Daikin 3 Ton 90,000 BTU 14 SEER2 Commercial Gas Packaged Unit | 208/230V 3 Phase - R32 - Single Stage

Daikin 3 Ton 90,000 BTU 14 SEER2 Commercial Gas Packaged Unit | 208/230V 3 Phase - R32 - Single Stage
By

Daikin

In stock
Model

DSG0363DH00001S

ID

190766

Was $5,980.00 Your Low Price Special Price $5,200.00
ONLY 2 LEFT!
Free Shipping
 
Product Features
  • Designed for Easy Retrofit Installs
  • Custom Roof Curbs designed to fit your current adapter!
  • Precharged with R32 Refrigerant
  • Single Stage Condenser
  • 208/230V 3 Phase
  • Up to 20-Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

Reliable Heating and Cooling Gas/Electric Packaged Rooftop Unit for Light Commercial Applications

The Daikin DSG0363DH00001S is a 3-ton commercial gas/electric packaged rooftop unit designed to provide reliable year-round heating and cooling for light commercial applications. Combining 90,000 BTU/h high-stage gas heating input with 35,000 BTU/h cooling capacity, this all-in-one rooftop system helps deliver dependable comfort while simplifying equipment placement and installation.

Key Benefits

  • 14 SEER2 and 12 EER2 Cooling Efficiency – Provides reliable cooling efficiency to support efficient operation in commercial applications.
  • Two-Stage Gas Heating – Provides 67,500 BTU/h low-stage input and 90,000 BTU/h high-stage input to help match heating output to changing comfort demands.
  • Reliable Cooling – A single-stage scroll compressor and microchannel outdoor coil provide dependable cooling performance.
  • Installation Flexibility – The packaged rooftop design is suitable for both new construction and retrofit projects, and Daikin units are designed as direct replacements for most rooftop units without requiring a curb adapter.
  • Space-Saving Rooftop Design – Combines the gas heating, cooling, and air-moving components in one outdoor cabinet to help preserve valuable indoor space.
  • Durable Cabinet Construction – High-quality galvanized steel with a powder-paint finish provides increased corrosion resistance for outdoor installation.
  • Comfort-Focused Airflow – A direct-drive indoor blower provides airflow for a range of commercial applications while helping simplify airflow control.
  • Service-Friendly Design – A well-organized, weatherproof internal control box and draw-through filter section help simplify commissioning and routine maintenance.

Two-Stage Gas Heating for Reliable Comfort

The integrated two-stage gas heating system provides 67,500 BTU/h of low-stage input and 90,000 BTU/h of high-stage input, with corresponding outputs of 54,000 BTU/h and 72,000 BTU/h. The heating section uses four burners and provides 80% thermal efficiency, helping deliver dependable heating performance while allowing the system to operate at a lower heating stage when full capacity is not required.

35,000 BTU/h Cooling Performance

The single-stage scroll compressor provides 35,000 BTU/h of total cooling capacity. The unit delivers 14 SEER2 and 12 EER2 for 3-ton operation, helping provide dependable cooling performance and efficient operation during warm-weather commercial use.

R-32 Refrigerant and Efficient Operation

The DSG0363DH00001S uses R-32 refrigerant and a microchannel outdoor heat exchanger designed to support efficient heat transfer. The system combines its cooling components with a direct-drive indoor blower and single-stage scroll compressor to provide dependable packaged heating and cooling performance for light commercial applications.

Packaged Rooftop Installation Design

The packaged rooftop configuration combines the gas heating section, cooling system, indoor blower, controls, and filtration into a single outdoor unit, helping simplify equipment placement and preserve valuable indoor space.

Controls & Comfort

The DSG0363DH00001S uses a factory-installed controls system with a well-organized, weatherproof internal control box designed for convenient access. Two-stage gas heating provides low- and high-stage operation, while the multi-speed ECM indoor motor helps provide controlled airflow for dependable commercial comfort.

Commercial Applications

The Daikin DSG0363DH00001S is designed for light commercial rooftop applications where dependable gas heating and electric cooling are required from a single packaged system. Its packaged rooftop configuration, direct-drive supply fan, factory-tested electrical system, and retrofit-friendly design make it well suited for applications such as retail spaces, offices, restaurants, schools, warehouses, and other light commercial buildings.

