LB White 500,000 BTU LINK Capable Dual Fuel Indirect-Fired Portable Heater | 120V

SAVE $3,356.50
By

LB White

In stock
Model

Foreman 500 DF LINK Capable

ID

153823

Was $11,556.50 Your Low Price Special Price $8,200.00
Ships in 2-3 Weeks
Free Shipping
 

High-Output 500,000 BTU Dual-Fuel Indirect-Fired Portable Heater for Construction & Industrial Applications with LINK™ Monitoring Upgrade Capability

The L.B. White FOREMAN® 500 DF 2.0 LINK™ Capable is a 500,000 BTU/h portable dual-fuel indirect-fired heater designed to provide high-output supplemental heating for construction sites, industrial facilities, warehouses, loading docks, and suitable temporary enclosures. Operating on liquid propane (LP) or natural gas (NG), this ductable heating system combines a Riello® burner, a fully welded heat exchanger, and high-volume forced-air circulation to deliver clean, dry heated air while keeping combustion exhaust separate from the supply air. Its dual 12-inch heated-air outlets, 20-inch air-recirculation inlet, and portable industrial frame support flexible deployment across demanding job sites. The LINK™ Capable configuration can be upgraded to support L.B. White's LINK™ equipment monitoring platform by installing the required conversion kit and compatible telematics hardware, helping equipment managers improve fleet visibility and coordinate maintenance.

Key Benefits

  • 500,000 BTU/h Heating Capacity – Delivers high-output supplemental heat for suitable construction, industrial, and temporary enclosure applications.
  • Dual-Fuel LP and Natural Gas Operation – Supports two approved fuel types, providing flexibility for different job-site gas supplies.
  • Indirect-Fired Heating Technology – Uses a fully welded heat exchanger to separate combustion exhaust from the heated air supplied to the workspace.
  • 3,457 CFM Blower Output – Provides high-volume forced-air circulation for distributing heat through compatible ducting.
  • Dual 12-Inch Duct Outlets – Supports flexible heated-air delivery through two discharge connections or an approved single-duct configuration.
  • 20-Inch Air-Recirculation Inlet – Accommodates compatible recirculation ducting for flexible system configurations.
  • LINK™ Capable Connectivity – Provides an upgrade path to connected equipment monitoring through the required conversion kit, wiring harness, and compatible telematics module.
  • Portable Industrial Construction – Features wheels, a handle, a single-point lifting bail, and forklift pockets to facilitate transportation and positioning.
  • Remote Thermostat Compatibility – Supports optional thermostat control for convenient temperature management.
  • Two-Year Manufacturer Warranty – Covered by L.B. White's published warranty, subject to applicable terms and conditions.

500,000 BTU/h High-Output Heating Performance

The L.B. White FOREMAN® 500 DF 2.0 delivers a rated heating input of 500,000 BTU/h for demanding temporary-heating applications. Its forced-air system provides a rated blower output of 3,457 cubic feet per minute (CFM), supporting distribution of heated air through compatible ducting. The fully welded heat exchanger transfers energy from the combustion process to the circulating air while keeping combustion exhaust separate from the heated supply air. This indirect-fired design is suitable for applications requiring heated air to be distributed into work areas without directly mixing burner exhaust into the supply stream. Actual heating coverage depends on ambient temperature, enclosure dimensions, insulation, air infiltration, duct configuration, and other site conditions.

Dual-Fuel Indirect-Fired Heating Technology

The L.B. White FOREMAN® 500 DF 2.0 uses a Riello® burner and indirect-fired heating technology to provide high-output supplemental heat. The burner heats the fully welded heat exchanger, while the integrated blower circulates air across the exchanger to deliver heated air into the intended space. Combustion gases are routed through a separate exhaust system rather than being mixed directly with the heated supply air. The dual-fuel configuration operates on liquid propane or natural gas, allowing flexibility where either approved fuel supply is available. Manufacturer-published maximum fuel consumption is approximately 23.0 lb/h for LP and 500 cubic feet per hour for natural gas. The specified minimum and maximum inlet gas pressures are 8 and 13.5 inches water column for both fuel types. Correct fuel selection, supply capacity, inlet pressure, combustion-air provisions, and exhaust installation are essential for safe operation. Follow the current L.B. White owner's manual and applicable fuel-gas codes.

3,457 CFM Blower Output & Dual-Duct Heat Distribution

The L.B. White FOREMAN® 500 DF 2.0 features a high-volume blower rated at 3,457 CFM. Two 12-inch outlet duct connections provide flexibility for distributing heated air to designated work areas. The manufacturer specifies a maximum duct length of up to 100 feet per outlet, subject to the approved installation configuration and a maximum outlet static pressure of 2.5 inches water column. The heater also features a 20-inch air-recirculation inlet for compatible recirculation arrangements. An optional 16-inch duct adapter kit, Part No. 30902, supports an approved single-duct configuration. Use manufacturer-approved ducting and adapters, maintain unobstructed airflow, and follow the current owner's manual for duct lengths, static-pressure limitations, and connection requirements.

