LB White 750,000 BTU LINK Capable Diesel Indirect-Fired Portable Heater | 120V

SAVE $5,805.00
By

LB White

In stock
Model

Foreman 750 Oil LINK Capable

ID

153874

Was $18,705.00 Your Low Price Special Price $12,900.00
Ships in 2-3 Weeks
Free Shipping
 

Clean Heat Delivery 750,000 BTU Indirect-Fired Portable Oil Heater for Construction & Industrial Applications with LINK™ Monitoring Upgrade Capability

The L.B. White FOREMAN® 750 Oil 2.0 LINK™ Capable is a 750,000 BTU/h portable indirect-fired oil heater designed to provide high-output supplemental heating for construction sites, industrial facilities, warehouses, loading docks, and suitable temporary enclosures. Operating on #1 or #2 diesel fuel, this ductable heating system combines a Beckett® burner, a fully welded heat exchanger, and high-volume forced-air circulation to deliver heated air while keeping combustion exhaust separate from the supply air. Its 60-gallon onboard fuel tank, dual 12-inch heated-air outlets, 20-inch air-recirculation inlet, and portable industrial frame support flexible deployment across demanding job sites. The LINK™ Capable configuration can be connected to L.B. White's LINK™ equipment monitoring platform using the required conversion kit and compatible telematics hardware, helping equipment managers improve fleet visibility and coordinate maintenance.

Key Benefits

  • 750,000 BTU/h Heating Capacity – Provides high-output supplemental heat for demanding construction, industrial, and temporary enclosure applications.
  • Indirect-Fired Heating Technology – Uses a fully welded heat exchanger to separate combustion exhaust from the heated air supplied to the work area.
  • 4,280 CFM Blower Output – Provides high-volume forced-air circulation to support heated-air distribution through compatible ducting.
  • Dual 12-Inch Duct Outlets – Supports flexible heat distribution through two discharge connections or an approved single-duct configuration.
  • 60-Gallon Onboard Fuel Tank – Provides integrated fuel storage for temporary heating deployments.
  • LINK™ Capable Connectivity – Provides an upgrade path to connected equipment monitoring through the required conversion kit, wiring harness, and compatible telematics module.
  • Portable Industrial Construction – Features wheels, a handle, a single-point lifting bail, and forklift pockets to facilitate transportation and positioning.
  • Remote Thermostat Compatibility – Supports optional thermostat control for convenient temperature management.
  • Two-Year Manufacturer Warranty – Supported by L.B. White's published warranty, subject to applicable written terms and conditions.

750,000 BTU/h High-Output Heating Performance

The L.B. White FOREMAN® 750 Oil 2.0 delivers a rated heating input of 750,000 BTU/h for demanding temporary-heating applications. Its forced-air system features a blower output of 4,280 cubic feet per minute (CFM), supporting distribution of heated air through compatible ducting. The fully welded heat exchanger transfers energy from the combustion process to the circulating air while keeping combustion exhaust separate from the heated supply air. This indirect-fired design supports applications requiring heated air to be distributed into work areas without directly mixing burner exhaust into the supply stream. Actual heating coverage depends on ambient temperature, enclosure dimensions, insulation, air infiltration, duct configuration, and other site conditions.

Indirect-Fired Diesel Heating Technology

The L.B. White FOREMAN® 750 Oil 2.0 uses a Beckett® oil burner and indirect-fired heating technology to provide high-output supplemental heat. The burner heats the fully welded heat exchanger, while the integrated blower circulates air across the exchanger to deliver heated air into the intended space. Combustion gases are routed through a separate exhaust system rather than being mixed directly with the heated supply air. The heater operates on #1 or #2 diesel fuel, providing flexibility for approved oil-fired applications. Manufacturer-published maximum fuel consumption is approximately 5.4 gallons per hour. Proper combustion-air provisions, exhaust routing, fuel connections, and installation clearances are essential for safe operation. Install and operate the heater according to the current manufacturer's instructions and applicable safety requirements.

4,280 CFM Blower Output & Dual-Duct Heat Distribution

The L.B. White FOREMAN® 750 Oil 2.0 features a high-volume blower rated at 4,280 CFM. Two 12-inch outlet duct connections provide flexibility for distributing heated air to designated work areas. Follow the manufacturer's approved duct configuration and maximum outlet static-pressure requirements when installing ductwork. The heater also features a 20-inch air-recirculation inlet for compatible recirculation arrangements. An optional 16-inch duct adapter kit, Part No. 30902, is available for compatible configurations. Use manufacturer-approved ducting and adapters, maintain unobstructed airflow, and follow the current owner's manual for duct lengths, static-pressure limitations, and connection requirements.

