LB White 500,000 BTU LINK Capable Diesel Indirect-Fired Portable Heater | 120V

SAVE $10,909.00
By

LB White

In stock
Model

Foreman 500 Oil LINK Capable

ID

153826

Was $18,879.00 Your Low Price Special Price $7,970.00
Ships in 2-3 Weeks
Free Shipping
 

LINK™ Monitoring Upgrade Capability 500,000 BTU Indirect-Fired Portable Oil Heater for Construction & Industrial Applications

The L.B. White FOREMAN® 500 Oil 2.0 LINK™ Capable is a 500,000 BTU/h portable indirect-fired oil heater designed to provide high-output supplemental heat for construction sites, industrial facilities, warehouses, loading docks, and suitable temporary enclosures. Operating on #1 or #2 diesel fuel, this ductable heating system combines a Beckett® burner, a fully welded heat exchanger, and high-volume forced-air circulation to deliver heated air while keeping combustion exhaust separate from the supply air. Its nominal 61-gallon onboard fuel tank, dual 12-inch heated-air outlets, 20-inch air-recirculation inlet, and portable industrial frame support flexible deployment across demanding job sites. The LINK™ Capable configuration supports a future upgrade to L.B. White's LINK™ equipment monitoring platform through the installation of compatible conversion hardware and harness components, helping equipment managers improve fleet visibility and coordinate maintenance.

Key Benefits

  • 500,000 BTU/h Heating Capacity – Delivers high-output supplemental heat for suitable construction, industrial, and temporary enclosure applications.
  • Indirect-Fired Heating Technology – Uses a fully welded heat exchanger to separate combustion exhaust from the heated air supplied to the work area.
  • 3,457 CFM Blower Output – Provides high-volume forced-air circulation to support heated-air distribution through compatible ducting.
  • Dual 12-Inch Duct Outlets – Supports flexible heat distribution through two discharge connections for designated work areas.
  • #1 and #2 Diesel Fuel Compatibility – Provides fuel flexibility for approved oil-fired heating applications.
  • 61-Gallon Nominal Fuel Tank – Provides integrated fuel storage for temporary heating applications.
  • 20-Inch Air-Recirculation Inlet – Supports compatible air-recirculation configurations for flexible heating-system setup.
  • LINK™ Capable Connectivity – Provides an upgrade path to the LINK™ equipment monitoring platform with the required conversion kit and compatible monitoring hardware.
  • Portable Industrial Construction – Includes wheels, a handle, a single-point lifting bail, and forklift pockets to facilitate transportation and positioning.
  • Two-Year Manufacturer Warranty – Subject to the manufacturer's applicable written warranty terms, conditions, and exclusions.

500,000 BTU/h High-Output Heating Performance

The L.B. White FOREMAN® 500 Oil 2.0 delivers a rated heating input of 500,000 BTU/h for demanding temporary-heating applications. Its forced-air system has a published blower output of 3,457 cubic feet per minute (CFM), supporting distribution of heated air through compatible ducting. The fully welded heat exchanger transfers heat from the combustion process to the circulating air while keeping combustion exhaust separate from the heated supply air. This indirect-fired design supports applications requiring heated air for construction and industrial work areas. Actual heating coverage depends on ambient temperature, enclosure dimensions, insulation, air infiltration, duct configuration, and other site conditions.

Indirect-Fired Diesel Heating Technology

The L.B. White FOREMAN® 500 Oil 2.0 uses a Beckett® oil burner and indirect-fired heating technology to provide high-output supplemental heat. The burner heats the fully welded heat exchanger, while the integrated fan moves air across the exchanger to deliver heated air into the intended space. Combustion gases are discharged separately through the exhaust system rather than being mixed directly with the heated supply air. The heater operates on #1 or #2 diesel fuel, providing flexibility for approved oil-fired applications. Proper combustion-air provisions, exhaust routing, fuel connections, and installation clearances are essential for safe operation. Install and operate the heater according to the current manufacturer's instructions and applicable safety requirements.

3,457 CFM Blower Output & Dual-Duct Heat Distribution

The L.B. White FOREMAN® 500 Oil 2.0 features a high-volume blower rated at 3,457 CFM. Two 12-inch outlet duct connections provide flexibility for distributing heated air to designated areas. Manufacturer documentation specifies a maximum duct length of 100 feet per outlet, subject to the approved installation configuration and maximum outlet static pressure of 2.5 inches water column. The heater also features a 20-inch air-recirculation inlet for compatible recirculation arrangements. An optional 16-inch duct adapter kit is available for approved alternative duct configurations. Use manufacturer-approved ducting and accessories, maintain unobstructed airflow, and follow the current owner's manual for duct lengths, pressure limitations, and connection requirements.