Portable Design & Flexible Installation

The L.B. White FOREMAN® 500 DF 2.0 features a portable industrial design intended for temporary heating applications. Manufacturer-published dimensions for the FOREMAN 500 DF 2.0 are approximately 94 inches long, 32 inches wide, and 53 inches high. The listed unit weight is approximately 674 lb, with a shipping weight of approximately 852 lb. Integrated wheels, a handle, a single-point lifting bail, and forklift pockets support transportation and positioning at suitable work sites. The heater requires a compatible LP or natural gas supply, an appropriate electrical connection, approved heated-air ducting, and a properly installed exhaust system. Position the unit securely on a stable surface, maintain the specified clearances, and follow the manufacturer's instructions for fuel connections, duct installation, exhaust routing, lifting, and operation.

Fuel Management & Energy Consumption

The L.B. White FOREMAN® 500 DF 2.0 operates on liquid propane or natural gas, with maximum fuel consumption depending on the selected fuel. Manufacturer specifications list maximum LP consumption of approximately 23.0 lb/h and maximum natural gas consumption of approximately 500 cubic feet per hour. The published minimum and maximum inlet gas pressures are 8 and 13.5 inches water column for both fuel types. Adequate fuel supply capacity and pressure must be maintained during operation to support proper burner performance. L.B. White identifies a dual-fuel gas regulator, Part No. 25141, for compatible FOREMAN DF models. Natural gas installations may require different hose and regulator configurations depending on available supply pressure. Verify regulator selection, hose sizing, gas flow, inlet pressure, and installation requirements against the current manufacturer's documentation. All fuel connections must comply with applicable codes and be installed by appropriately qualified personnel.

Controls, Temperature Management & Electrical Connection

The L.B. White FOREMAN® 500 DF 2.0 supports compatible remote thermostat operation for convenient temperature management. An optional weather-resistant NEMA 4X thermostat with a 25-foot cord is available for compatible configurations. The heater requires a 120 V, 60 Hz, single-phase electrical supply and uses a 1.5 HP motor. Manufacturer-published electrical specifications list approximately 35 A starting current and 14.8 A continuous current. Because startup current is higher than continuous operating current, verify circuit capacity, overcurrent protection, grounding, and connection requirements against the unit nameplate and current owner's manual before installation. Electrical connections must comply with the manufacturer's instructions and applicable electrical codes.

Construction, Warehouse & Industrial Applications

The L.B. White FOREMAN® 500 DF 2.0 is designed for supplemental heating in construction sites, warehouses, industrial facilities, loading docks, and suitable temporary enclosures requiring indirect-fired heat. Its 500,000 BTU/h heating input, high-volume blower, dual duct outlets, and dual-fuel capability support applications requiring substantial heated-air delivery. The indirect-fired configuration helps keep combustion gases separate from the heated supply air, while the portable frame supports deployment where temporary heat is needed. The FOREMAN series is certified to applicable ANSI/CSA standards for the United States and Canada, according to the manufacturer's published product literature. Confirm that the heating capacity, gas supply, electrical connection, duct configuration, exhaust installation, and intended occupancy meet manufacturer requirements and applicable safety regulations.

LINK™ Capable Equipment Monitoring & Fleet Management

The L.B. White FOREMAN® 500 DF 2.0 LINK™ Capable can be connected to the L.B. White LINK™ equipment monitoring platform using the manufacturer-specified conversion kit, wiring harness, and compatible telematics module. For the FOREMAN 500/750 DF 2.0 LINK™ Capable configuration, L.B. White specifies conversion kit Part No. 500-134313A. Unlike LINK™ Ready heaters, LINK™ Capable units require additional heater wiring and harness components to establish the connection. The manufacturer's LINK™ Capable installation instructions describe an installation process of approximately 20–30 minutes. The LINK™ system provides access to a web-based dashboard for viewing information such as GPS location, runtime, heater operating status, call-for-heat status, fuel-flow status, and telematics voltage. Users can configure critical alerts and maintenance notifications to support fleet management and service planning. The system is accessible through compatible internet-connected computers, tablets, and mobile devices. Confirm the conversion kit, hardware compatibility, activation requirements, and current subscription terms with L.B. White or an authorized dealer. LINK™ monitoring does not itself provide remote heater on/off control.