Portable Design & Flexible Installation

The L.B. White FOREMAN® 750 Oil 2.0 features a portable industrial design intended for temporary heating applications. Manufacturer-published shipping dimensions are approximately 88 inches long, 39 inches wide, and 60 inches high. The heater includes a single-point lifting bail, wheels, a handle, and forklift pockets to support transportation and positioning at suitable work sites. The FOREMAN 750 Oil is designed to accommodate connection to a remote fuel tank using an appropriate fuel connection. Installation requires an appropriate electrical connection, approved heated-air ducting, and a properly installed exhaust system. Position the unit securely on a stable surface, maintain specified clearances, and follow the manufacturer's instructions for fuel connections, duct installation, exhaust routing, lifting, and operation.

Fuel Management & Operating Duration

The L.B. White FOREMAN® 750 Oil 2.0 operates on #1 or #2 diesel fuel and incorporates a nominal 60-gallon onboard fuel tank. Its published maximum fuel consumption is approximately 5.4 gallons per hour. Based on nominal tank capacity and maximum published consumption, the theoretical operating duration is approximately 11.1 hours; actual runtime varies with operating conditions and usable fuel volume. All FOREMAN Oil heaters are shipped ready to operate from the onboard tank, and the FOREMAN 750 Oil is designed for connection to an approved remote fuel tank. Follow the manufacturer's instructions for fuel-line connections, shutoff valves, and leak checks. Use only approved fuel and never refill the tank while the heater is operating or hot.

Controls, Temperature Management & Electrical Connection

The L.B. White FOREMAN® 750 Oil 2.0 supports compatible remote thermostat operation for convenient temperature management. An optional weather-resistant NEMA 4X thermostat with a 25-foot cord, accessory Part No. 30125, is available for compatible configurations. The heater requires a 120 V, 60 Hz, single-phase electrical supply. Verify the exact motor rating, starting current, continuous current, grounding, and connection requirements against the unit nameplate and current owner's manual before installation. L.B. White specifies a minimum 20 A breaker for the FOREMAN 750 Oil configuration. Electrical connections must comply with the manufacturer's instructions and applicable electrical codes.

Construction, Warehouse & Industrial Applications

The L.B. White FOREMAN® 750 Oil 2.0 is designed for supplemental heating in construction sites, warehouses, industrial facilities, loading docks, and suitable temporary enclosures requiring indirect-fired heat. Its 750,000 BTU/h heating input, high-volume blower, and dual duct outlets support applications requiring substantial heated-air delivery. The indirect-fired configuration helps keep combustion gases separate from the heated supply air, while the onboard fuel tank supports portable deployment. The industrial frame, lifting bail, and forklift pockets facilitate handling at suitable job sites. The FOREMAN series is certified to applicable ANSI/CSA standards for the United States and Canada according to the manufacturer's published product literature. Confirm that the heating capacity, electrical supply, fuel availability, duct configuration, exhaust installation, and intended occupancy meet manufacturer requirements and applicable safety regulations.

LINK™ Capable Equipment Monitoring & Fleet Management

The L.B. White FOREMAN® 750 Oil 2.0 LINK™ Capable can be connected to the L.B. White LINK™ equipment monitoring platform using the manufacturer-specified conversion kit, wiring harness, and compatible telematics module. L.B. White identifies Part No. 500-133193 as the LINK™ Capable kit for compatible FOREMAN 230 Oil and 500/750 DF and Oil models. Unlike LINK™ Ready heaters, LINK™ Capable units require additional heater wiring and harness components to establish the connection. The manufacturer's LINK™ Capable installation process typically requires approximately 20–30 minutes. Once the compatible hardware is installed and the service is activated, the web-based dashboard can provide equipment information such as GPS location, runtime, heater operating status, call-for-heat status, fuel-flow status, and telematics voltage. Users can configure critical alerts and maintenance notifications to support fleet management and service planning. The platform is accessible through compatible internet-connected computers, tablets, and mobile devices. Confirm hardware compatibility, installation requirements, activation, and subscription terms with L.B. White or an authorized dealer before ordering. LINK™ monitoring does not itself provide remote heater on/off control.

