The Stealth Designer+ Series Multi Zone mini-split systems offer elite performance across a range of air handler types suitable for any application. In addition to standard wall mounted air handlers, ceiling cassette, concealed ducted and floor mounted heat console type air handlers are available.
With the Designer series, different air handler types can be mixed and matched to create a custom system perfectly suited to any home or space.
Additional features include continuous heating down to an outside temperature of -31 degrees and I-Feel temp sensing.
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 3/8 inch O.D. flared ends, length 15 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 1/2 inch O.D. flared ends, length 15 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
Ensure a professional and secure installation for your condenser with this comprehensive installation kit. Designed to provide all the essential components needed for a smooth setup, this kit helps protect your system while ensuring proper electrical and refrigerant connections.
Equip your condenser with everything needed for a safe, durable, and professional installation. Order your Condenser Installation Kit today!
E Liteis a plastic pad designed as a mounting base for air conditioning condensers. The rugged design provides uniform and generous ribbing for optimum, self-leveling ground support without inserts. E Lite is injection molded from polypropylene, resulting in a pad that is lightweight, but not too light. A subtle texture prevents unit slide and presents a classic appearance, which is enhanced by rounded edges and a concrete gray color. Each pad is molded with its size in raised letters.
All sales of this product are final and are non-refundable.
Provides even heating and cooling for rooms up to 800 sq ft, this Stealth Designer ceiling cassette uses R410A refrigerant to deliver balanced, all-direction comfort.
Discreet Ceiling Installation
The ceiling cassette design allows the air handler to be installed flush with the ceiling, leaving only a decorative grille visible. This ensures efficient climate control while maintaining a clean, modern aesthetic in the room.
Even Airflow Distribution
Multi-directional airflow delivers consistent heating and cooling across the room, minimizing hot or cold spots. Ideal for open layouts or rooms with irregular shapes, it provides comfortable temperatures in every corner.
Multi-Zone System Integration
Designed for multi-zone systems, this indoor unit allows independent temperature control of its zone, giving customized comfort and improved energy efficiency when paired with compatible outdoor condensers.
The Stealth Comfort Designer+ ceiling cassette air handler is backed by a manufacturer warranty to ensure long-term performance and reliability. Warranty coverage applies according to manufacturer registration and installation guidelines.
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 3/8 inch O.D. flared ends, length 25 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 1/2 inch O.D. flared ends, length 25 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
This wall mount bracket is perfect for outdoor mini split condensers. The length of the the wall bracket arms are 21" long. The condensing unit is mounted onto the L-shaped brackets and fastened using the bolts and anti-vibration washers provided.
Features:
All sales of this product are final and are non-refundable.
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 3/8 inch O.D. flared ends, length 30 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 1/2 inch O.D. flared ends, length 30 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
This insulated refrigerant line set for mini split systems comes as a pair, including both the liquid line and suction line. It is used to connect the indoor air handler to the outdoor condenser. The line set is 35’ feet long. The liquid line has 1/4 inch outside diameter flared ends. The suction line has 3/8 inch outside diameter flared ends.
Features:
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 1/2 inch O.D. flared ends, length 35 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 3/8 inch O.D. flared ends, length 50 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 1/2 inch O.D. flared ends, length 50 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features: