Product Features
  • Ultra-high capacity 60,000 BTU portable heat pump for demanding applications
  • Operates on 480V, 3-phase power for industrial-grade performance
  • Uses R410A refrigerant for efficient and reliable temperature control
  • Heavy-duty portable design with casters for flexible job site placement

Three-Stage 136,500 BTU Portable Electric Heater for Construction & Industrial Applications with Adjustable Heating Output

The L.B. White VOLT® 40 is a 40 kW portable electric forced-air heater designed to provide high-output supplemental heating, drying, and air circulation for construction sites, industrial facilities, workshops, and other suitable work areas. Delivering up to 136,500 BTU/h of heating output, with selectable 32 kW and 16 kW settings for approximately 102,400 BTU/h and 51,200 BTU/h, respectively, this electric heating system combines stainless steel-jacketed heating elements, an industrial-grade fan, and an integrated ambient thermostat. Its combustion-free operation eliminates fuel storage and combustion exhaust from the heating process, while its powder-coated steel housing, sealed motor, and integrated wheels support demanding job-site use. Designed for a 480 V, three-phase electrical supply, the VOLT 40 provides adjustable heating output for applications requiring powerful, portable electric heat.

Key Benefits

  • Up to 136,500 BTU/h Heating Capacity – Delivers high-output supplemental heat for suitable commercial, construction, and industrial applications.
  • Three-Stage Heating Control – Provides 40 kW, 32 kW, and 16 kW settings to accommodate changing heating requirements.
  • Combustion-Free Electric Heating – Produces heat without burning fuel, eliminating combustion exhaust and fuel-related odors.
  • 1,765 CFM Airflow – Circulates heated air throughout the intended work area to support supplemental heating and drying.
  • Integrated Ambient Thermostat – Provides temperature control across a published range of 32°F to 100°F.
  • Durable Industrial Construction – Features stainless steel-jacketed heating coils, powder-coated steel housing, and a sealed motor.
  • Overheat Protection – Incorporates thermal protection designed to interrupt operation if excessive temperatures occur.
  • Integrated Wheels – Support movement and positioning between suitable work areas.
  • UL-Approved Design – The manufacturer's published VOLT 40 specifications identify the model as UL approved.

136,500 BTU/h Three-Stage Electric Heating Performance

The L.B. White VOLT® 40 delivers up to 136,500 BTU/h of heating output at 40 kW. Its three selectable heating settings provide 32 kW of intermediate output, equivalent to approximately 102,400 BTU/h, and 16 kW of reduced output, equivalent to approximately 51,200 BTU/h. This configuration allows operators to adjust the heating level to suit changing site conditions and temperature requirements. The integrated forced-air system provides a rated airflow of 1,765 cubic feet per minute (CFM), helping distribute warmth throughout the intended space. Actual heating coverage depends on ambient temperature, insulation, enclosure size, air infiltration, and other site conditions.

Electric Resistance Heating Technology

The L.B. White VOLT® 40 uses electric resistance heating elements housed within the heater's inner barrel. Stainless steel-jacketed heating coils transfer heat to air circulated by the integrated motor-driven fan. This combustion-free heating process does not require propane, kerosene, diesel, or natural gas, eliminating onsite combustion exhaust and fuel spills associated with fuel-fired heaters. The electric heating design is suitable for supplemental heating and drying where an appropriately rated electrical supply is available. Although combustion ventilation is not required, the heater must have unobstructed airflow, adequate clearance from combustible materials, and operating conditions consistent with the manufacturer's instructions.

1,765 CFM Airflow & Heat Distribution

The L.B. White VOLT® 40 provides a rated blower output of 1,765 CFM. Its integrated industrial-grade fan moves air through the heating elements and distributes warm air into the surrounding work area. This forced-air configuration supports temporary heating and drying applications in construction, commercial, and industrial environments. Keep the air intake and discharge openings unobstructed during operation, and maintain the clearances specified in the owner's manual. The manufacturer does not identify this model as a ductable heater, so ductwork should not be attached unless expressly approved by L.B. White for the specific configuration.

Portable Design & Flexible Installation

The L.B. White VOLT® 40 features a portable, self-contained design for temporary heating applications. Manufacturer-published dimensions are approximately 46 inches long, 20 inches wide, and 25 inches high. The unit weighs approximately 125 lb, with a shipping weight of approximately 130 lb. Integrated wheels help facilitate relocation between suitable work areas. Its compact steel housing supports placement without permanent HVAC installation or a separate fuel supply. The VOLT 40 requires a compatible 480 V, 60 Hz, three-phase electrical supply and must be connected according to the manufacturer's electrical requirements. Position the heater on a stable surface, maintain the specified clearances, and ensure that the electrical connection is properly rated for the selected heating setting.

