Dual-Fuel Indirect-Fired Heating 360,000 BTU Portable Heater for Construction & Industrial Applications

The L.B. White Journeyman® 360 DF is a 360,000 BTU/h portable dual-fuel indirect-fired heater designed to provide supplemental heat for construction sites, industrial facilities, warehouses, and suitable temporary work areas. Operating on liquid propane (LP) or natural gas (NG), this ductable heating system combines an indirect-fired heat exchanger, forced-air circulation, and dual discharge outlets to distribute heated air while keeping combustion exhaust separate from the supply air. Its portable wheeled construction, dual-fuel capability, and compatibility with approved ducting provide flexibility for demanding temporary-heating applications. Designed for construction heating, the Journeyman 360 DF offers an alternative to oil-fired heating equipment where an appropriate gas supply is available.

Key Benefits

  • 360,000 BTU/h Heating Capacity – Provides high-output supplemental heat for suitable construction and industrial applications.
  • Dual-Fuel LP and Natural Gas Operation – Supports liquid propane or natural gas, offering flexibility for different job-site fuel supplies.
  • Indirect-Fired Heating Technology – Separates combustion exhaust from the heated supply air through a heat exchanger.
  • Ductable Heat Distribution – Supports delivery of heated air to designated areas through compatible ducting.
  • Dual Discharge Outlets – Provides flexibility when directing heated air to multiple areas or using an approved single-duct configuration.
  • Adjustable Fuel Configuration – Includes a gas selector valve for selecting the approved LP or natural gas supply without requiring a fuel conversion kit.
  • Remote Thermostat Compatibility – Supports compatible thermostat control for convenient temperature management.
  • Portable Construction – Incorporates solid, flat-free wheels and a handle to facilitate movement between suitable work areas.
  • Industrial Heating Design – Supports temporary heating requirements where a high-capacity indirect-fired gas heater is appropriate.

360,000 BTU/h High-Output Heating Performance

The L.B. White Journeyman® 360 DF delivers a rated heating input of 360,000 BTU/h for demanding temporary-heating applications. Its forced-air system circulates air through the heat exchanger and distributes the resulting heated air through the discharge outlets. The indirect-fired configuration keeps combustion gases separate from the heated supply air, making the heater suitable for approved applications requiring ducted heat without direct mixing of burner exhaust into the delivered air. Actual heating coverage depends on ambient temperature, enclosure dimensions, insulation, air infiltration, duct configuration, and other site conditions.

Dual-Fuel Indirect-Fired Heating Technology

The L.B. White Journeyman® 360 DF operates on either liquid propane or natural gas using an indirect-fired combustion system. The burner heats the heat exchanger, while the integrated blower moves air across the exchanger to deliver heated air into the intended space. Combustion products are discharged through a separate exhaust system rather than being mixed directly into the heated supply air. A built-in gas selector valve allows the operator to select the approved fuel type without requiring a separate LP-to-NG conversion kit. The published inlet gas pressure requirement is 7 to 13.5 inches water column, measured at the heater regulator during operation. Correct gas pressure, fuel supply capacity, combustion-air provisions, and exhaust installation are essential for safe operation. Follow the current L.B. White owner's manual and applicable fuel-gas codes.

Forced-Air Distribution & Ducting Flexibility

The L.B. White Journeyman® 360 DF features a ductable forced-air design for distributing heated air throughout suitable temporary work areas. Its two discharge outlets allow flexible placement and heat delivery through compatible ducting. According to L.B. White's official Journeyman troubleshooting guidance, the heater can accommodate up to 100 feet of duct per discharge opening, subject to a maximum static pressure of 0.5 inches water column per opening. If only one outlet is ducted, the other outlet must remain open. Blocking an outlet to extend duct length beyond the approved limit can cause excessive static pressure and trip the high-limit switches. Use approved ducting, maintain unobstructed airflow, and follow the current owner's manual for outlet connections, duct lengths, and installation requirements.

Portable Design & Flexible Installation

The L.B. White Journeyman® 360 DF is designed for portable deployment at temporary-heating locations. Its wheeled frame and solid, flat-free wheels help facilitate movement across suitable job-site surfaces. The heater requires an appropriate LP or natural gas supply, a compatible electrical connection, approved heated-air ducting, and a properly installed exhaust system. Position the unit on a stable, level surface and maintain the clearances specified in the manufacturer's documentation. Confirm the exact model's dimensions, operating weight, lifting requirements, and connection locations from the current official specification sheet before planning transport or installation. Follow the owner's manual for fuel connections, exhaust routing, duct setup, and safe operation.

Fuel Management & Energy Consumption

The L.B. White Journeyman® 360 DF operates on liquid propane or natural gas. L.B. White's official technical support guidance indicates that the heater consumes approximately 4 gallons of propane per hour. Actual consumption and operating duration depend on the selected fuel, heat demand, supply conditions, and operating environment. For propane installations, tank vaporization capacity is an important consideration, particularly in cold weather. L.B. White recommends a minimum 420 lb propane tank when outdoor temperatures remain above 30°F and a 500-gallon tank when temperatures may fall below 30°F. These recommendations should be verified against the current owner's manual and the specific installation. The natural gas supply must also provide adequate flow and maintain the specified inlet pressure under operating conditions. Use approved gas hoses, regulators, and connections, and have fuel-system installation performed by qualified personnel.

