COMPETITIVE PRICING
We sell products at wholesale pricing. No markups, no hidden fees. Our average customer saves BETWEEN THREE TO SIX THOUSAND DOLLARS
-That's the Direct Advantage!
AHRI Number:10489375
An AirQuest combination system is a great choice to keep your home comfortable all year long. With tons of extra features and a great price, the NXH648GKA is a perfect choice for a heat pump.
All AirQuest models come with a 10 year parts warranty and 20 year heat exchanger limited warranty. Not intended for use in mobile homes.
This 208/230 volt heater coil can be added to a ACiQ air handlers to provide winter-time heating capabilities. Produces 34,000 BTUs of heat. Circuit breakers are included with this heater coil.
This 208/230 volt heater coil can be added to a ACiQ air handlers to provide winter-time heating capabilities. Produces 51,000 BTUs of heat.
This 208/230 volt heater coil can be added to a ACiQ air handlers to provide winter-time heating capabilities. Produces 68,000 BTUs of heat.
Line sets are the copper lines which connect an outdoor condensing unit/heat pump to an inside air handler or evaporator coil. Line sets are available in different lengths and diameters to fit most applications.
With its efficient ECM blower motor and factory-installed TXV kit, the ACiQ FEM4X4800BL is a convenient and efficient air handler to provide comfort to your home. If you want superior quality and enhanced comfort, look no further than this model.
The ACiQ FEM4X4800BL air handler is rated for an output of 4 tons. In many cases, this air handler will be larger in tonnage than the condenser it is paired with to maintain the unit's overall efficiency. Please note that for this unit to provide cooling, an outdoor condenser is required for it to function. The unit can support electric heating as a straight electric furnace or as a backup for a heat pump, offered at an additional cost to be field installed.
ACiQ offers a 10 year no hassle replacement warranty, as well as a 10 year parts warranty on this unit. For these warranties to be upheld, the unit must be installed following your state and local codes, a new and certified coil must be installed at the same time, and the entire system must be registered online through the manufacturer. After your purchase, a representative will reach out to you to retrieve installation information so we can register the product for you.
To make a more versatile unit, ACiQ designed the FEM4X4800BL to easily be installed in an upflow, downflow, or horizontal position. A TXV kit is already installed on the unit so your installer does not have to install one, decreasing installation costs. For durability, the FEM4X4800BL air handler is designed with an extremely strong, one-piece outer casing to protect the unit, and the coil is designed with corrosion-resistant aluminum.
The FEM4X4800BL air handler has an efficient ECM blower motor, providing a more stable temperature in your home, making you more comfortable. The control board will automatically communicate with your thermostat to adjust the output of the blower to suit your needs. With this intelligent comfort and efficiency, the FEM4X4800BL meets ACiQ's superior standards.
This 208/230 volt heater coil can be added to a ACiQ air handlers to provide winter-time heating capabilities. Produces 17,000 BTUs of heat.
Line sets are the copper lines which connect an outdoor condensing unit/heat pump to an inside air handler or evaporator coil. Line sets are available in different lengths and diameters to fit most applications.
This 208/230 volt heater coil can be added to a ACiQ air handlers to provide winter-time heating capabilities. Produces 23,800 BTUs of heat.
10 Kilowatt 34,000 BTU ACiQ Heater Coil | |
---|---|
SKU | EHK10AKB |
Weight (in lbs) | 9.000000 |
Brand/Manufacturer | ACiQ |
Equivalent | Carrier Equivalent: KFCEH2601C10 Tempstar Equivalent: EHK10AKB Bryant Equivalent: KFCEH2601C10 |
Heating BTU | 34,000 |
Electric Heat | 10 Kilowatts |
Electrical | 208 / 230 / 240 Volts / 1 Phase |
Phase | Single Phase |
Min. Breaker Size | 60 Amps |
Resources | You will need Adobe® Acrobat® Reader to view PDF documents. |
Safety Information | PROPOSITION 65 WARNING |
15 Kilowatt 51,000 BTU ACiQ Heater Coil | |
SKU | EHK15AKB |
Weight (in lbs) | 9.000000 |