Electrical Power & Energy Management

The L.B. White VOLT® 40 operates on a 480 V, 60 Hz, three-phase electrical supply and provides three heating levels: 40 kW, 32 kW, and 16 kW. Manufacturer-published current draws are approximately 50 A at 40 kW, 40 A at 32 kW, and 20 A at 16 kW. The heater is supplied without a factory-installed power cord or plug. L.B. White's published specifications list a maximum cable length of 50 feet when using 4 AWG, four-conductor SOOW cable, or up to 100 feet when using 2 AWG, four-conductor SOOW cable for the specified configuration. Verify conductor sizing, grounding, overcurrent protection, disconnect requirements, and cable suitability against the current owner's manual, unit nameplate, and applicable electrical codes before installation. Electrical work must be performed by qualified personnel.

Controls, Temperature Management & Electrical Connection

The L.B. White VOLT® 40 incorporates an integrated ambient thermostat with a published temperature range of 32°F to 100°F (approximately 0°C to 40°C). Its three-stage heating selector allows operation at 16 kW, 32 kW, or 40 kW, providing flexibility to match heat output to the application. The thermostat regulates heating operation according to ambient temperature, while built-in overheat protection helps interrupt operation if excessive temperatures occur. The unit requires 480 V, 60 Hz, three-phase power, with rated current draws of 20 A, 40 A, and 50 A at the low, medium, and high heating settings, respectively. No factory-installed power cord or plug is included. Verify circuit capacity, grounding, connection requirements, and cable specifications against the current manufacturer's documentation and unit nameplate before operation.

Commercial, Construction & Industrial Applications

The L.B. White VOLT® 40 is designed for supplemental heating, drying, and air circulation in suitable construction sites, industrial facilities, workshops, and commercial work areas. Its maximum heating output of 136,500 BTU/h, three selectable heating stages, and 1,765 CFM airflow support applications where high-output electric heat is preferred over fuel-fired equipment. Combustion-free operation eliminates combustion exhaust from the heating process and avoids onsite fuel storage. The portable wheeled design supports temporary deployment where compatible three-phase electrical infrastructure is available. Confirm the heating capacity required for the space and the availability of the specified electrical supply before selecting the unit for a particular application.

Mobility & Deployment

The L.B. White VOLT® 40 measures approximately 46 inches long, 20 inches wide, and 25 inches high. Its integrated wheels help facilitate movement between suitable work areas, while its approximately 125 lb unit weight requires appropriate handling when lifting or transporting the heater. Position the unit on a stable, level surface and maintain all specified clearances. Route electrical connections away from hot surfaces, moving equipment, and pedestrian traffic. Disconnect the electrical supply and allow the heater to cool before moving, cleaning, or storing the unit. Use suitable handling equipment or assistance when needed to prevent injury or damage.

Safety, Service & Maintenance

The L.B. White VOLT® 40 incorporates an integrated ambient thermostat and overheat protection. Its construction includes stainless steel-jacketed heating coils, a powder-coated steel housing, and a sealed motor. L.B. White's published specifications identify the VOLT 40 as UL approved. Inspect the heater, electrical connections, housing, fan, and air openings before use. Keep the air intake and discharge unobstructed, maintain the specified clearances from combustible materials, and prevent combustible particles or debris from entering the heater. Dust accumulation can create a fire hazard when exposed to hot heating elements. The manufacturer's owner documentation specifies minimum clearances of 6 feet at the outlet, 1 foot at the sides, 2 feet at the top, and 2 feet at the rear. Disconnect electrical power and allow the heater to cool before cleaning or servicing. Follow the current owner's manual for inspection and maintenance, and have electrical repairs performed by appropriately qualified personnel. Never bypass safety devices or operate the heater with damaged components.

Warranty

Warranty coverage for the L.B. White VOLT® 40 is subject to the manufacturer's applicable written warranty. Consult L.B. White or an authorized dealer for the current warranty duration, covered components, exclusions, registration requirements, and installation, operation, or maintenance conditions. Warranty eligibility may depend on compliance with the manufacturer's instructions and electrical installation requirements.

Recommended Accessories

  • Heavy-Duty Electrical Cable – Use an appropriately rated four-conductor SOOW cable configured for the 480 V, three-phase supply. Follow the manufacturer's published conductor gauge and maximum cable-length requirements.
  • Electrical Disconnect and Circuit Protection – Provide appropriately rated disconnect equipment and overcurrent protection in accordance with the heater's electrical specifications and applicable electrical codes.
  • Three-Phase Electrical Connection Components – The VOLT 40 is supplied without a factory-installed power cord or plug. Have a qualified electrician select and install compatible connection components for the specified supply.
  • Manufacturer-Approved Replacement Heating Elements – Verify the correct heating-element assembly through official L.B. White parts diagrams and service documentation.
  • Manufacturer-Approved Replacement Thermostat – Confirm compatibility with the VOLT 40 and its temperature-control configuration through official L.B. White parts documentation.
  • Manufacturer-Approved Replacement Fan and Motor Components – Verify compatibility with the VOLT 40 before ordering replacement fan, motor, or thermal protection components.

