Daikin 15 Ton 14.2 IEER Commercial Packaged Air Conditioner | 208/230V 3 Phase - R32 - Single Stage

Daikin 15 Ton 14.2 IEER Commercial Packaged Air Conditioner | 208/230V 3 Phase - R32 - Single Stage
By

Daikin

In stock
Model

DSC1803D000001S

ID

190754

Was $23,115.00 Your Low Price Special Price $17,500.00
ONLY 4 LEFT!
 
Product Features
  • Designed for Easy Retrofit Installs
  • Custom Roof Curbs designed to fit your current adapter!
  • Precharged with R32 Refrigerant
  • Single Stage Condenser
  • 208/230V 3 Phase
  • Up to a 5 Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

Efficient 15-Ton Air Conditioner Rooftop Unit for Light Commercial Applications with Two-Stage Cooling

The Daikin DSC1803D000001S is a 15-ton commercial packaged air conditioner designed to provide reliable, efficient cooling for light commercial applications. Combining 172,000 BTU/h of cooling capacity with two individually circuited scroll compressors, a direct-drive supply fan, and R-32 refrigerant, this all-in-one rooftop system helps deliver dependable cooling and efficient part-load operation while simplifying installation and preserving valuable indoor space.

Key Benefits

  • 15.0 IEER / 11.2 EER Efficiency – Provides efficient cooling performance across full-load and part-load operating conditions.
  • 172,000 BTU/h Cooling Capacity – Provides substantial cooling capacity for light commercial buildings and applications.
  • Two Individually Circuited Scroll Compressors – Provides two-stage cooling operation to help match cooling output to changing load requirements.
  • Direct-Drive Supply Fan – Provides dependable air movement without belt-driven components, helping simplify service and maintenance.
  • Packaged Rooftop Configuration – Combines major air conditioning components in one outdoor unit to simplify equipment placement and preserve valuable indoor space.
  • Galvanized-Steel Cabinet – Provides durable construction for outdoor rooftop operation.
  • Convertible Airflow Orientation – Supports downflow or horizontal applications for greater installation flexibility.
  • Tool-Less Filter Access – Provides convenient access for routine filter service and maintenance.

Daikin Air Conditioner Commercial Rooftop Units

Discover the advantages of Daikin R-32 Commercial Packaged Air Conditioners, designed to deliver reliable cooling, energy-efficient performance, and lasting durability.

Featured advanced HVAC technology and environmentally conscious R-32 refrigerant, these commercial rooftop units offer a lower-GWP alternative to traditional R-410A systems.

Their all-in-one design and service-friendly components help simplify installation and ongoing maintenance for contractors and building owners.

Whether upgrading existing equipment or planning a new installation, Daikin provides innovative commercial cooling solutions built for dependable performance.

Watch the video to learn more about what makes Daikin a trusted choice for Commercial HVAC.


Two-Stage Scroll Compressor System – Primary Cooling Benefit

The integrated air conditioning system uses two individually circuited scroll compressors to provide 172,000 BTU/h of nominal cooling capacity. The two refrigeration circuits provide staged cooling operation, allowing the system to better match cooling output to changing load requirements. The DSC1803D000001S uses R-32 refrigerant.

172,000 BTU/h Cooling Performance

The DSC1803D000001S provides 172,000 BTU/h of nominal cooling capacity with an 11.2 EER and 15.0 IEER rating. This helps provide dependable commercial cooling performance while supporting efficient operation across full-load and part-load conditions.

Efficient Direct-Drive Operation

With an 11.2 EER and 15.0 IEER rating and a direct-drive indoor fan, this system is designed to provide efficient air movement and reliable cooling performance. The direct-drive configuration eliminates belt-driven components, helping simplify routine service and maintenance.

Packaged Rooftop Installation Design

The packaged rooftop configuration combines the compressors, condenser, evaporator coil, supply fan, controls, and other air distribution components into a single outdoor unit, helping simplify equipment placement and preserve valuable indoor space. The DSC1803D000001S is designed for new construction and retrofit applications and supports flexible downflow or horizontal airflow configurations.

Controls & Comfort

The DSC1803D000001S features a 24-volt electromechanical controls package for straightforward commercial system operation. Two individually circuited scroll compressors provide staged cooling operation, while the direct-drive supply fan provides dependable air distribution. The unit is configured for 208/230-volt, three-phase electrical service.

Commercial Applications

The Daikin DSC1803D000001S is designed for comfort cooling applications in light commercial buildings and other commercial environments requiring packaged rooftop air conditioning. Its 172,000 BTU/h cooling capacity, staged cooling system, direct-drive supply fan, and flexible airflow configuration make it well suited for applications where reliable cooling, efficient part-load operation, and installation flexibility are important.

Service & Maintenance

The DSC1803D000001S is designed for convenient service access and routine maintenance. Its direct-drive indoor fan eliminates belt-driven components, while the packaged configuration keeps the major refrigeration, airflow, and control components together in one outdoor unit. Tool-less filter access helps simplify routine filter maintenance, while accessible service components help support regular equipment inspection and servicing.

Warranty

The Daikin DSC1803D000001S includes a Daikin limited warranty. Complete warranty details are subject to applicable Daikin warranty terms and conditions.

Recommended Accessories

Efficient Commercial Cooling with the Daikin DSC1803D000001S

Experience reliable, efficient commercial cooling with the Daikin DSC1803D000001S. Combining R-32 refrigerant, two individually circuited scroll compressors, 15.0 IEER / 11.2 EER efficiency, direct-drive air distribution, and flexible downflow or horizontal airflow configuration in one packaged rooftop air conditioning system.

Packaged Unit Buyers Guide

  • How packaged units work for residential and commercial use
  • The different types of packaged units
  • Figuring out the right size unit for your needs
  • The importance of a custom curb adapter
  • And much more!
More Information
Daikin 15 Ton 14.2 IEER Commercial Packaged Air Conditioner | 208/230V 3 Phase - R32 - Single Stage
FeatureSpec
SKUDSC1803D000001S
Refrigerant ChargePre-charged
Weight (in lbs)1736
Brand/ManufacturerDaikin
ReplacesDFC1803D000001S
UPC633190263100
Additional InformationUses eight 20" x 20" x 2" filters
Cooling BTU172,000 BTU
Drive TypeDirect
Maximum CFM5000
Decibel Level (dBA)80.4 decibels
Motor RPM300-1600 RPM
HorsepowerIndoor Horsepower: 3.5, Outdoor Horsepower: 1/3
ConfigurationDownflow
RefrigerantR32
EER11
IEER14.2
Condenser StagesSingle Stage
Compressor TypeScroll
Electrical208/230v 3 Phase 60 Hz
PhaseThree Phase
Max Breaker Size100 Amps
Min. Breaker Size84.1 Amps
Tonnage15 Ton
Height51 11/16"
Width113 3/8"
Depth88 1/2"
Warranty20 Years Heat Exchanger, 5 Years Parts with Online Registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Daikin 15 Ton 14.2 IEER Commercial Packaged Air Conditioner | 208/230V 3 Phase - R32 - Single Stage
Your Rating
Customer Questions
What does BTU and Tonnage Mean?
BTU (British Thermal Unit) measures the amount of heating or cooling energy a commercial rooftop packaged unit can produce per hour, while tonnage measures the unit's nominal cooling capacity. One ton of cooling equals 12,000 BTU/h, meaning a 10-ton commercial rooftop unit provides approximately 120,000 BTU/h of cooling capacity. Both measurements help contractors and customers determine the appropriate HVAC system size and output for a building's heating and cooling requirements.
What accessories or additional components are needed to install a Commercial Rooftop Units?
Installing a commercial rooftop unit may require several accessories and additional components depending on the building's existing setup and installation requirements. Common components include a roof curb or curb adapter, ductwork transitions, electrical disconnects, thermostats, economizers, dampers, and supplemental heating kits when applicable. Additional accessories, such as hail guards, smoke detectors, and condensate drain components, may also be recommended based on the application. Always verify equipment compatibility and manufacturer installation requirements before purchasing additional components.
Can I replace my existing Commercial Rooftop Unit without replacing the ductwork?
Yes. In many cases, an existing commercial rooftop unit can be replaced without replacing the current ductwork, provided the duct system is in good condition and compatible with the new equipment. Before installation, an HVAC professional should evaluate the ductwork, airflow requirements, unit capacity, and existing connections to ensure proper system performance. Additional modifications may be necessary if the new unit has different dimensions, airflow configurations, or connection requirements.
How efficient is a Commercial Air Conditioner Packaged Rooftop Unit?
The typical efficiency of a Commercial AC-Only Rooftop Packaged Unit varies by model, size, and manufacturer, with IEER ratings generally ranging from approximately 13 to 20 or higher. Efficiency is measured using EER (Energy Efficiency Ratio) and IEER (Integrated Energy Efficiency Ratio), with higher ratings indicating greater cooling efficiency and potentially lower electricity costs. Actual efficiency ratings should be verified using the manufacturer's specifications for each model.
What is the average life expectancy of a Commercial Air Conditioner Rooftop Packaged unit?
The average life expectancy of a commercial AC rooftop packaged unit is approximately 15–20 years. Actual lifespan depends on factors such as installation quality, operating conditions, usage, and routine preventative maintenance. Regular professional servicing, filter replacements, and keeping coils and components clean can help extend the system's lifespan and maintain reliable performance.
What are the Commercial Rooftop Air Conditioner efficiency ratings and what do they mean?
Commercial rooftop air conditioner efficiency ratings measure how effectively a unit converts electricity into cooling output. Common ratings include SEER2 (Seasonal Energy Efficiency Ratio 2), which measures seasonal cooling efficiency, and EER2 (Energy Efficiency Ratio 2), which measures cooling efficiency under specific operating conditions. Higher efficiency ratings generally indicate lower energy consumption and reduced operating costs. When comparing commercial rooftop AC units, consider both efficiency ratings, cooling capacity, building requirements, and expected usage to determine the best fit for your application.
Does a Commercial Air Conditioner Rooftop Packaged Unit provide heating?
A commercial AC rooftop packaged unit is primarily designed to provide cooling and does not typically include built-in heating capabilities. However, some models offer optional electric heat kits that provide supplemental heating when needed. If both heating and cooling are required, a commercial gas/electric packaged unit or rooftop heat pump may be a better solution.
What is the difference between single-stage, two-stage, and variable-speed Commercial Air Conditioners?
The difference between single-stage, two-stage, and variable-speed commercial air conditioners is how they adjust cooling output to meet a building's temperature demands. Single-stage units operate at one fixed cooling capacity, running at full output whenever cooling is needed. Two-stage units offer high and low cooling settings, allowing them to adjust output based on demand for improved temperature control and efficiency. Variable-speed units can continuously adjust compressor and airflow output to better match changing cooling requirements, providing more consistent temperatures, improved humidity control, and potentially greater energy efficiency.
Did you find what you were looking for?
blockboard tech