Your cookie preferences
We use cookies to remember your preferences and understand how shoppers use our site, helping us improve your shopping experience.
Read our privacy policyThe L.B. White Tradesman® K210 is a commercial-grade portable forced-air kerosene heater designed to provide high-output supplemental heating for construction sites, industrial work areas, and other suitable temporary-heating environments. Delivering 210,000 BTU/h of heating output with a rated heated-air delivery of 650 CFM, this direct-fired heating system combines electronic spark ignition, an integrated 13-gallon fuel tank, and a comfort-control thermostat for convenient temperature management. Its onboard fuel and pressure gauges, heavy-duty enclosed motor, durable fuel fittings, and integrated wheels and handles support serviceability and relocation between work areas where temporary fuel-fired heating is appropriate.
The L.B. White Tradesman® K210 delivers a rated heating capacity of 210,000 BTU/h for supplemental heating in suitable construction, industrial, and agricultural environments. Its forced-air system provides a rated heated-air output of 650 cubic feet per minute (CFM), helping distribute warmth throughout the intended work area. The direct-fired design transfers combustion heat directly into the airstream, providing high-output heat without an indirect-fired heat exchanger. Actual heating performance and coverage depend on ambient temperature, building construction, ventilation, air infiltration, and other site conditions.
The L.B. White Tradesman® K210 uses direct-fired forced-air heating technology with an integrated fuel tank. The manufacturer identifies kerosene as the primary fuel and also lists No. 1 and No. 2 diesel fuel and No. 1 fuel oil as approved alternatives. Combustion heats the air directly, and the integrated fan distributes the heated airstream into the surrounding area. L.B. White specifies direct-fired fuel efficiency of 99.97%. Because combustion products enter the heated airstream, adequate ventilation is essential. The heater must not be used to heat human living quarters or in unventilated areas. Always follow the manufacturer's fuel specifications, operating instructions, and applicable safety requirements.
The L.B. White Tradesman® K210 provides a rated heated-air output of 650 CFM. Its integrated fan circulates heated air toward the intended work area, supporting supplemental heating in suitable construction and industrial environments. This forced-air configuration helps distribute warmth beyond the immediate heater outlet. Keep the air inlet and discharge openings unobstructed during operation and maintain the clearances specified in the manufacturer's instructions. Do not connect ductwork unless the manufacturer expressly approves the configuration for this model.
The L.B. White Tradesman® K210 features a portable construction with an integrated 13-gallon fuel tank, wheels, and handles. Manufacturer-published dimensions are approximately 41.8 inches long, 23.1 inches wide, and 26.1 inches high, with a shipping weight of approximately 73.2 lb. Its self-contained fuel supply supports deployment without a separate external tank, while the wheels and handles facilitate transportation between suitable work areas. Position the heater on a stable, level surface and maintain the required clearances from combustible materials. Fuel handling, electrical connection, and operation must follow the manufacturer's instructions and applicable local codes.
The L.B. White Tradesman® K210 operates on kerosene and is also specified for No. 1 and No. 2 diesel fuel and No. 1 fuel oil. Its onboard fuel tank has a capacity of 13 gallons, with maximum fuel consumption of approximately 1.6 gallons per hour. The manufacturer lists a maximum operating time of approximately 8 hours per full tank under specified operating conditions. Actual runtime varies with operating conditions and fuel availability. The fuel pump has a rated pressure of 8.5 PSI. The heater requires a 120 V, 60 Hz electrical supply for fan and ignition operation, with a published continuous operating current of 3.7 A and a motor rating of 1/3 horsepower. Verify the exact electrical requirements against the current owner's manual and unit nameplate before operation.
The L.B. White Tradesman® K210 incorporates a comfort-control thermostat, electronic spark ignition, and onboard fuel and pump-pressure gauges. The thermostat helps regulate heating operation according to the selected temperature, while the gauges support fuel monitoring and maintenance. The manufacturer also identifies an onboard air diagnostic system for troubleshooting and a digital space-temperature display in its Tradesman K product literature. Electrical specifications include a 120 V, 60 Hz supply and a continuous operating current of 3.7 A. Confirm the exact voltage, plug configuration, grounding, circuit capacity, and power connection requirements against the current owner's manual and heater nameplate before operation. Follow the manufacturer's startup and shutdown procedures.
The L.B. White Tradesman® K210 is designed for portable supplemental heating in suitable construction, industrial, and agricultural environments. Its 210,000 BTU/h heating capacity, 650 CFM heated-air output, and integrated fuel tank support temporary heating where directional warmth and portable deployment are required. The manufacturer identifies the Tradesman K series for construction and industrial worksites and certain agricultural applications. Because the heater is direct-fired, the application must meet the manufacturer's ventilation requirements, fuel-burning equipment regulations, and site safety procedures. Confirm suitability for the intended environment before operation.
The L.B. White Tradesman® K210 features integrated wheels and handles to facilitate movement and repositioning. Its approximate dimensions of 41.8 inches long, 23.1 inches wide, and 26.1 inches high provide a portable format for suitable temporary-heating locations. The integrated 13-gallon fuel tank reduces the need to transport a separate tank with the heater. Position the unit securely, maintain all required clearances, and follow the manufacturer's instructions when moving, refueling, or preparing the heater for storage. Disconnect electrical power and allow the heater to cool as directed before handling or servicing.
The L.B. White Tradesman® K210 incorporates dual-prong electronic spark ignition, a comfort-control thermostat, fuel and pump-pressure gauges, and a threaded drain plug. The manufacturer also identifies an onboard air diagnostic system to support troubleshooting. The Tradesman K series is CSA certified for the United States and Canada according to L.B. White product literature. Inspect the heater, electrical cord, fuel tank, fittings, and fuel system before operation. Use only approved fuels, check fuel connections for leaks using an appropriate procedure, and maintain adequate ventilation and specified clearances from combustible materials. Keep air intake and discharge openings unobstructed and never bypass safety devices. Follow the owner's manual for cleaning, draining, servicing, and storage, and have repairs performed by appropriately qualified personnel.
Warranty coverage for the L.B. White Tradesman® K210 should be confirmed directly with L.B. White or an authorized dealer before purchase. Refer to the applicable written manufacturer warranty for coverage duration, exclusions, registration requirements, and installation, operation, or maintenance conditions that apply to this model.
Experience dependable supplemental heating with the L.B. White Tradesman® K210 Portable Forced-Air Kerosene Heater. Combining 210,000 BTU/h heating capacity with 650 CFM heated-air output, an integrated 13-gallon fuel tank, electronic spark ignition, comfort-control thermostat, and onboard fuel and pressure gauges, this portable heater provides directional warmth for suitable construction, industrial, and agricultural applications. Its self-contained fuel supply, integrated wheels and handles, and service-oriented design support flexible deployment wherever direct-fired heating is appropriate and the required ventilation, fuel supply, and electrical connection are available.