Service & Maintenance

The DSG0363DH00001S is designed with service accessibility in mind, including a weatherproof internal control box with convenient access and a draw-through filter section. The unit includes high- and low-pressure switches and factory wiring and testing to help support commissioning and start-up. The direct-drive indoor fan also eliminates belt and pulley maintenance associated with belt-driven blower systems.

Warranty

The Daikin DSG0363DH00001S includes a 20-year heat exchanger limited warranty and a 5-year parts limited warranty. Complete warranty terms and conditions are subject to the applicable Daikin warranty documentation.

Recommended Accessories

  • Compatible Daikin Roof Curb – DSG Series 3–6 Ton Accessory
  • Outdoor Thermostat with Housing for Gas Models
  • Compatible Downflow Square-to-Round Adapter – DSG Series Accessory
  • Compatible Horizontal Square-to-Round Adapter – DSG Series Accessory
  • Compatible Economizer – DSG Series 3–6 Ton Accessory

Reliable Year-Round Comfort with the Daikin DSG0363DH00001S

Experience reliable year-round commercial comfort with the Daikin DSG0363DH00001S. Combining two-stage gas heating and efficient 35,000 BTU/h electric cooling in one direct-drive packaged rooftop system, this 3-ton unit provides a practical, space-saving solution for light commercial applications.

Please note that this Package Unit cannot be installed in the following counties in California: Fresno, Joaquin, Kern, Kings, Los Angeles, Madera, Merced, Orange, Riverside, San Bernardino, San Stanislaus, and Tulare. In these counties you are required to purchase an Ultra-Low NOx system. If you have any questions, please contact us.

Packaged Unit Buyers Guide

  • How packaged units work for residential and commercial use
  • The different types of packaged units
  • Figuring out the right size unit for your needs
  • The importance of a custom curb adapter
  • And much more!
More Information
Daikin 3 Ton 90,000 BTU 14 SEER2 Commercial Gas Packaged Unit | 208/230V 3 Phase - R32 - Single Stage
FeatureSpec
SKUDSG0363DH00001S
Refrigerant ChargePre-charged
Weight (in lbs)510
AHRI Certificate Number215414875
Brand/ManufacturerDaikin
ReplacesDFG0363DH00001S
UPC633190263926
Cooling BTU35,000
Heating BTU90,000 BTU
Drive TypeDirect
Maximum CFM1160
Motor RPM1200
HorsepowerIndoor Horsepower: 3/4, Outdoor Horsepower: 1/6
RefrigerantR32
SEER2 (Efficiency)14
EER212
Electrical208/230 V. 3 Phase 60 Hz
PhaseThree Phase
Max Breaker Size30 Amps
Min. Breaker Size19.9 Amps
Tonnage3 Ton
Height39-7/8"
Width48-5/16"
Depth74"
Warranty5 Years with Online Registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety Information
This gas appliance requires a trained technician to install. Improperly connecting gas lines or improperly connecting a gas flue or venting may result in death. By purchasing this item, you are agreeing that you are using a trained technician to install this gas appliance. We will not be responsible for any injury or property damage arising from improper service or service procedures. Whoever installs or services this unit assumes responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install this equipment.

PROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Daikin 3 Ton 90,000 BTU 14 SEER2 Commercial Gas Packaged Unit | 208/230V 3 Phase - R32 - Single Stage
Your Rating
Customer Questions
How do I register my Daikin Package Unit for its warranty?
Hello, to register your Daikin Package Rooftop unit for its warranty, please contact the HVAC Technician/Contractor that installed your system or check out the following link for more information about your warranty: Click Here
What types of buildings use Rooftop Gas Packaged Units?
Commercial Gas Package Units are commonly used for: Retail Stores Restaurants Churches Warehouses Office Buildings Schools Light Industrial Facilities Most Gas Package Units can be used on a rooftop or at ground level
How does a Commercial Gas Packaged Unit work?
Commercial Gas Packaged Unit uses two separate heating and cooling methods: Cooling Mode The electric air conditioning system removes heat from the building. A scroll compressor circulates refrigerant to provide cooling. Heating Mode Natural gas is burned inside the furnace section. Heated air is distributed through the ductwork. Your Commercial Gas Packaged Unit will automatically switch between heating and cooling based on thermostat demand
What is the life expectancy of the typical Commercial Gas Packaged Rooftop Unit?
The typical life expectancy of a Commercial Gas Rooftop Packaged Unit is approximately 15–20 years with proper installation and routine preventative maintenance. Factors such as operating hours, weather exposure, maintenance frequency, and overall operating conditions can affect equipment longevity. Regular filter changes, coil cleaning, inspections, and servicing of burners and heat exchangers can help extend the unit's lifespan.
Can a Commercial Gas Packaged Unit provide suitable year-round operation?
Yes. A commercial gas packaged unit provides year-round heating and cooling by combining a gas furnace for heating with an electric air conditioner for cooling in one self-contained system. During colder months, the gas furnace provides reliable heat, while the cooling components operate during warmer months to maintain comfortable indoor temperatures. This makes gas packaged units a versatile HVAC solution for commercial buildings that require heating and cooling throughout the year.
What does BTU and Tonnage Mean?
BTU (British Thermal Unit) measures the amount of heating or cooling energy a commercial rooftop packaged unit can produce per hour, while tonnage measures the unit's nominal cooling capacity. One ton of cooling equals 12,000 BTU/h, meaning a 10-ton commercial rooftop unit provides approximately 120,000 BTU/h of cooling capacity. Both measurements help contractors and customers determine the appropriate HVAC system size and output for a building's heating and cooling requirements.
What accessories or additional components are needed to install a Commercial Rooftop Units?
Installing a commercial rooftop unit may require several accessories and additional components depending on the building's existing setup and installation requirements. Common components include a roof curb or curb adapter, ductwork transitions, electrical disconnects, thermostats, economizers, dampers, and supplemental heating kits when applicable. Additional accessories, such as hail guards, smoke detectors, and condensate drain components, may also be recommended based on the application. Always verify equipment compatibility and manufacturer installation requirements before purchasing additional components.
Can I replace my existing Commercial Rooftop Unit without replacing the ductwork?
Yes. In many cases, an existing commercial rooftop unit can be replaced without replacing the current ductwork, provided the duct system is in good condition and compatible with the new equipment. Before installation, an HVAC professional should evaluate the ductwork, airflow requirements, unit capacity, and existing connections to ensure proper system performance. Additional modifications may be necessary if the new unit has different dimensions, airflow configurations, or connection requirements.
What is the difference between EER and IEER ratings on Commercial Rooftop Units?
EER (Energy Efficiency Ratio) and IEER (Integrated Energy Efficiency Ratio) are ratings used to measure the cooling efficiency of commercial HVAC equipment. EER measures how efficiently a unit operates under specific full-load outdoor temperature and operating conditions, while IEER evaluates efficiency across multiple operating conditions, including part-load performance. IEER provides a broader picture of how efficiently a commercial rooftop unit operates under varying cooling demands throughout the year. Higher EER and IEER ratings generally indicate greater energy efficiency and potentially lower operating costs.
Can a Commercial Rooftop Unit be installed on the ground instead of the roof?
Yes. Some commercial packaged rooftop units can be installed at ground level when the equipment is designed for horizontal airflow rather than vertical rooftop discharge. These horizontal-flow units require adequate space, a stable mounting surface, proper ductwork connections, and sufficient clearance for airflow and servicing. Always verify the manufacturer's installation requirements and local building codes before selecting a ground-level installation.
Do Commercial Rooftop Units require professional installation?
Yes. Commercial rooftop units should be installed by qualified HVAC professionals to ensure proper equipment placement, electrical connections, ductwork compatibility, refrigerant handling, and system performance. Professional installation helps ensure the unit operates safely and efficiently while meeting applicable building codes, manufacturer requirements, and local regulations.
Did you find what you were looking for?
blockboard tech