Brand/Manufacturer | ACiQ |
Equivalent | Carrier Equivalent: KFCEH3101C15 |
Heating BTU | 51,000 |
Electric Heat | 15 Kilowatts |
Electrical | 208 / 230 / 240 Volts / 1 Phase |
Phase | Single Phase |
Min. Breaker Size | Circuit 1: 60 amps / Circuit 2: 30 amps / Single Wire Kit: 80 Amps |
Resources | You will need Adobe® Acrobat® Reader to view PDF documents. |
Safety Information | PROPOSITION 65 WARNING |
20 Kilowatt 68,000 BTU ACiQ Heater Coil | |
SKU | EHK20AKB |
Weight (in lbs) | 9.000000 |
Brand/Manufacturer | ACiQ |
Equivalent | Carrier Equivalent: KFCEH3301C20 |
Heating BTU | 68,000 |
Electric Heat | 20 Kilowatts |
Electrical | 208 / 230 / 240 Volts / 1 Phase |
Phase | Single Phase |
Min. Breaker Size | Circuit 1: 60 amps / Circuit 2: 60 amps / Single Wire Kit: 120 Amps |
Resources | You will need Adobe® Acrobat® Reader to view PDF documents. |
Safety Information | PROPOSITION 65 WARNING |
30 Feet of 3/8" LL x 7/8" SL x 3/8" Insulated Line Set | |
SKU | LS38783830 |
Weight (in lbs) | 30.000000 |
Brand/Manufacturer | Online Supply |
Liquid Line | 3/8" |
Suction Line | 7/8" |
Suction Line Insulation Thickness | 3/8" |
Length | 30 feet |
Safety Information | PROPOSITION 65 WARNING |
4 Ton 16 SEER ACiQ Heat Pump Condenser | |
SKU | NXH648GKA |
Weight (in lbs) | 238.000000 |
Brand/Manufacturer | ACiQ |
Cooling BTU | 48,000 |
Heating BTU | 48,000 |
Maximum CFM | 4,046 |
Decibel Level (dBA) | 73 |
Motor RPM | 810 |
Horsepower | .25 HP |
Refrigerant | R410A |
SEER1 (Efficiency) | 16 |
Condenser Stages | Single Stage |
Compressor Type | Scroll |
Liquid Valve Size | 3/8" |
Suction Valve Size | 7/8" |
Electrical | 208 / 230 V. 1 Phase 60 Hz |
Phase | Single Phase |
Max Breaker Size | 45 Amps |
Min. Breaker Size | 31.8 Amps |
Tonnage | 4 Ton |
Height | 32 1/16" |
Width | 35" |
Depth | 35" |
Warranty | 10 Years with Online Registration |
Resources | You will need Adobe® Acrobat® Reader to view PDF documents. |
Safety Information | PROPOSITION 65 WARNING |
4 Ton Multi-Positional ACiQ Air Handler | |
SKU | FEM4X4800BL |
Weight (in lbs) | 157.000000 |
Brand/Manufacturer | ACiQ |
Equivalent | Carrier Equivalent: FB4CNP048L00 Tempstar Equivalent: FEM4X4800BL Bryant Equivalent: FB4CNP048L00 |
Blower Motor | ECM 5-Speed Motor |
Maximum CFM | 1600 |
Motor RPM | 570-1400 |
Horsepower | .75 HP |
Horsepower | .75 HP |
Electric Backup Heat Capabilities (Optional) | 5 Kilowatts, 8 Kilowatts, 10 Kilowatts, 15 Kilowatts, 20 Kilowatts, 25 Kilowatts |
Configuration | Upflow, Downflow, Horizontal |
Refrigerant | R410A |
Filter Size | 19 7/8" x 21 1/2" |
EER | 11.5-12 |
Liquid Line | 3/8" |
Suction Line | 7/8" |
Electrical | 208/230v 1 Phase 60 Hz |
Phase | Single Phase |
Max Breaker Size | 15 Amps |
Tonnage | 4 Ton |
Connection | Sweat |
Certification | UL Listed |
Height | 49 5/8" |
Width | 21 1/8" |
Depth | 22 1/16" |
Warranty | 1 Year No Hassle Replacement and 10 Year Parts with Registration |
Resources | You will need Adobe® Acrobat® Reader to view PDF documents. |
Safety Information | PROPOSITION 65 WARNING |
5 Kilowatt 17,000 BTU ACiQ Heater Coil | |
SKU | EHK05AKB |
Weight (in lbs) | 9.000000 |
Brand/Manufacturer | ACiQ |
Equivalent | Carrier Equivalent: KFCEH2401C05 Tempstar Equivalent: EHK05AKB Bryant Equivalent: KFCEH2401C05 |
Heating BTU | 17,000 |
Electric Heat | 5 Kilowatts |
Electrical | 208 / 230 / 240 Volts / Phase 1 |
Phase | Single Phase |
Min. Breaker Size | 30 Amps |
Resources | You will need Adobe® Acrobat® Reader to view PDF documents. |
Safety Information | PROPOSITION 65 WARNING |
50 Feet of 3/8" LL x 7/8" SL x 3/8" Insulated Line Set | |
SKU | LS38783850 |
Weight (in lbs) | 30.000000 |
Brand/Manufacturer | Online Supply |
Liquid Line | 3/8" |
Suction Line | 7/8" |
Suction Line Insulation Thickness | 3/4" |
Length | 50 feet |
Safety Information | PROPOSITION 65 WARNING |
7 Kilowatt 23,800 BTU ACiQ Heater Coil | |
SKU | EHK07AKB |
Weight (in lbs) | 9.000000 |
Brand/Manufacturer | ACiQ |
Equivalent | Carrier Equivalent: KFCEH2501C08 Tempstar Equivalent: EHK07AKB Bryant Equivalent: KFCEH2501C08 |
Heating BTU | 23,800 |
Electric Heat | 7 Kilowatts |
Electrical | 208 / 230 / 240 Volts / Phase 1 |
Phase | Single Phase |
Min. Breaker Size | 45 Amps |
Resources | You will need Adobe® Acrobat® Reader to view PDF documents. |