Controls, Temperature Management & Electrical Connection

The L.B. White Journeyman® 360 DF supports compatible remote thermostat operation to help regulate heating according to the desired ambient temperature. The heater may operate without a thermostat when configured and used according to the manufacturer's instructions. The unit requires an appropriate electrical supply for its burner controls and fan. Verify the exact voltage, frequency, phase, current draw, plug configuration, and circuit requirements using the heater's data plate and current owner's manual before installation. Ensure that the electrical circuit is properly grounded and suitable for the heater's startup and continuous operating loads. Remote thermostat wiring and gas connections must be installed according to the manufacturer's instructions and applicable electrical and fuel-gas codes.

Construction, Warehouse & Industrial Applications

The L.B. White Journeyman® 360 DF is designed for temporary heating in buildings under construction, alteration, or repair, as well as suitable warehouses, industrial facilities, and job-site work areas. Its 360,000 BTU/h heating input and ductable configuration support applications requiring high-output supplemental heat. The indirect-fired design separates combustion exhaust from the heated supply air, while the dual-fuel system provides flexibility where LP or natural gas is available. The heater must be installed and operated in accordance with the manufacturer's application requirements, including appropriate exhaust routing, combustion-air provisions, gas pressure, and clearances. Confirm suitability for the intended occupancy and comply with all applicable fire, ventilation, and safety regulations.

Mobility & Deployment

The L.B. White Journeyman® 360 DF incorporates a portable frame and solid, flat-free wheels to support relocation between suitable temporary-heating locations. Its dual discharge outlets provide flexibility when routing compatible ductwork to designated areas. Position the heater on a stable surface, maintain the required clearances, and route gas hoses, exhaust components, ducting, and electrical connections to prevent damage and trip hazards. Shut off the fuel supply, disconnect electrical power as directed, and allow hot components to cool before moving, cleaning, or servicing the unit. Use appropriate handling equipment when required, and follow the manufacturer's instructions for transport and storage.

Safety, Service & Maintenance

The L.B. White Journeyman® 360 DF uses an indirect-fired heating system that separates combustion exhaust from the heated supply air. L.B. White provides a dedicated Journeyman 360 DF troubleshooting chart and an official owner's manual for inspection, servicing, and fault diagnosis. Inspect the burner, gas hoses, regulators, fuel connections, electrical components, fan, heat exchanger, ducting, and exhaust system before operation. Verify that the gas selector valve is set for the selected fuel and that the supply pressure remains within the required range during operation. Check gas connections for leaks using an approved procedure, maintain unobstructed airflow, and ensure the exhaust system is installed correctly. L.B. White recommends an exhaust chimney with a minimum 5-foot vertical run and a rain cap to help protect the heat exchanger from water entry and reduce the risk of exhaust being drawn into the heater's air inlet. Follow the current owner's manual for cleaning, inspection, troubleshooting, and maintenance intervals. Disconnect electrical power and allow the unit to cool before servicing. Gas-system and electrical repairs must be performed by appropriately qualified personnel. Never bypass safety devices or operate the heater with damaged components.

Warranty

Warranty coverage for the L.B. White Journeyman® 360 DF is subject to the manufacturer's applicable written warranty policy. Consult L.B. White's current warranty documentation or contact an authorized dealer for the warranty duration, covered components, exclusions, registration requirements, and installation, operation, and maintenance conditions. Warranty eligibility may depend on compliance with the manufacturer's instructions and use of approved fuel-system components.

Recommended Accessories

  • Remote Thermostat – Use a compatible thermostat to support automatic temperature control. Verify the correct accessory and wiring requirements for the Journeyman 360 DF.
  • Heated-Air Ducting – Use compatible ducting for the discharge outlets. Follow L.B. White's maximum duct length and static-pressure requirements for each outlet.
  • LP Gas Hose – Select an appropriately rated hose compatible with the heater's fuel connection, required gas flow, supply pressure, and installation distance.
  • Gas Regulator – Provide a compatible regulator where required to maintain the specified inlet pressure of 7 to 13.5 inches water column during operation.
  • Exhaust Chimney Pipe – Use a compatible exhaust pipe arrangement that meets the manufacturer's required vertical run and installation instructions.
  • Exhaust Rain Cap – Use a compatible rain cap to help prevent water entry into the exhaust system and heat exchanger.
  • Electrical Supply or Generator – Provide an electrical source that meets the heater's model-specific voltage, frequency, current, grounding, and startup requirements.

High-Output Dual-Fuel Heating with the L.B. White Journeyman® 360 DF

Experience high-output indirect-fired heating with the L.B. White Journeyman® 360 DF Portable Heater. Combining 360,000 BTU/h heating input with dual-fuel LP and natural gas operation, ductable forced-air distribution, and two discharge outlets, this portable heating system provides flexible supplemental heat for suitable construction and industrial applications. Its indirect-fired design keeps combustion exhaust separate from the heated supply air, while its portable wheeled construction supports deployment wherever temporary heat is needed and a compatible gas supply is available.