Portable Design & Flexible Installation

The L.B. White FOREMAN® 500 Oil 2.0 features a portable industrial design intended for temporary heating applications. Manufacturer-published dimensions are approximately 84.5 inches long, 33.25 inches wide, and 52.5 inches high. The listed unit weight is approximately 829 lb, with a shipping weight of approximately 979 lb. Integrated wheels, a handle, a single-point lifting bail, and forklift pockets support transportation and positioning at suitable work sites. Installation requires a compatible diesel fuel supply, an appropriate electrical connection, approved heated-air ducting, and a properly installed exhaust system. Position the heater securely on a stable surface, maintain specified clearances, and follow the manufacturer's handling, installation, and operating instructions.

Fuel Management & Operating Duration

The L.B. White FOREMAN® 500 Oil 2.0 operates on #1 or #2 diesel fuel and incorporates a nominal 61-gallon onboard fuel tank. Its published maximum firing rate is approximately 3.6 gallons per hour. Based on nominal tank capacity and maximum published consumption, the theoretical operating duration is approximately 16.9 hours; actual runtime varies with operating conditions and usable fuel volume. L.B. White identifies remote oil hookup kit Part No. 500-131261 for compatible FOREMAN 230 and 500 oil models. Where an external fuel supply is required, use the approved kit and follow the manufacturer's instructions for installation, fuel-line routing, and safe operation. Use only approved fuel and never refill the tank while the heater is operating or hot.

Controls, Temperature Management & Electrical Connection

The L.B. White FOREMAN® 500 Oil 2.0 supports compatible remote thermostat operation for temperature management. An optional weather-resistant NEMA 4X thermostat with a 25-foot cord is available for compatible configurations. The heater uses a 120 V, 60 Hz, single-phase electrical supply. Verify the exact current draw, startup requirements, overcurrent protection, grounding, and connection configuration against the heater's data plate and current owner's manual before installation. The manufacturer's manual specifies a minimum 20 A breaker for the FOREMAN 500 Oil configuration. Electrical installation must follow the manufacturer's instructions and applicable electrical codes.

Construction, Warehouse & Industrial Applications

The L.B. White FOREMAN® 500 Oil 2.0 is designed for supplemental heating in construction sites, warehouses, industrial facilities, loading docks, and suitable temporary enclosures requiring indirect-fired heat. Its 500,000 BTU/h heating input, high-volume blower, and dual duct outlets support applications requiring substantial heated-air delivery. The indirect-fired design helps keep combustion gases separate from the heated supply air, while the onboard fuel tank supports portable deployment. Its industrial frame, lifting bail, and forklift pockets facilitate handling at suitable job sites. Confirm the heating capacity, electrical supply, duct configuration, fuel availability, and exhaust installation requirements for the intended application before operation.

LINK™ Capable Equipment Monitoring & Fleet Management

The L.B. White FOREMAN® 500 Oil 2.0 LINK™ Capable can be connected to the L.B. White LINK™ equipment monitoring platform using the required conversion kit and compatible telematics module. L.B. White specifies conversion kit Part No. 500-134313A for the LINK™ Capable FOREMAN Oil 2.0 configuration. Unlike LINK™ Ready models, the LINK™ Capable configuration requires additional heater wiring and harness components for connection to the monitoring module. Once compatible hardware is installed and the service is activated, the LINK™ platform can provide equipment information including GPS location, runtime, operating status, call-for-heat status, fuel-flow status, and telematics voltage. The web-based dashboard also supports critical alerts and maintenance notifications. Users can access the platform from internet-connected computers, tablets, and mobile devices. Confirm hardware compatibility, installation requirements, and subscription terms with L.B. White or an authorized dealer before ordering. LINK™ provides monitoring and reporting, not remote heater on/off control.

Mobility & Deployment

The L.B. White FOREMAN® 500 Oil 2.0 measures approximately 84.5 inches long, 33.25 inches wide, and 52.5 inches high. Its wheels, handle, single-point lifting bail, and forklift pockets support relocation between suitable temporary-heating locations. With a listed unit weight of approximately 829 lb, appropriate lifting equipment and handling procedures are essential when loading, unloading, or transporting the heater. Position the unit on a stable surface, maintain specified clearances, and secure it against unintended movement. Route ducting, exhaust components, fuel connections, and electrical supply to prevent damage and trip hazards. Shut down the heater, disconnect electrical power as directed, and allow hot components to cool before moving, servicing, or storing the equipment. Follow the manufacturer's instructions for fuel handling and transport.