Mobility & Deployment

The L.B. White FOREMAN® 500 DF 2.0 measures approximately 94 inches long, 32 inches wide, and 53 inches high, with a listed unit weight of approximately 674 lb. Its wheels, handle, single-point lifting bail, and forklift pockets support relocation between suitable temporary-heating locations. Appropriate lifting equipment and handling procedures are essential when loading, unloading, or transporting the heater. Position the unit on a stable surface, maintain the required clearances, and secure it against unintended movement. Route ducting, exhaust components, gas hoses, and electrical connections to prevent damage and trip hazards. Shut off the fuel supply, disconnect electrical power as directed, and allow hot components to cool before moving, cleaning, or servicing the equipment.

Safety, Service & Maintenance

The L.B. White FOREMAN® 500 DF 2.0 incorporates a Riello® burner, a fully welded heat exchanger, and a separate combustion exhaust system. The indirect-fired design helps prevent direct mixing of combustion gases with the heated supply air. The FOREMAN DF series is certified to applicable ANSI/CSA standards for the United States and Canada, according to the manufacturer's published product literature. Inspect the burner, gas hoses, regulators, fuel connections, electrical components, fan, heat exchanger, ducting, and exhaust system before operation. Check gas connections for leaks using an approved procedure and verify that the selected fuel configuration matches the available supply. Maintain required clearances and unobstructed airflow, and ensure the exhaust system is installed according to the manufacturer's instructions. Combustion exhaust must be discharged safely through the approved exhaust system. Disconnect electrical power and allow hot components to cool before servicing. Follow the current owner's manual for inspection, cleaning, burner maintenance, and troubleshooting. Fuel-system and electrical repairs must be performed by appropriately qualified personnel. Never bypass safety devices or operate the heater with damaged components.

Warranty

The L.B. White FOREMAN® 500 DF 2.0 is covered by the manufacturer's published two-year warranty, subject to the applicable written warranty terms. Refer to L.B. White's current warranty documentation for coverage details, exclusions, registration requirements, and installation, operation, and maintenance conditions. Confirm the warranty terms applicable to the specific model and configuration with L.B. White or an authorized dealer before purchase.

Recommended Accessories

  • LINK™ Capable Conversion Kit – Manufacturer Part No. 500-134313A. Provides the heater wiring and harness components required to connect compatible FOREMAN 500/750 DF 2.0 LINK™ Capable models to the LINK™ monitoring system.
  • LINK™ Telematics Module – Required compatible monitoring hardware for equipment connectivity. Verify the correct module, activation process, and subscription terms with L.B. White.
  • Remote Thermostat, NEMA 4X, with 25-Foot Cord – Manufacturer accessory Part No. 30125. Supports remote temperature control when configured according to the manufacturer's instructions.
  • 12-Inch Fire-Retardant Duct, 25-Foot – Manufacturer accessory Part No. 30052, supplied with a clamp. Verify the outlet connection and approved duct arrangement.
  • 20-Inch Recirculating Duct, 25-Foot – Manufacturer accessory Part No. 30053, supplied with a clamp. Supports compatible air-recirculation configurations.
  • 16-Inch Fire-Retardant Duct, 25-Foot – Manufacturer accessory Part No. 30076, supplied with a clamp. Verify compatibility with the approved duct adapter configuration.
  • 16-Inch Duct Adapter Kit – Manufacturer accessory Part No. 30902. Supports compatible single-duct configurations; verify the required setup before ordering.
  • 3/4-Inch-by-15-Foot Gas Hose – Manufacturer accessory Part No. 25965, listed for compatible FOREMAN 230/500 models. Verify fuel type, connection size, and supply requirements before ordering.
  • Dual-Fuel Gas Regulator – Manufacturer accessory Part No. 25141, listed for compatible FOREMAN DF models. Confirm regulator and hose requirements for the specific LP or natural gas installation.
  • 6-Inch Steel Exhaust Pipe Extension – Manufacturer accessory Part No. 30161, listed for compatible FOREMAN 230/500/750 DF models. Verify the required exhaust configuration before ordering.
  • Rain Cap – Manufacturer accessory Part No. 30162, listed for compatible FOREMAN DF models. Use with the approved exhaust arrangement to help prevent water entry.
  • Heater Stacking Kit – Manufacturer accessory Part No. 30903, listed for FOREMAN 500 and 750 models. Confirm approved stacking and storage arrangements with the current owner's manual.

High-Output Dual-Fuel Heating with the L.B. White FOREMAN® 500 DF 2.0 LINK™ Capable

Experience high-output indirect-fired heating with the L.B. White FOREMAN® 500 DF 2.0 LINK™ Capable Portable Heater. Combining 500,000 BTU/h heating input with LP and natural gas compatibility, a Riello® burner, a fully welded heat exchanger, and 3,457 CFM blower output, this industrial heating system provides flexible supplemental heat for suitable construction and industrial applications. Its dual 12-inch discharge outlets, 20-inch air-recirculation inlet, portable frame, lifting bail, and forklift pockets support flexible heat distribution and job-site deployment. With the required conversion kit and telematics hardware, the LINK™ Capable configuration also provides a pathway to connected equipment monitoring for improved fleet visibility and maintenance coordination.