Reliable High-Output Electric Heating with the L.B. White VOLT® 40

Experience flexible, high-output supplemental heating with the L.B. White VOLT® 40 Electric Forced-Air Heater. Combining up to 136,500 BTU/h of heating output with 1,765 CFM airflow, selectable 40 kW, 32 kW, and 16 kW settings, an integrated ambient thermostat, and overheat protection, this portable heater provides combustion-free warmth for suitable construction, commercial, and industrial applications. Its durable powder-coated steel housing, stainless steel-jacketed heating coils, and integrated wheels support temporary heating and drying wherever a compatible 480 V three-phase electrical supply is available.

Warranty

The LB White Volt 40KW Portable Heater includes a manufacturer’s limited warranty covering defects in materials and workmanship. Warranty coverage typically includes at least one year on parts, with extended coverage for select components depending on distributor terms. It is recommended to review official product documentation for exact warranty details.

More Information
LB White 40kW Electric Forced Air Portable Heater | 480V
FeatureSpec
SKUvolt 40
Weight (in lbs)130
Brand/ManufacturerLB White
Heating BTU136,500
Electrical480 Volts
PhaseThree Phase
Amperage Requirement50A
Operating ModeHeating
Fuel TypeElectric
CertificationUL Listed
ColorWhite
Mounting TypeIndoor/Outdoor
Length32″
Height20″
Width14″
Warranty1 year limited warranty
Resources You will need Adobe Acrobat Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:LB White 40kW Electric Forced Air Portable Heater | 480V
Your Rating
Customer Questions
What is a Portable Heater, and how does it work?
A portable heater is a movable heating unit that provides supplemental or targeted warmth without permanent installation. Depending on the type, it generates heat using electricity, propane, natural gas, or kerosene and distributes it through radiant or forced-air heating.Portable heaters are commonly used in warehouses, workshops, construction sites, garages, and other commercial or residential spaces.
What types of Portable Heaters are available, and which Fuel Type is the best for your heating needs?
Portable heaters are available in electric, propane, natural gas, and kerosene models, each suited to different applications. The best fuel type depends on the heating capacity needed, the available power or fuel supply, ventilation, and whether the space is occupied.Electric: ideal for indoor spaces with adequate electrical capacity.Propane, natural gas, and kerosene: high heat output for construction sites, warehouses, and industrial environments.
What is the difference between direct-fired and indirect-fired Portable Heaters?
Direct-fired portable heaters release heat and combustion byproducts directly into the heated space, so they are best suited to well-ventilated areas. Indirect-fired heaters use a heat exchanger to deliver clean heated air while exhausting combustion gases outside.Indirect-fired models are ideal for enclosed or occupied spaces where cleaner heated air is needed.
What is the difference between radiant and forced-air Portable Heaters?
Radiant portable heaters warm people and objects directly, making them ideal for targeted heating in work areas. Forced-air portable heaters use a fan to circulate warm air throughout a space, making them better suited to larger areas such as warehouses, workshops, and construction sites.The best option depends on whether localized warmth or broader air circulation is needed.
Can Portable Heaters be used both indoors and outdoors?
Yes, portable heaters are available for both indoor and outdoor use, but the appropriate type depends on the fuel source, ventilation, and application.Indoors: electric and approved indirect-fired heaters are commonly used.Outdoors or well-ventilated areas: many direct-fired models are better suited.Always follow the manufacturer's safety and ventilation requirements.
Do Portable Heaters require ventilation?
Ventilation requirements for portable heaters depend on the fuel type and heating design. Direct-fired heaters require adequate ventilation because they release combustion byproducts into the heated space, while indirect-fired models exhaust those gases outdoors.Electric heaters do not produce combustion gases and generally do not require combustion ventilation.
How long will Portable Heaters run on a full fuel tank?
Runtime on a full tank depends on tank capacity, fuel type, heat output, and fuel consumption rate. Larger tanks generally provide longer operation, while higher BTU settings use fuel more quickly.As a rough estimate, runtime in hours = tank size in gallons × fuel BTU per gallon ÷ heater BTU per hour. Propane contains about 91,500 BTU per gallon and kerosene about 135,000. Check the manufacturer's specifications for actual runtime at different heat settings.
What safety features should I look for when purchasing a Portable Heater?
Look for overheat protection, automatic shutoff, flame failure protection, and tip-over protection where applicable. Fuel-fired models should also have safety controls that prevent fuel leaks or unsafe operation, along with clear ventilation requirements.Choose a heater designed for the intended environment and follow the manufacturer's safety guidelines.
How often should Portable Heaters be cleaned and maintained?
Inspect a portable heater before each use and clean it regularly to remove dust, debris, and buildup that can affect performance. Check the fuel lines, filters, burners, electrical connections, and safety controls according to the manufacturer's maintenance schedule.Regular maintenance ensures safe operation, reliable heating, and longer equipment life.
What is the difference between a Portable Heater and a temporary heating system?
A portable heater is a self-contained unit that provides targeted or supplemental heat, while a temporary heating system typically refers to larger equipment used to heat entire buildings or job sites.Portable heaters: ideal for individual work areas, workshops, and smaller spaces.Temporary heating systems: better suited to large construction projects, warehouses, and industrial facilities that need broader coverage.