Mobility & Deployment

The L.B. White FOREMAN® 750 Oil 2.0 features a portable industrial frame with wheels, a handle, a single-point lifting bail, and forklift pockets. These features support relocation between suitable temporary-heating locations. Use appropriate lifting equipment and handling procedures when loading, unloading, or transporting the heater. Position the unit on a stable surface, maintain required clearances, and secure it against unintended movement. Route ducting, exhaust components, fuel connections, and electrical supply to prevent damage and trip hazards. Shut down the heater, disconnect electrical power as directed, and allow hot components to cool before moving, cleaning, or servicing the equipment. Follow the manufacturer's instructions for fuel handling and transport.

Safety, Service & Maintenance

The L.B. White FOREMAN® 750 Oil 2.0 incorporates a Beckett® burner, a fully welded heat exchanger, and a separate combustion exhaust system. The indirect-fired design helps prevent direct mixing of combustion gases with the heated supply air. Inspect the burner, fuel tank, fuel lines, filter, electrical connections, fan, heat exchanger, ducting, and exhaust components before operation. Check the fuel system for leaks and ensure the exhaust system is installed according to the manufacturer's instructions. Maintain required clearances and unobstructed airflow, and remove accumulated dust or debris as directed. Combustion exhaust must be discharged safely through the approved exhaust system. Disconnect electrical power and allow hot components to cool before servicing. Follow the current owner's manual for fuel-filter replacement, burner maintenance, cleaning, inspection, and troubleshooting. Repairs to fuel, electrical, burner, and exhaust systems must be performed by appropriately qualified personnel. Never bypass safety devices or operate the heater with damaged components.

Warranty

The L.B. White FOREMAN® 750 Oil 2.0 is supported by the manufacturer's published two-year warranty, subject to the applicable written warranty terms. Refer to L.B. White's current warranty documentation for coverage details, exclusions, registration requirements, and installation, operation, and maintenance conditions. Confirm the warranty terms applicable to the specific model and configuration with L.B. White or an authorized dealer before purchase.

Recommended Accessories

  • LINK™ Capable Conversion Kit – Manufacturer Part No. 500-133193. Provides the heater wiring and harness components required to connect compatible FOREMAN Oil 2.0 LINK™ Capable models to the LINK™ monitoring system.
  • LINK™ Telematics Module – Compatible monitoring hardware required for equipment connectivity. Verify the correct module, activation process, and subscription terms with L.B. White.
  • Remote Thermostat, NEMA 4X, with 25-Foot Cord – Manufacturer accessory Part No. 30125. Supports remote temperature control when configured according to the manufacturer's instructions.
  • 16-Inch Duct Adapter Kit – Manufacturer accessory Part No. 30902. Verify compatibility with the FOREMAN 750 Oil 2.0 and intended duct configuration before ordering.
  • 8-Inch Steel Exhaust Pipe Extension – Manufacturer accessory Part No. 30161A, listed for the FOREMAN 750 Oil model. Verify the required exhaust configuration before ordering.
  • Rain Cap – Manufacturer accessory Part No. 30162A, listed for the FOREMAN 750 Oil model. Use with the approved exhaust arrangement to help prevent water entry.
  • Remote Fuel-Tank Connection Components – The FOREMAN 750 Oil is designed to accommodate an approved remote fuel-tank connection. Verify the correct fittings and installation requirements with L.B. White.
  • Heater Stacking Kit – Manufacturer accessory Part No. 30903, listed for FOREMAN 500 and 750 models. Confirm approved stacking and storage arrangements with the current owner's manual.
  • Replacement Fuel Filter and Burner Components – Use manufacturer-approved replacement parts selected from the official parts documentation for the specific heater configuration.

High-Output Indirect-Fired Heat with the L.B. White FOREMAN® 750 Oil 2.0 LINK™ Capable

Experience high-output temporary heating with the L.B. White FOREMAN® 750 Oil 2.0 LINK™ Capable Portable Heater. Combining 750,000 BTU/h heating input with a high-volume blower, a 60-gallon onboard fuel tank, dual 12-inch discharge outlets, and compatibility with #1 or #2 diesel fuel, this industrial heating system provides flexible heat distribution for demanding construction and industrial applications. Its fully welded heat exchanger separates combustion exhaust from the heated supply air, while the portable frame, lifting bail, and forklift pockets support flexible deployment. With the required conversion kit and compatible telematics hardware, the LINK™ Capable configuration also provides a pathway to connected equipment monitoring for improved fleet visibility and maintenance coordination.