More Information
LB White 360,000 BTU Dual Fuel Indirect-Fired Portable Heater | 120V
FeatureSpec
SKUJourneyman 360 DF
Weight (in lbs)445
Brand/ManufacturerLB White
Additional InformationFuel Consumption Max: LP 16.7 lb/hr, NG 230 cu. ft./hr
Heating BTU360,000
Maximum CFM2,000
Horsepower1/2 Motor Horsepower
Electrical120 Volts | 60 hz | 1 phase
Operating ModeHeating
Outlet Diameter12” (for two ducts - S) / 16” (for one duct - O)
Fuel TypePropane, Natural Gas, Multi-Fuel
CertificationU.S./Canadian Certification
Total Outlet2 Outlet Duct Connections
Length82"
Height50.5″
Width30.75″
WarrantyTwo-year warranty and lifetime of technical support.
Resources You will need Adobe Acrobat Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:LB White 360,000 BTU Dual Fuel Indirect-Fired Portable Heater | 120V
Your Rating
Customer Questions
What is a Portable Heater, and how does it work?
A portable heater is a movable heating unit that provides supplemental or targeted warmth without permanent installation. Depending on the type, it generates heat using electricity, propane, natural gas, or kerosene and distributes it through radiant or forced-air heating.Portable heaters are commonly used in warehouses, workshops, construction sites, garages, and other commercial or residential spaces.
What types of Portable Heaters are available, and which Fuel Type is the best for your heating needs?
Portable heaters are available in electric, propane, natural gas, and kerosene models, each suited to different applications. The best fuel type depends on the heating capacity needed, the available power or fuel supply, ventilation, and whether the space is occupied.Electric: ideal for indoor spaces with adequate electrical capacity.Propane, natural gas, and kerosene: high heat output for construction sites, warehouses, and industrial environments.
What is the difference between direct-fired and indirect-fired Portable Heaters?
Direct-fired portable heaters release heat and combustion byproducts directly into the heated space, so they are best suited to well-ventilated areas. Indirect-fired heaters use a heat exchanger to deliver clean heated air while exhausting combustion gases outside.Indirect-fired models are ideal for enclosed or occupied spaces where cleaner heated air is needed.
What is the difference between radiant and forced-air Portable Heaters?
Radiant portable heaters warm people and objects directly, making them ideal for targeted heating in work areas. Forced-air portable heaters use a fan to circulate warm air throughout a space, making them better suited to larger areas such as warehouses, workshops, and construction sites.The best option depends on whether localized warmth or broader air circulation is needed.
Can Portable Heaters be used both indoors and outdoors?
Yes, portable heaters are available for both indoor and outdoor use, but the appropriate type depends on the fuel source, ventilation, and application.Indoors: electric and approved indirect-fired heaters are commonly used.Outdoors or well-ventilated areas: many direct-fired models are better suited.Always follow the manufacturer's safety and ventilation requirements.
Do Portable Heaters require ventilation?
Ventilation requirements for portable heaters depend on the fuel type and heating design. Direct-fired heaters require adequate ventilation because they release combustion byproducts into the heated space, while indirect-fired models exhaust those gases outdoors.Electric heaters do not produce combustion gases and generally do not require combustion ventilation.
How long will Portable Heaters run on a full fuel tank?
Runtime on a full tank depends on tank capacity, fuel type, heat output, and fuel consumption rate. Larger tanks generally provide longer operation, while higher BTU settings use fuel more quickly.As a rough estimate, runtime in hours = tank size in gallons × fuel BTU per gallon ÷ heater BTU per hour. Propane contains about 91,500 BTU per gallon and kerosene about 135,000. Check the manufacturer's specifications for actual runtime at different heat settings.
What safety features should I look for when purchasing a Portable Heater?
Look for overheat protection, automatic shutoff, flame failure protection, and tip-over protection where applicable. Fuel-fired models should also have safety controls that prevent fuel leaks or unsafe operation, along with clear ventilation requirements.Choose a heater designed for the intended environment and follow the manufacturer's safety guidelines.
How often should Portable Heaters be cleaned and maintained?
Inspect a portable heater before each use and clean it regularly to remove dust, debris, and buildup that can affect performance. Check the fuel lines, filters, burners, electrical connections, and safety controls according to the manufacturer's maintenance schedule.Regular maintenance ensures safe operation, reliable heating, and longer equipment life.
What is the difference between a Portable Heater and a temporary heating system?
A portable heater is a self-contained unit that provides targeted or supplemental heat, while a temporary heating system typically refers to larger equipment used to heat entire buildings or job sites.Portable heaters: ideal for individual work areas, workshops, and smaller spaces.Temporary heating systems: better suited to large construction projects, warehouses, and industrial facilities that need broader coverage.
Did you find what you were looking for?