Your cookie preferences
We use cookies to remember your preferences and understand how shoppers use our site, helping us improve your shopping experience.
Read our privacy policyThe L.B. White Tradesman® K175 is a 175,000 BTU/h portable heater designed to provide high-output supplemental heating for construction sites, industrial work areas, agricultural facilities, and other suitable temporary-heating environments. Combining 175,000 BTU/h of heating capacity with direct-fired forced-air heating technology and an integrated 13-gallon fuel tank, this self-contained heating system delivers directional warmth while supporting flexible placement and relocation between work areas. Its comfort-control thermostat, electronic spark ignition, onboard fuel and pump-pressure gauges, and integrated wheels and handles support convenient operation, fuel monitoring, and transportation.
The L.B. White Tradesman® K175 delivers a rated heating capacity of 175,000 BTU/h for supplemental heating in suitable construction, industrial, and agricultural environments. Its forced-air system provides a rated heated-air output of 600 cubic feet per minute (CFM), helping distribute warmth toward the intended work area. The direct-fired design transfers combustion heat directly into the airstream, with manufacturer-stated fuel efficiency of 99.97%. Actual heating performance and coverage depend on ambient temperature, building construction, ventilation, air infiltration, and other site conditions.
The L.B. White Tradesman® K175 uses direct-fired forced-air heating technology with an integrated fuel tank. The manufacturer identifies 1-K kerosene as the primary fuel and also lists No. 1 and No. 2 diesel fuel and No. 1 fuel oil as approved alternatives. Combustion heats the air directly, delivering high-output warmth without an indirect-fired heat exchanger. The manufacturer specifies a direct-fired fuel efficiency of 99.97%. Because combustion products enter the heated airstream, adequate ventilation is essential. Operate the heater only in applications permitted by the manufacturer's instructions and applicable safety requirements. It must not be used to heat human living quarters or in unventilated areas.
The L.B. White Tradesman® K175 provides a rated heated-air output of 600 CFM. Its integrated fan circulates heated air toward the intended work area, supporting directional supplemental heating in suitable construction, industrial, and agricultural environments. The forced-air configuration helps distribute warmth beyond the immediate heater outlet. Keep the air inlet and discharge openings unobstructed during operation and maintain the clearances specified in the manufacturer's instructions. Do not attach ductwork unless the manufacturer expressly approves the configuration for this model.
The L.B. White Tradesman® K175 features a portable construction with an integrated 13-gallon fuel tank, wheels, and handles. Manufacturer-published dimensions are approximately 41.8 inches long, 23.1 inches wide, and 26.1 inches high, with a shipping weight of approximately 72 lb. Its self-contained fuel supply supports deployment without a separate external tank, while the wheels and handles facilitate transportation between suitable work areas. Position the heater on a stable, level surface and maintain all required clearances. Fuel handling, positioning, and operation must follow the manufacturer's instructions and applicable local codes.
The L.B. White Tradesman® K175 operates on 1-K kerosene and is also specified for No. 1 or No. 2 diesel fuel and No. 1 fuel oil. Its onboard fuel tank has a capacity of 13 gallons, with maximum fuel consumption of approximately 1.3 gallons per hour. The manufacturer lists a maximum operating time of approximately 10 hours per full tank under specified operating conditions. Actual runtime varies with operating conditions, fuel type, and available fuel. The unit uses a fuel pump with a rated pump pressure of 6.5 PSI and requires a 120 V, 60 Hz, single-phase electrical supply for fan and ignition operation. The manufacturer specifies a continuous operating current of 3.2 A and a motor rating of 1/4 horsepower. Use only approved fuels and verify electrical requirements against the current owner's manual and unit nameplate.
The L.B. White Tradesman® K175 includes a comfort-control thermostat, an on/off switch, dual-prong electronic spark ignition, and onboard fuel and pump-pressure gauges. The thermostat helps regulate heating operation according to the selected temperature, while the gauges support fuel monitoring and fuel-system maintenance. Manufacturer-published electrical specifications identify a 120 V, 60 Hz, single-phase supply and a continuous operating current of 3.2 A. Verify the factory-installed plug configuration, grounding, power cord requirements, and circuit capacity using the current owner's manual and unit nameplate before operation. Connect the heater to a suitable electrical supply and follow the manufacturer's startup and shutdown procedures.
The L.B. White Tradesman® K175 is designed for portable supplemental heating in suitable construction, industrial, and agricultural environments. Manufacturer product literature identifies Tradesman K heaters for construction worksites and agricultural facilities, including swine buildings. Its 175,000 BTU/h heating capacity, 600 CFM heated-air output, and integrated fuel tank support temporary heating where directional warmth and portable deployment are required. Because the heater is direct-fired, its application must comply with the manufacturer's ventilation requirements, fuel-burning equipment regulations, and site safety procedures.
The L.B. White Tradesman® K175 features integrated wheels and handles to facilitate movement and repositioning. With dimensions of approximately 41.8 inches long, 23.1 inches wide, and 26.1 inches high, and a shipping weight of approximately 72 lb, the unit is designed for portable deployment between suitable work areas. The integrated 13-gallon fuel tank reduces the need to transport a separate tank with the heater. Position the unit securely, maintain the required clearances, and follow the manufacturer's instructions when moving, refueling, or preparing the heater for storage. Disconnect the electrical supply and allow the heater to cool as directed before handling or servicing.
The L.B. White Tradesman® K175 features dual-prong electronic spark ignition, a comfort-control thermostat, fuel and pump-pressure gauges, and a threaded drain plug. These features support startup, operating monitoring, and routine maintenance. The manufacturer identifies CSA certification for the United States and Canada for the Tradesman K series. Inspect the heater, electrical cord, fuel tank, fittings, and fuel system before operation. Use only manufacturer-approved fuels, check fuel connections for leaks using an approved procedure, and maintain adequate ventilation and clearances from combustible materials. Keep the air inlet and discharge unobstructed, do not operate damaged equipment, and follow the owner's manual for cleaning, draining, servicing, and storage. Never bypass safety devices or use the heater in applications prohibited by the manufacturer.
Warranty coverage for the L.B. White Tradesman® K175 should be confirmed directly with L.B. White or an authorized dealer before purchase. Refer to the applicable written manufacturer warranty for coverage duration, exclusions, registration requirements, and any installation, operation, or maintenance conditions that apply to this model.
Experience dependable supplemental heating with the L.B. White Tradesman® K175 Portable Forced-Air Kerosene Heater. Combining 175,000 BTU/h heating capacity with 600 CFM heated-air output, an integrated 13-gallon fuel tank, electronic spark ignition, a comfort-control thermostat, and built-in fuel and pump-pressure gauges, this portable heater provides directional warmth for suitable construction, industrial, and agricultural applications. Its self-contained fuel supply, integrated wheels and handles, and durable construction support flexible deployment wherever direct-fired heating is appropriate and the required ventilation, fuel supply, and electrical connection are available.