More Information
LB White 750,000 BTU LINK Capable Diesel Indirect-Fired Portable Heater | 120V
FeatureSpec
SKUForeman 750 Oil LINK Capable
Weight (in lbs)1000
Brand/ManufacturerLB White
Heating BTU750,000
Maximum CFM4,280
Horsepower2.0 Motor Horsepower
Electrical240 Volts | 60 Hz | 1 Phase
Operating ModeHeating
Fuel TypeDiesel
ColorWhite
Length94"
Height53″
Width32″
Warranty2-year warranty and lifetime of technical support.
Resources You will need Adobe Acrobat Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:LB White 750,000 BTU LINK Capable Diesel Indirect-Fired Portable Heater | 120V
Your Rating
Customer Questions
What is a Portable Heater, and how does it work?
A portable heater is a movable heating unit that provides supplemental or targeted warmth without permanent installation. Depending on the type, it generates heat using electricity, propane, natural gas, or kerosene and distributes it through radiant or forced-air heating.Portable heaters are commonly used in warehouses, workshops, construction sites, garages, and other commercial or residential spaces.
What types of Portable Heaters are available, and which Fuel Type is the best for your heating needs?
Portable heaters are available in electric, propane, natural gas, and kerosene models, each suited to different applications. The best fuel type depends on the heating capacity needed, the available power or fuel supply, ventilation, and whether the space is occupied.Electric: ideal for indoor spaces with adequate electrical capacity.Propane, natural gas, and kerosene: high heat output for construction sites, warehouses, and industrial environments.
What is the difference between direct-fired and indirect-fired Portable Heaters?
Direct-fired portable heaters release heat and combustion byproducts directly into the heated space, so they are best suited to well-ventilated areas. Indirect-fired heaters use a heat exchanger to deliver clean heated air while exhausting combustion gases outside.Indirect-fired models are ideal for enclosed or occupied spaces where cleaner heated air is needed.
What is the difference between radiant and forced-air Portable Heaters?
Radiant portable heaters warm people and objects directly, making them ideal for targeted heating in work areas. Forced-air portable heaters use a fan to circulate warm air throughout a space, making them better suited to larger areas such as warehouses, workshops, and construction sites.The best option depends on whether localized warmth or broader air circulation is needed.
Can Portable Heaters be used both indoors and outdoors?
Yes, portable heaters are available for both indoor and outdoor use, but the appropriate type depends on the fuel source, ventilation, and application.Indoors: electric and approved indirect-fired heaters are commonly used.Outdoors or well-ventilated areas: many direct-fired models are better suited.Always follow the manufacturer's safety and ventilation requirements.
Do Portable Heaters require ventilation?
Ventilation requirements for portable heaters depend on the fuel type and heating design. Direct-fired heaters require adequate ventilation because they release combustion byproducts into the heated space, while indirect-fired models exhaust those gases outdoors.Electric heaters do not produce combustion gases and generally do not require combustion ventilation.
How long will Portable Heaters run on a full fuel tank?
Runtime on a full tank depends on tank capacity, fuel type, heat output, and fuel consumption rate. Larger tanks generally provide longer operation, while higher BTU settings use fuel more quickly.As a rough estimate, runtime in hours = tank size in gallons × fuel BTU per gallon ÷ heater BTU per hour. Propane contains about 91,500 BTU per gallon and kerosene about 135,000. Check the manufacturer's specifications for actual runtime at different heat settings.
What safety features should I look for when purchasing a Portable Heater?
Look for overheat protection, automatic shutoff, flame failure protection, and tip-over protection where applicable. Fuel-fired models should also have safety controls that prevent fuel leaks or unsafe operation, along with clear ventilation requirements.Choose a heater designed for the intended environment and follow the manufacturer's safety guidelines.
How often should Portable Heaters be cleaned and maintained?
Inspect a portable heater before each use and clean it regularly to remove dust, debris, and buildup that can affect performance. Check the fuel lines, filters, burners, electrical connections, and safety controls according to the manufacturer's maintenance schedule.Regular maintenance ensures safe operation, reliable heating, and longer equipment life.
What is the difference between a Portable Heater and a temporary heating system?
A portable heater is a self-contained unit that provides targeted or supplemental heat, while a temporary heating system typically refers to larger equipment used to heat entire buildings or job sites.Portable heaters: ideal for individual work areas, workshops, and smaller spaces.Temporary heating systems: better suited to large construction projects, warehouses, and industrial facilities that need broader coverage.
Did you find what you were looking for?
blockboard tech