Your cookie preferences
We use cookies to remember your preferences and understand how shoppers use our site, helping us improve your shopping experience.
Read our privacy policyThe L.B. White Volt® 18-3 is a 19 kW portable electric forced-air heater designed to provide supplemental heating, drying, and air circulation for construction sites, workshops, and industrial work areas. Delivering up to 65,000 BTU/h of heating output, with selectable 19 kW and 13 kW heating settings, this electric heating system combines stainless steel-jacketed heating elements, an industrial-grade fan, and an integrated ambient thermostat for convenient temperature management. Its powder-coated steel housing, sealed motor, and combustion-free operation provide heat without fuel storage, combustion exhaust, or fuel odors. With a ventilation-only mode and a portable design, the Volt 18-3 provides flexible heating for demanding work environments where a compatible 240 V three-phase electrical supply is available.
The L.B. White Volt® 18-3 delivers up to 65,000 BTU/h of heating output at 19 kW, with a reduced heating setting of 13 kW producing approximately 45,000 BTU/h. A ventilation-only setting circulates air without activating the heating elements. This three-position operating configuration allows users to select full heat, reduced heat, or air circulation according to the application. Its electric resistance heating system provides supplemental warmth without combustion-based fuel delivery. Actual heating performance and coverage depend on ambient temperature, insulation, enclosure size, air infiltration, and other site conditions.
The L.B. White Volt® 18-3 uses electric resistance heating elements housed within the heater's inner barrel. Stainless steel-jacketed heating coils transfer heat to air circulated by the integrated motor-driven fan. The combustion-free design eliminates the need for propane, kerosene, diesel fuel, and other combustion fuels, preventing combustion exhaust from the heating process. This technology is suitable for supplemental heating and drying applications where an appropriately rated electrical supply is available. Although combustion ventilation is not required, the heater must have unobstructed airflow and adequate clearance from combustible materials.
The L.B. White Volt® 18-3 offers selectable blower output of 590 or 1,000 cubic feet per minute (CFM), according to manufacturer specifications. Its integrated fan circulates air through the heating elements and distributes warm air into the surrounding work area. The available airflow settings support different air-distribution requirements for temporary heating, drying, and ventilation. Keep the air intake and discharge openings unobstructed during operation, and maintain the clearances specified in the manufacturer's instructions. Do not connect ductwork unless the manufacturer expressly approves the configuration for this model.
The L.B. White Volt® 18-3 features a portable, self-contained design for temporary heating applications. Manufacturer-published dimensions are approximately 32 inches long, 14 inches wide, and 20 inches high. The unit weighs approximately 62 lb, with a shipping weight of approximately 65 lb. Its compact steel housing supports placement in suitable work areas without requiring permanent HVAC installation or a separate fuel supply. Position the heater on a stable, level surface, maintain the specified clearances, and provide the required electrical connection. Because this model requires a three-phase supply and does not include a factory-installed power cord or plug, the electrical installation must be compatible with the unit's rated requirements and completed in accordance with applicable electrical codes.
The L.B. White Volt® 18-3 operates on a 240 V, 60 Hz, three-phase electrical supply. Manufacturer specifications list a current draw of approximately 81 A at the 19 kW setting and 54 A at the 13 kW setting. The heater is supplied without a factory-installed power cord or plug. L.B. White specifies a maximum cable length of 50 feet using 2 AWG, three-conductor SOOW cable for the listed configuration. Verify conductor sizing, grounding, overcurrent protection, disconnect requirements, and the permitted cable configuration against the current owner's manual, unit nameplate, and applicable electrical codes before installation. Use a properly rated supply capable of supporting the selected heating output.
The L.B. White Volt® 18-3 incorporates an integrated ambient thermostat with a published temperature range of 32°F to 100°F. Its three-position main switch allows selection of ventilation-only operation, reduced heating at 13 kW, or full heating at 19 kW. The thermostat regulates heating operation according to ambient temperature, while thermal protection helps prevent continued operation under excessive-temperature conditions. Electrical requirements are 240 V, 60 Hz, three-phase power, with a rated current draw of 81 A at 19 kW and 54 A at 13 kW. The unit is supplied without a power cord or plug. Electrical connection and circuit protection must be designed and installed by qualified personnel in accordance with the manufacturer's instructions and applicable codes.
The L.B. White Volt® 18-3 is designed for supplemental heating, drying, and air circulation in suitable commercial, construction, and industrial environments. Its maximum heating output of 65,000 BTU/h, selectable heat settings, and adjustable blower output support applications where electric heat is preferred over fuel-fired equipment. Combustion-free operation eliminates combustion exhaust from the heating process and avoids onsite fuel storage. The heater is suitable for work areas where the required three-phase electrical infrastructure is available and the application meets the manufacturer's operating and clearance requirements. Confirm the required heating capacity and electrical supply before selecting the unit for a particular space.
The L.B. White Volt® 18-3 measures approximately 32 inches long, 14 inches wide, and 20 inches high, with a unit weight of approximately 62 lb. Its compact construction allows the heater to be repositioned between suitable work areas when heating requirements change. The manufacturer does not list integrated wheels as a standard feature for this model. Position the heater on a stable, level surface and route electrical connections safely away from hot surfaces and pedestrian or vehicle traffic. Disconnect the power supply and allow the heater to cool before moving, cleaning, or storing the unit.
The L.B. White Volt® 18-3 incorporates overheat protection and an integrated ambient thermostat. Its construction includes stainless steel-jacketed heating coils, a powder-coated steel housing, and a high-quality sealed motor. L.B. White product literature identifies the Volt 18-3 as UL approved. Inspect the heater, electrical connections, housing, fan, and air openings before use. Keep the air intake and discharge unobstructed, maintain the specified clearances from combustible materials, and prevent combustible particles or debris from entering the heater. Dust accumulation can create a fire hazard when exposed to hot heating elements. Before cleaning or servicing, disconnect the electrical supply and allow the heater to cool. Follow the current owner's manual for inspection and maintenance, and have electrical repairs performed by appropriately qualified personnel. Never bypass safety devices or operate the heater with damaged components.
Warranty coverage for the L.B. White Volt® 18-3 should be confirmed directly with L.B. White or an authorized dealer before purchase. Refer to the applicable written manufacturer warranty for coverage duration, exclusions, registration requirements, and any installation, operation, or maintenance conditions that apply to this model. Warranty eligibility may depend on compliance with the manufacturer's instructions and electrical installation requirements.
Experience flexible supplemental heating with the L.B. White Volt® 18-3 Electric Forced-Air Heater. Combining up to 65,000 BTU/h of heating output with selectable 19 kW and 13 kW settings, 590 or 1,000 CFM blower output, an integrated ambient thermostat, and overheat protection, this portable heater provides combustion-free warmth for suitable construction, commercial, and industrial applications. Its durable powder-coated steel housing, stainless steel-jacketed heating coils, and ventilation-only mode support flexible deployment for temporary heating, drying, and air circulation wherever a compatible 240 V three-phase electrical supply is available.