Learning System - The ACiQ-48-HP32 / ACiQ-48-AH32 system features advanced sensors that monitor indoor and outdoor air temperature, system performance, duct pressure, and refrigerant temperature. During initial startup, it enters a learning mode, maintaining airflow across the sensors and storing critical data to optimize future startups and run cycles for maximum efficiency.

Size for Heat - Thanks to its self-adjusting inverter design, the ACiQ-48-HP32 / ACiQ-48-AH32 can be sized based on heat demand. Unlike traditional heat pumps that can cause excessive humidity in summer when sized for heating, this system intelligently adjusts to function like a smaller unit, delivering optimal cooling and dehumidification.

QUICK FACTS

  • 34,000 BTU to 52,000 BTU variable output based on demand
  • Inverter heat pump system designed for ducted applications
  • Reliable cooling performance from 5°F to 129°F outdoor temperatures
  • Efficient heating operation from -22°F to 75°F outdoor temperatures
  • Gold Fin condenser coil coating for enhanced durability
  • Quiet operation even during demanding workloads

Performance

With a 19 SEER2 efficiency rating, the variable output ACiQ-48-HP32 / ACiQ-48-AH32 system ensures consistent comfort across a range of conditions. Use our size calculator to determine the appropriate capacity for your home. This system delivers flexible cooling performance, operating anywhere between 34,000 BTU and 54,000 BTU without short cycling.

More Information
ACiQ 4 Ton 19 SEER2 High Efficiency Central Heat Pump | Inverter | Extreme Series | R32
SKUACIQ-48-HP32
Weight263.500000
ManufacturerACiQ
Product FeaturesInverter, Low Ambient Heating, Two Stage Condenser, Variable Speed Condenser
HSPF210
Cooling BTU48000 BTU
Heating BTU48000 BTU
Maximum CFM3176
Decibel Level (dBA)71 (Max)
Electric HeatHeat Pump
RefrigerantR32
SEER219
Condenser StagesVariable Speed
Compressor TypeRotary
Liquid Line3/8"
Suction Line3/4"
Electrical208/230V 1 Phase 60 Hz
Tonnage3 Ton
BTU/Tonnage36,000 BTU/3 Ton
Min/Max Outdoor Temp for Heating-22 ~75
Min/Max Outdoor Temp for Cooling 5~129
Zone CompatibilitySingle Zone
Height49.6"
Width35.5"
Depth13.4"
Warranty12 year compressor, 7 year parts with online registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
4 Ton ACiQ Central Air Handler | R32
SKUACIQ-48-AH32
Weight199.500000
AHRI Certificate Number215387240
ManufacturerACiQ
HSPF210.0
Cooling BTU48000 BTU
Heating BTU48000 BTU
Maximum CFM1200
Decibel Level (dBA)62 (Max)
Electric HeatHeat Pump
RefrigerantR32
Liquid Line3/8"
Suction Line3/4"
Electrical208/230V 1 Phase 60 Hz
Tonnage Bundle4 Ton
BTU/Tonnage48,000 BTU/4 Ton
Mini Split TypeMulti-Positional
Zone CompatibilitySingle Zone
Height52"
Width24.8"
Depth21.25"
Warranty12 year compressor, 7 year parts with online registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
You're reviewing:ACiQ 4 Ton 19 SEER2 High Efficiency Central Heat Pump System | Inverter | Extreme Series | R32
Your Rating
Customer Questions
On the air handler - will an auxiliary heat kit be needed?
We recommend getting a heat kit installed if you live in an area where temperatures are frequently below zero during winter months. While the heat pump condenser can continue to operate at these temperatures, having a heat kit installed as a backup in case the temperatures go even lower would be a very safe choice. If you have any further questions, please call us and we will be happy to assist you.
a 10kw heating element says it needs a 60amp breaker to operate- is this a sperate circuit from the airhandler
Yes, the 10kW heating element needs a separate 60-amp breaker and circuit from the air handler for safety and proper load distribution. Always follow manufacturer specs and local codes.
Did you find what you were looking for?