More Information
LB White 500,000 BTU LINK Capable Dual Fuel Indirect-Fired Portable Heater | 120V
FeatureSpec
SKUForeman 500 DF LINK Capable
Weight (in lbs)829
Brand/ManufacturerLB White
Heating BTU500,000
Maximum CFM3,457
Horsepower1.5 Motor Horsepower
Electrical120 Volts | 60 Hz | 1 Phase
Operating ModeHeating
Fuel TypePropane, Natural Gas, Multi-Fuel
ColorWhite
Length94"
Height53″
Width32″
Warranty2-year warranty and lifetime of technical support.
Resources You will need Adobe Acrobat Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:LB White 500,000 BTU LINK Capable Dual Fuel Indirect-Fired Portable Heater | 120V
Your Rating
Customer Questions
What is a Portable Heater, and how does it work?
A portable heater is a movable heating unit that provides supplemental or targeted warmth without permanent installation. Depending on the type, it generates heat using electricity, propane, natural gas, or kerosene and distributes it through radiant or forced-air heating.Portable heaters are commonly used in warehouses, workshops, construction sites, garages, and other commercial or residential spaces.
What types of Portable Heaters are available, and which Fuel Type is the best for your heating needs?
Portable heaters are available in electric, propane, natural gas, and kerosene models, each suited to different applications. The best fuel type depends on the heating capacity needed, the available power or fuel supply, ventilation, and whether the space is occupied.Electric: ideal for indoor spaces with adequate electrical capacity.Propane, natural gas, and kerosene: high heat output for construction sites, warehouses, and industrial environments.
What is the difference between direct-fired and indirect-fired Portable Heaters?
Direct-fired portable heaters release heat and combustion byproducts directly into the heated space, so they are best suited to well-ventilated areas. Indirect-fired heaters use a heat exchanger to deliver clean heated air while exhausting combustion gases outside.Indirect-fired models are ideal for enclosed or occupied spaces where cleaner heated air is needed.
What is the difference between radiant and forced-air Portable Heaters?
Radiant portable heaters warm people and objects directly, making them ideal for targeted heating in work areas. Forced-air portable heaters use a fan to circulate warm air throughout a space, making them better suited to larger areas such as warehouses, workshops, and construction sites.The best option depends on whether localized warmth or broader air circulation is needed.
Can Portable Heaters be used both indoors and outdoors?
Yes, portable heaters are available for both indoor and outdoor use, but the appropriate type depends on the fuel source, ventilation, and application.Indoors: electric and approved indirect-fired heaters are commonly used.Outdoors or well-ventilated areas: many direct-fired models are better suited.Always follow the manufacturer's safety and ventilation requirements.
Do Portable Heaters require ventilation?
Ventilation requirements for portable heaters depend on the fuel type and heating design. Direct-fired heaters require adequate ventilation because they release combustion byproducts into the heated space, while indirect-fired models exhaust those gases outdoors.Electric heaters do not produce combustion gases and generally do not require combustion ventilation.
How long will Portable Heaters run on a full fuel tank?
Runtime on a full tank depends on tank capacity, fuel type, heat output, and fuel consumption rate. Larger tanks generally provide longer operation, while higher BTU settings use fuel more quickly.As a rough estimate, runtime in hours = tank size in gallons × fuel BTU per gallon ÷ heater BTU per hour. Propane contains about 91,500 BTU per gallon and kerosene about 135,000. Check the manufacturer's specifications for actual runtime at different heat settings.
What safety features should I look for when purchasing a Portable Heater?
Look for overheat protection, automatic shutoff, flame failure protection, and tip-over protection where applicable. Fuel-fired models should also have safety controls that prevent fuel leaks or unsafe operation, along with clear ventilation requirements.Choose a heater designed for the intended environment and follow the manufacturer's safety guidelines.
How often should Portable Heaters be cleaned and maintained?
Inspect a portable heater before each use and clean it regularly to remove dust, debris, and buildup that can affect performance. Check the fuel lines, filters, burners, electrical connections, and safety controls according to the manufacturer's maintenance schedule.Regular maintenance ensures safe operation, reliable heating, and longer equipment life.
What is the difference between a Portable Heater and a temporary heating system?
A portable heater is a self-contained unit that provides targeted or supplemental heat, while a temporary heating system typically refers to larger equipment used to heat entire buildings or job sites.Portable heaters: ideal for individual work areas, workshops, and smaller spaces.Temporary heating systems: better suited to large construction projects, warehouses, and industrial facilities that need broader coverage.
Did you find what you were looking for?
blockboard tech