LB White 230,000 BTU LINK Capable Dual Fuel Indirect-Fired Portable Heater | 120V

SAVE $2,196.50
By

LB White

In stock
Model

Foreman 230 DF LINK Capable

ID

153817

Was $7,496.50 Your Low Price Special Price $5,300.00
Ships in 2-3 Weeks
Free Shipping
 

Dual-Fuel Indirect-Fired Heating with LINK™ Monitoring Capability 230,000 BTU Portable Heater for Construction & Industrial Applications

The L.B. White FOREMAN® 230 DF 2.0 LINK™ Capable is a 230,000 BTU/h portable indirect-fired heater designed to deliver clean, dry heated air for construction sites, industrial facilities, warehouses, loading docks, and suitable temporary enclosures. Operating on liquid propane (LP) or natural gas (NG), this self-contained heating system combines a Beckett® burner, a fully welded heat exchanger, and 1,900 CFM blower output to distribute heat while keeping combustion exhaust separate from the heated air supplied to the workspace. Its dual-fuel design, ductable configuration, remote thermostat compatibility, and portable wheeled frame provide flexibility for demanding temporary-heating applications. The LINK™ Capable configuration can be connected to L.B. White's LINK™ equipment monitoring platform by installing the appropriate additional hardware and harness components, helping equipment managers monitor runtime, location, operating status, and maintenance alerts.

Key Benefits

  • 230,000 BTU/h Heating Capacity – Provides high-output supplemental heat for suitable construction, industrial, and temporary enclosure applications.
  • Dual-Fuel LP and Natural Gas Operation – Supports two fuel types, providing flexibility for different job-site gas supplies.
  • Indirect-Fired Heating Technology – Uses a fully welded heat exchanger to keep combustion gases separate from the heated air delivered into the workspace.
  • 1,900 CFM Blower Output – Circulates air through the heater to distribute warmth through compatible ducting.
  • Ductable Heat Distribution – Supports flexible heater placement and delivery of heated air through approved duct configurations up to 100 feet.
  • Remote Thermostat Compatibility – Supports optional remote temperature control for convenient heating management.
  • LINK™ Capable Connectivity – Allows an upgrade with compatible LINK™ hardware for remote equipment monitoring and fleet management.
  • Portable Construction – Features wheels, a balanced handle, and a single-point lifting bail to facilitate transportation and positioning.
  • Durable Industrial Design – Combines a fully welded heat exchanger with a powder-coated protective frame for demanding work environments.
  • Two-Year Manufacturer Warranty – Supported by the manufacturer's published two-year warranty, subject to the applicable written warranty terms.

230,000 BTU/h High-Output Heating Performance

The L.B. White FOREMAN® 230 DF 2.0 delivers a rated heating input of 230,000 BTU/h for temporary heating in construction, industrial, and other suitable applications. Its forced-air system provides a rated blower output of 1,900 cubic feet per minute (CFM), helping distribute heat through compatible outlet ducting. The fully welded heat exchanger transfers energy from the combustion process to the heated-air stream while routing combustion gases through a separate exhaust system. This indirect-fired configuration is beneficial when applications require clean, dry heated supply air without direct mixing of combustion exhaust into the workspace. Actual heating coverage depends on ambient temperature, enclosure dimensions, insulation, air infiltration, duct configuration, and other site conditions.

Dual-Fuel Indirect-Fired Heating Technology

The L.B. White FOREMAN® 230 DF 2.0 uses a Beckett® burner and indirect-fired heating technology, operating on either liquid propane or natural gas. The burner heats the fully welded heat exchanger, while an integrated fan circulates air across the exchanger to deliver heated air into the intended space. Combustion gases are routed through a separate exhaust system instead of being mixed directly with the heated supply air. The dual-fuel design provides flexibility for sites with different approved fuel supplies. Manufacturer-published maximum fuel consumption is approximately 10.6 lb/h for LP and 230 cubic feet per hour for natural gas. The published inlet gas pressure range is 7 to 13.5 inches water column for both fuel types. Correct fuel selection, gas pressure, combustion-air provisions, and exhaust installation are essential for safe operation. Follow the current L.B. White owner's manual and applicable fuel-gas codes.

1,900 CFM Airflow & Ducted Heat Distribution

The L.B. White FOREMAN® 230 DF 2.0 provides a rated blower output of 1,900 CFM for distributing heated air throughout the intended work area. Its ductable configuration allows the heater to be positioned away from the area receiving heat, providing flexibility for construction sites, warehouses, industrial work areas, and suitable temporary enclosures. Manufacturer specifications list a 12-inch outlet duct connection with an approved maximum duct length of 100 feet. A 16-inch duct adapter is available separately for compatible alternative configurations. The model also supports a 16-inch air-recirculation inlet arrangement when configured with approved accessories. Use manufacturer-approved ducting and adapters, maintain adequate airflow, and follow the specified duct length and installation requirements. Keep intake and discharge openings unobstructed during operation.

