Reznor UDXC 45,000 BTU Natural Gas Unit Heater, Propeller Fan, Separated Combustion Convertible - Replaces UDX-45 / UDZ-45

SAVE $594.00
Customer reviews
Rating:
5 out of 5
In Stock - 157 Ready to Ship
Free Shipping
By

Reznor

In stock
Model

UDXC-45

ID

108405

Was $1,805.00 Your Low Price Special Price $1,211.00
 
Product Features
  • 45,000 BTU heating capacity with TCORE2 titanium stabilized aluminized steel heat exchanger
  • Vibration isolated propeller fan designed for low noise operation
  • Standard power vent setup can be converted to separated combustion all in one unit
  • Certified for Residential Garages & Workshops, Commercial, and Industrial applications

Introducing the new Reznor UDXC Universal, Gas-Fired Unit Heater. The Reznor model UDXC gas-fired unit heater is designed to provide safety, comfort, and efficiency to industrial, commercial, and residential buildings. The Reznor UDXC boasts a TCORE2 heat exchanger, featuring titanium-stabilized aluminized steel for long-lasting performance and efficient heating.


Included

  • Reznor UDXC 45,000 BTU Low Static Axial Fan Convertible Gas-Fired Unit Heater; Model UDXC-45

Built to last and look great. The UDXC also features a durable, two-tone, scratch-resistant paint finish. Clean rounded corners and edges and hidden fasteners enhance its modern design, making it ideal for industrial or residential use.

Standard Features

  • 45,000 BTU
  • Uses Axial Propeller Fan
  • 83% Thermal Efficiency
  • Field convertible to separated combustion
  • Sealed control compartment houses all electrical components
  • TCORE2 titanium stabilized aluminized steel heat exchanger
  • Vibration/noise isolated fan and venter motors
  • Certified for commercial/industrial heating applications
  • Approved use in residential garages and workshops

Product Note

Replaces UDX-45 / UDZ-45 / UDAP-45 / UDAS-45

More Information
Reznor UDXC 45,000 BTU Natural Gas Unit Heater, Propeller Fan, Separated Combustion Convertible - Replaces UDX-45 / UDZ-45
FeatureSpec
SKUUDXC-45
Weight (in lbs)62
Brand/ManufacturerReznor
ReplacesUDX-45
UPC663132524846
Additional InformationAir Throw: 40 Feet
Furnace Efficiency / AFUE 80-85%
Heating BTU45,000 BTU
Maximum CFM629
Decibel Level (dBA)40
Flue Location4"
Watt155
Efficiency83%
Electrical115 Volt 1 Phase 60 Hertz
PhaseSingle Phase
Amperage Requirement2.4 Amps
Operating ModeHeating
Connection1/2" NG/LP Connection to Gas Valve
Fuel TypeNatural Gas
Height13 3/4"
Width27"
Depth29 3/4"
Warranty9 Year Heat Exchanger, Burner, and Flue Collection Box Assembly; 4 Year All Electrical and Mechanical Components
Resources You will need Adobe Acrobat Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING

Customers Say

Across multiple BTU sizes (45,000 to 150,000 BTU), owners report fast, quiet heating in spaces ranging from a 950 sq ft garage to a 60x40x16 shop and even a 35,000 cubic foot building, with examples including raising temperatures from 35°F to 70°F in 15–20 minutes and maintaining 60°F in -11°F conditions. Installation is frequently described as straightforward—sometimes taking about four hours or reusing existing mounts—with occasional issues such as an incorrect conversion kit or poor delivery handling, but customer service responded promptly to resolve them.

AI Generated from the text of customer reviews

Top reviews
  1. Fast delivery, great price, excellent packaging with zero damage. Easy to install.
    Quality
    100%
    Service
    100%
    Price
    100%
    Ordered to replace an old UDAP 45. Basically the same but taller. Fit fine as a hanging unit in the garage. Quieter and warmer output than the old one. Pretty much just unhooked the old one, unmounted it and mounted the new one with the same bolts, reattached connections with a slight modification to the venting. Free shipping and it still got here in less than a week. Overall, great experience with HVACDirect and the price was the lowest I could find.

    Review by

    Posted on

Customer Questions
Can this heater be used to heat a home?
These heaters can be used in a garage, but they are not approved for use in indoor living spaces. If you have any further questions, please feel free to give us a call! Thanks.
If the green light is green flashing, what does that mean?
There are a variety of things that this could indicate. Refer to Table 26 on page 59 of the Reznor UDXC Installation and Maintenance Manual. If you have any further questions, please feel free to give us a call! Thanks.
What type of venting do these unit heaters require? B-vent or PVC?
These units require Category I (B-vent) for vertical venting through the roof, or Category III for venting horizontally through side walls. The exhaust on these units exceeds a temperature that would allow for PVC Venting. If you have any further questions, please feel free to give us a call. Thanks!
Can I use PVC pipe for the combustion air intake?
Reznor does not approve the use of PVC pipe for combustion air intake. Reznor only approves the use of the concentric venting, which is not compatible with PVC. Attempting to vent non-concentric can lead to pressure imbalances which would cause the pressure switch to intermittently turn the unit off. If you have any further questions, please feel free to give us a call. Thanks!
What is the max length for B-vent to exhaust through the roof?
Please refer to pages 34-35 of the installation manual for vertical venting size constraints. This installation manual is linked on the Product Specifications tab for this unit and listed in the Resources section. If you have any further questions, please feel free to give us a call. Thanks!
Wondering what recommendations for an exhaust fan with my Resor 45,000 separate combustion unit should have for my garage is approximately 24 x 24 double car garage. Only one garage door with one window reznor unit is at the Southeast corner the Garage., Street West is the garage door then straight north is the small win dow
The best recommendation depends on how the garage will be used. If it's primarily for parking and occasional hobbies, an 18" direct-drive shutter exhaust fan is typically a great option. If the garage is used more frequently for activities like welding, painting, or other projects that generate heat or fumes, a 24" direct-drive shutter exhaust fan would generally be the better choice. If you can give us a call to discuss how they use the space and what they're looking to accomplish, we'd be happy to recommend the exact unit that best fits their application.
Did you find what you were looking for?