater BTU per hour. Propane contains about 91,500 BTU per gallon and kerosene about 135,000. Check the manufacturer's specifications for actual runtime at different heat settings.
What safety features should I look for when purchasing a Portable Heater?
Look for overheat protection, automatic shutoff, flame failure protection, and tip-over protection where applicable. Fuel-fired models should also have safety controls that prevent fuel leaks or unsafe operation, along with clear ventilation requirements.Choose a heater designed for the intended environment and follow the manufacturer's safety guidelines.
How often should Portable Heaters be cleaned and maintained?
Inspect a portable heater before each use and clean it regularly to remove dust, debris, and buildup that can affect performance. Check the fuel lines, filters, burners, electrical connections, and safety controls according to the manufacturer's maintenance schedule.Regular maintenance ensures safe operation, reliable heating, and longer equipment life.
What is the difference between a Portable Heater and a temporary heating system?
A portable heater is a self-contained unit that provides targeted or supplemental heat, while a temporary heating system typically refers to larger equipment used to heat entire buildings or job sites.Portable heaters: ideal for individual work areas, workshops, and smaller spaces.Temporary heating systems: better suited to large construction projects, warehouses, and industrial facilities that need broader coverage.
Did you find what you were looking for?
blockboard tech