Safety, Service & Maintenance

The L.B. White FOREMAN® 500 Oil 2.0 incorporates a Beckett® burner, a fully welded heat exchanger, and a separate combustion exhaust system. The indirect-fired design helps prevent direct mixing of combustion gases with the heated supply air. The FOREMAN Oil 2.0 series is designed for industrial and construction heating applications and is subject to the manufacturer's applicable certification and listing requirements. Inspect the burner, fuel tank, fuel lines, filter, electrical connections, fan, heat exchanger, ducting, and exhaust components before operation. Check the fuel system for leaks and ensure the exhaust system is installed according to the manufacturer's instructions. Maintain required clearances and unobstructed airflow, and remove accumulated dust or debris as directed. Combustion exhaust must be discharged safely through the approved exhaust system. Disconnect electrical power and allow hot components to cool before servicing. Follow the current owner's manual for fuel-filter replacement, burner maintenance, cleaning, inspection, and troubleshooting. Repairs to fuel, electrical, burner, and exhaust systems must be performed by appropriately qualified personnel. Never bypass safety devices or operate the heater with damaged components.

Warranty

The L.B. White FOREMAN® 500 Oil 2.0 is subject to the manufacturer's applicable written warranty policy. Refer to L.B. White's current warranty documentation for coverage details, exclusions, registration requirements, and installation, operation, and maintenance conditions. Warranty eligibility may depend on compliance with the manufacturer's instructions and use of approved fuel and replacement components. Confirm the current warranty terms with L.B. White or an authorized dealer before purchase.

Recommended Accessories

  • LINK™ Capable Conversion Kit – Manufacturer Part No. 500-134313A. Provides the required heater wiring and harness components for connecting a compatible FOREMAN Oil 2.0 LINK™ Capable model to the LINK™ monitoring system.
  • LINK™ Telematics Module – Required compatible monitoring hardware for equipment connectivity. Verify the module, subscription, and activation requirements with L.B. White.
  • Remote Thermostat, NEMA 4X, with 25-Foot Cord – Manufacturer accessory Part No. 500-30125, as identified in the applicable FOREMAN Oil manual. Verify the accessory configuration before ordering.
  • 12-Inch Fire-Retardant Duct, 25-Foot – Manufacturer accessory Part No. 30052, supplied with a clamp. Verify the outlet connection and approved duct arrangement.
  • 20-Inch Recirculating Duct, 25-Foot – Manufacturer accessory Part No. 30053, supplied with a clamp. Confirm compatibility with the FOREMAN 500 Oil 2.0 air-recirculation inlet.
  • 16-Inch Fire-Retardant Duct, 25-Foot – Manufacturer accessory Part No. 30076, supplied with a clamp. Verify compatibility with the approved duct adapter configuration.
  • 16-Inch Duct Adapter Kit – Manufacturer accessory Part No. 30902. Confirm compatibility with the FOREMAN 500 Oil 2.0 and the intended duct arrangement.
  • Remote Oil Hookup Kit – Manufacturer Part No. 500-131261, listed for compatible FOREMAN 230 and 500 oil models. Supports connection to an approved remote fuel supply when installed according to the manufacturer's instructions.
  • Replacement Fuel Filter and Burner Components – Use manufacturer-approved replacement parts selected from the official parts documentation for the specific heater configuration.

Reliable Fleet Monitoring Upgrade with the L.B. White FOREMAN® 500 Oil 2.0 LINK™ Capable

Experience high-output temporary heating with the L.B. White FOREMAN® 500 Oil 2.0 LINK™ Capable Portable Heater. Combining 500,000 BTU/h heating input with high-volume forced-air circulation, a nominal 61-gallon onboard fuel tank, dual 12-inch discharge outlets, and compatibility with #1 or #2 diesel fuel, this industrial heating system provides flexible heat distribution for suitable construction and industrial applications. Its fully welded heat exchanger separates combustion exhaust from the heated supply air, while its wheeled frame, lifting bail, forklift pockets, and upgrade path to LINK™ equipment monitoring support flexible deployment and equipment management.