Portable Design & Flexible Installation

The L.B. White FOREMAN® 230 DF 2.0 features a portable, self-contained design intended for temporary heating applications. Manufacturer-published dimensions are approximately 61 inches long, 33.5 inches wide, and 44.75 inches high. The listed unit weight is approximately 326 lb, with a shipping weight of approximately 440 lb. Its wheels, balanced handle, and single-point lifting bail support transportation and positioning at suitable work sites. The FOREMAN 230 can be stored on end when permitted by the manufacturer's handling and storage instructions. The heater requires a compatible LP or natural gas supply, an appropriate electrical connection, compatible heated-air ducting, and a correctly installed exhaust system. Position the unit securely, maintain the required clearances, and follow the current owner's manual for fuel connections, duct installation, exhaust routing, and operation.

Dual-Fuel Management & Energy Consumption

The L.B. White FOREMAN® 230 DF 2.0 operates on liquid propane or natural gas, with consumption varying according to the selected fuel. Manufacturer specifications list maximum LP consumption of approximately 10.6 lb/h and maximum natural gas consumption of approximately 230 cubic feet per hour. The published minimum and maximum inlet gas pressure range is 7 to 13.5 inches water column for both fuel types. The unit includes a gas selector valve for selecting the appropriate approved fuel configuration. Verify the gas supply capacity, regulator, hose, inlet pressure, and connection requirements against the current owner's manual before installation. The heater requires a 120 V, 60 Hz, single-phase electrical supply, with a published starting current of 32 A and continuous operating current of 9 A. Confirm electrical circuit capacity, grounding, overcurrent protection, and connection requirements against the unit nameplate and applicable codes.

Controls, Temperature Management & Electrical Connection

The L.B. White FOREMAN® 230 DF 2.0 supports optional remote thermostat control to help regulate heating according to the desired ambient temperature. The FOREMAN 2.0 series also features operator-oriented controls and diagnostic functions, depending on the model configuration. An optional weather-resistant NEMA 4X thermostat with a 25-foot cord is available for compatible installations. The heater requires a 120 V, 60 Hz, single-phase electrical supply. Manufacturer-published specifications list a 32 A starting current and a 9 A continuous current draw. Because startup current is higher than continuous operating current, verify circuit capacity, breaker requirements, grounding, and connection configuration against the current owner's manual and unit nameplate before installation. Electrical connections must comply with the manufacturer's instructions and applicable electrical codes.

Construction, Warehouse & Industrial Applications

The L.B. White FOREMAN® 230 DF 2.0 is designed for supplemental heating in construction sites, warehouses, industrial facilities, loading docks, and suitable temporary enclosures requiring indirect-fired heat. Its 230,000 BTU/h heating capacity, dual-fuel operation, and ductable configuration provide flexibility for applications where heated supply air must remain separate from combustion exhaust. The indirect-fired design supports use in appropriate enclosed work areas when the heater is installed and operated according to manufacturer instructions. Correct exhaust routing, combustion-air supply, fuel connections, and installation clearances remain essential. Confirm suitability for the specific occupancy and work environment, and follow applicable safety requirements before operation.

LINK™ Capable Equipment Monitoring & Fleet Management

The L.B. White FOREMAN® 230 DF 2.0 LINK™ Capable supports connection to the L.B. White LINK™ equipment monitoring platform through a compatible conversion kit and telematics module. Unlike LINK™ Ready models, LINK™ Capable heaters require additional wiring and harness components to establish the connection. L.B. White identifies conversion kit Part No. 500-133224 for the FOREMAN 230 DF 2.0 LINK™ Capable model. Once the compatible hardware is installed and the required service is activated, the LINK™ platform can provide equipment information such as GPS location, runtime, operating status, call-for-heat status, fuel-flow status, and telematics voltage. Users can configure critical alerts and maintenance notifications through the web-based dashboard. The platform is accessible from internet-connected computers, tablets, and mobile devices. Verify the required hardware, installation procedure, connectivity, and subscription terms with L.B. White or an authorized dealer before purchase.

Mobility & Deployment

The L.B. White FOREMAN® 230 DF 2.0 measures approximately 61 inches long, 33.5 inches wide, and 44.75 inches high. Its wheels, balanced handle, and single-point lifting bail support relocation between suitable temporary-heating locations. With a listed unit weight of approximately 326 lb, appropriate lifting equipment and handling procedures are necessary for loading, unloading, and transport. Position the heater on a stable surface, secure it against unintended movement, and maintain the manufacturer's specified clearances. Route ducting, exhaust components, gas hoses, and electrical connections to avoid damage and trip hazards. Shut off the fuel supply, disconnect electrical power as directed, and allow the heater to cool before moving, cleaning, or servicing it.

Safety, Service & Maintenance

The L.B. White FOREMAN® 230 DF 2.0 incorporates an indirect-fired burner system, a fully welded heat exchanger, and a separate combustion exhaust system. Its design helps keep combustion gases separate from the heated supply air. L.B. White's published specifications identify the FOREMAN 230 DF 2.0 as certified to applicable ANSI/CSA standards for the United States and Canada. Inspect the burner, gas hoses, regulators, fuel connections, electrical components, fan, heat exchanger, ducting, and exhaust components before operation. Check gas connections for leaks using an approved procedure and verify that the exhaust system is installed according to manufacturer instructions, including the required pipe configuration and rain cap. Maintain unobstructed airflow and specified clearances, and remove accumulated dust or debris as directed by the manufacturer. Indirect-fired operation does not eliminate the need to discharge combustion exhaust safely outdoors. Shut off the heater, disconnect electrical power, and allow hot components to cool before servicing. Follow the current owner's manual for inspection, cleaning, burner maintenance, and troubleshooting. Gas-system and electrical repairs must be performed by appropriately qualified personnel. Never bypass safety devices or operate the heater with damaged components.

Warranty

The L.B. White FOREMAN® 230 DF 2.0 is covered by the manufacturer's published two-year warranty, subject to the applicable written warranty terms. Refer to L.B. White's current warranty documentation for coverage details, exclusions, registration requirements, and installation, operation, and maintenance conditions. Warranty eligibility may depend on compliance with the manufacturer's instructions and use of approved fuel-system components. Confirm the current warranty terms with L.B. White or an authorized dealer before purchase.

Recommended Accessories

  • LINK™ Capable Conversion Kit – Manufacturer Part No. 500-133224, identified for the FOREMAN 230 DF 2.0 LINK™ Capable model. Includes the required model-specific wiring and harness components for connection to compatible LINK™ hardware. Verify the current kit specification before ordering.
  • LINK™ Telematics Module Kit – Manufacturer Part No. 500-133225. Provides the compatible monitoring module for eligible LINK™ configurations. Confirm the required subscription and activation terms with L.B. White.
  • Remote Thermostat, NEMA 4X, with 25-Foot Cord – Manufacturer accessory Part No. 30125. Supports remote temperature control when configured according to L.B. White instructions.
  • 12-Inch Fire-Retardant Duct, 25-Foot – Manufacturer accessory Part No. 30052, supplied with a clamp. Verify compatibility with the specified outlet configuration.
  • 20-Inch Recirculating Duct, 25-Foot – Manufacturer accessory Part No. 30053, supplied with a clamp. Confirm the intended recirculation arrangement and installation requirements before ordering.
  • 16-Inch Fire-Retardant Duct, 25-Foot – Manufacturer accessory Part No. 30076, supplied with a clamp. Verify compatibility with the approved duct adapter configuration.
  • 16-Inch Duct Adapter Kit – Manufacturer accessory Part No. 30902. Confirm compatibility with the FOREMAN 230 DF 2.0 and the intended duct arrangement.
  • 3/4-Inch-by-15-Foot Gas Hose – Manufacturer accessory Part No. 25965, listed for compatible FOREMAN 230/500 dual-fuel models. Verify fuel type, pressure, and connection compatibility before ordering.
  • Dual-Fuel Gas Regulator – Manufacturer accessory Part No. 25141, listed for FOREMAN DF models. Verify the required configuration, particularly for natural gas installations, against the manufacturer's instructions.
  • 6-Inch Steel Exhaust Pipe Extension – Manufacturer accessory Part No. 30161, listed for FOREMAN 230, 500, and 750 DF models. Verify the required exhaust configuration before ordering.
  • Rain Cap – Manufacturer accessory Part No. 30162, listed for FOREMAN 230, 500, and 750 DF models. Use with the approved exhaust arrangement to help prevent water entry.

Clean, Dry Portable Heat with the L.B. White FOREMAN® 230 DF 2.0 LINK™ Capable

Experience high-output indirect-fired heating with the L.B. White FOREMAN® 230 DF 2.0 LINK™ Capable Portable Heater. Combining 230,000 BTU/h heating capacity with LP and natural gas compatibility, a Beckett® burner, a fully welded heat exchanger, and 1,900 CFM blower output, this portable heating system delivers clean, dry heated air for suitable construction, warehouse, and industrial applications. Its ductable design, wheeled frame, single-point lifting bail, and upgrade path to LINK™ equipment monitoring support flexible deployment and fleet management wherever temporary indirect-fired heating is required.