More Information
LB White 500,000 BTU LINK Capable Diesel Indirect-Fired Portable Heater | 120V
FeatureSpec
SKUForeman 500 Oil LINK Capable
Weight (in lbs)979
Brand/ManufacturerLB White
Heating BTU500,000
Maximum CFM3,457
Horsepower1.5 Motor Horsepower
Electrical120 Volts | 60 Hz | 1 Phase
Operating ModeHeating
Fuel TypeDiesel
ColorWhite
Length94"
Height53″
Width32″
Warranty2-year warranty and lifetime of technical support.
Resources You will need Adobe Acrobat Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:LB White 500,000 BTU LINK Capable Diesel Indirect-Fired Portable Heater | 120V
Your Rating
Customer Questions
What is a Portable Heater, and how does it work?
A portable heater is a movable heating unit that provides supplemental or targeted warmth without permanent installation. Depending on the type, it generates heat using electricity, propane, natural gas, or kerosene and distributes it through radiant or forced-air heating.Portable heaters are commonly used in warehouses, workshops, construction sites, garages, and other commercial or residential spaces.
What types of Portable Heaters are available, and which Fuel Type is the best for your heating needs?
Portable heaters are available in electric, propane, natural gas, and kerosene models, each suited to different applications. The best fuel type depends on the heating capacity needed, the available power or fuel supply, ventilation, and whether the space is occupied.Electric: ideal for indoor spaces with adequate electrical capacity.Propane, natural gas, and kerosene: high heat output for construction sites, warehouses, and industrial environments.
What is the difference between direct-fired and indirect-fired Portable Heaters?
Direct-fired portable heaters release heat and combustion byproducts directly into the heated space, so they are best suited to well-ventilated areas. Indirect-fired heaters use a heat exchanger to deliver clean heated air while exhausting combustion gases outside.Indirect-fired models are ideal for enclosed or occupied spaces where cleaner heated air is needed.
What is the difference between radiant and forced-air Portable Heaters?
Radiant portable heaters warm people and objects directly, making them ideal for targeted heating in work areas. Forced-air portable heaters use a fan to circulate warm air throughout a space, making them better suited to larger areas such as warehouses, workshops, and construction sites.The best option depends on whether localized warmth or broader air circulation is needed.
Can Portable Heaters be used both indoors and outdoors?
Yes, portable heaters are available for both indoor and outdoor use, but the appropriate type depends on the fuel source, ventilation, and application.Indoors: electric and approved indirect-fired heaters are commonly used.Outdoors or well-ventilated areas: many direct-fired models are better suited.Always follow the manufacturer's safety and ventilation requirements.
Do Portable Heaters require ventilation?
Ventilation requirements for portable heaters depend on the fuel type and heating design. Direct-fired heaters require adequate ventilation because they release combustion byproducts into the heated space, while indirect-fired models exhaust those gases outdoors.Electric heaters do not produce combustion gases and generally do not require combustion ventilation.
How long will Portable Heaters run on a full fuel tank?
Runtime on a full tank depends on tank capacity, fuel type, heat output, and fuel consumption rate. Larger tanks generally provide longer operation, while higher BTU settings use fuel more quickly.As a rough estimate, runtime in hours = tank size in gallons × fuel BTU per gallon ÷ heater BTU per hour. Propane contains about 91,500 BTU per gallon and kerosene about 135,000. Check the manufacturer's specifications for actual runtime at different heat settings.
What safety features should I look for when purchasing a Portable Heater?
Look for overheat protection, automatic shutoff, flame failure protection, and tip-over protection where applicable. Fuel-fired models should also have safety controls that prevent fuel leaks or unsafe operation, along with clear ventilation requirements.Choose a heater designed for the intended environment and follow the manufacturer's safety guidelines.
How often should Portable Heaters be cleaned and maintained?
Inspect a portable heater before each use and clean it regularly to remove dust, debris, and buildup that can affect performance. Check the fuel lines, filters, burners, electrical connections, and safety controls according to the manufacturer's maintenance schedule.Regular maintenance ensures safe operation, reliable heating, and longer equipment life.
What is the difference between a Portable Heater and a temporary heating system?
A portable heater is a self-contained unit that provides targeted or supplemental heat, while a temporary heating system typically refers to larger equipment used to heat entire buildings or job sites.Portable heaters: ideal for individual work areas, workshops, and smaller spaces.Temporary heating systems: better suited to large construction projects, warehouses, and industrial facilities that need broader coverage.
Did you find what you were looking for?
blockboard tech