More Information
LB White 230,000 BTU LINK Capable Dual Fuel Indirect-Fired Portable Heater | 120V
FeatureSpec
SKUForeman 230 DF LINK Capable
Weight (in lbs)307
Brand/ManufacturerLB White
Heating BTU230,000
Maximum CFM1,900
Horsepower1/2 Motor Horsepower
Electrical120 Volts | 60 Hz | 1 Phase
Operating ModeHeating
Fuel TypePropane, Natural Gas, Multi-Fuel
ColorWhite
Length60.2"
Height43.3″
Width26.6″
Warranty2-year warranty and lifetime of technical support.
Resources You will need Adobe Acrobat Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:LB White 230,000 BTU LINK Capable Dual Fuel Indirect-Fired Portable Heater | 120V
Your Rating
Customer Questions
What is a Portable Heater, and how does it work?
A portable heater is a movable heating unit that provides supplemental or targeted warmth without permanent installation. Depending on the type, it generates heat using electricity, propane, natural gas, or kerosene and distributes it through radiant or forced-air heating.Portable heaters are commonly used in warehouses, workshops, construction sites, garages, and other commercial or residential spaces.
What types of Portable Heaters are available, and which Fuel Type is the best for your heating needs?
Portable heaters are available in electric, propane, natural gas, and kerosene models, each suited to different applications. The best fuel type depends on the heating capacity needed, the available power or fuel supply, ventilation, and whether the space is occupied.Electric: ideal for indoor spaces with adequate electrical capacity.Propane, natural gas, and kerosene: high heat output for construction sites, warehouses, and industrial environments.
What is the difference between direct-fired and indirect-fired Portable Heaters?
Direct-fired portable heaters release heat and combustion byproducts directly into the heated space, so they are best suited to well-ventilated areas. Indirect-fired heaters use a heat exchanger to deliver clean heated air while exhausting combustion gases outside.Indirect-fired models are ideal for enclosed or occupied spaces where cleaner heated air is needed.
What is the difference between radiant and forced-air Portable Heaters?
Radiant portable heaters warm people and objects directly, making them ideal for targeted heating in work areas. Forced-air portable heaters use a fan to circulate warm air throughout a space, making them better suited to larger areas such as warehouses, workshops, and construction sites.The best option depends on whether localized warmth or broader air circulation is needed.
Can Portable Heaters be used both indoors and outdoors?
Yes, portable heaters are available for both indoor and outdoor use, but the appropriate type depends on the fuel source, ventilation, and application.Indoors: electric and approved indirect-fired heaters are commonly used.Outdoors or well-ventilated areas: many direct-fired models are better suited.Always follow the manufacturer's safety and ventilation requirements.
Do Portable Heaters require ventilation?
Ventilation requirements for portable heaters depend on the fuel type and heating design. Direct-fired heaters require adequate ventilation because they release combustion byproducts into the heated space, while indirect-fired models exhaust those gases outdoors.Electric heaters do not produce combustion gases and generally do not require combustion ventilation.
How long will Portable Heaters run on a full fuel tank?
Runtime on a full tank depends on tank capacity, fuel type, heat output, and fuel consumption rate. Larger tanks generally provide longer operation, while higher BTU settings use fuel more quickly.As a rough estimate, runtime in hours = tank size in gallons × fuel BTU per gallon ÷ heater BTU per hour. Propane contains about 91,500 BTU per gallon and kerosene about 135,000. Check the manufacturer's specifications for actual runtime at different heat settings.
What safety features should I look for when purchasing a Portable Heater?
Look for overheat protection, automatic shutoff, flame failure protection, and tip-over protection where applicable. Fuel-fired models should also have safety controls that prevent fuel leaks or unsafe operation, along with clear ventilation requirements.Choose a heater designed for the intended environment and follow the manufacturer's safety guidelines.
How often should Portable Heaters be cleaned and maintained?
Inspect a portable heater before each use and clean it regularly to remove dust, debris, and buildup that can affect performance. Check the fuel lines, filters, burners, electrical connections, and safety controls according to the manufacturer's maintenance schedule.Regular maintenance ensures safe operation, reliable heating, and longer equipment life.
What is the difference between a Portable Heater and a temporary heating system?
A portable heater is a self-contained unit that provides targeted or supplemental heat, while a temporary heating system typically refers to larger equipment used to heat entire buildings or job sites.Portable heaters: ideal for individual work areas, workshops, and smaller spaces.Temporary heating systems: better suited to large construction projects, warehouses, and industrial facilities that need broader coverage.
Did you find what you were looking for?