Product Features
  • Designed for Easy Retrofit Installs
  • Custom Roof Curbs designed to fit your current adapter!
  • Precharged with R32 Refrigerant
  • Single Stage Condenser
  • 208/230V 3 Phase
  • Up to a 5 Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

Reliable 5-Ton Heat Pump for Light Commercial Applications with Direct-Drive Rooftop Design

The Daikin DSH0603D000001S is a 5-ton commercial packaged heat pump designed to provide dependable heating and cooling for light commercial buildings. Combining 55,000 Btu/h of nominal heating capacity with 57,500 Btu/h of cooling capacity, this all-in-one rooftop system helps deliver year-round comfort while simplifying installation and preserving valuable indoor space.

Key Benefits

  • Efficient R-32 Operation – Uses R-32 refrigerant and provides up to 13.7 SEER2 and 11.8 EER2 across the DSH 3-6 ton series.
  • Heat Pump Heating – Provides 55,000 Btu/h of nominal heating capacity for dependable comfort during heating operation.
  • Commercial Cooling Performance – Delivers 57,500 Btu/h of nominal cooling capacity for light commercial comfort applications.
  • Installation Flexibility – Packaged rooftop construction is designed for fast installation in both new construction and retrofit projects and can directly replace many existing rooftop units with a curb adapter.
  • Rooftop Space Savings – Combines heating, cooling, fan, controls, and other major components in one outdoor cabinet, helping preserve valuable indoor space.
  • Durable Construction – Galvanized steel cabinet with powder-paint finish provides increased corrosion resistance for long-lasting outdoor performance.
  • Direct-Drive Airflow – Direct-drive supply fan provides efficient, quiet operation and easy airflow control across a range of static pressure and airflow requirements.
  • Service-Friendly Design – Weatherproof internal control box is organized for easy access, while the standard draw-through filter section supports air quality and component maintenance.

Direct-Drive Heat Pump Heating

The integrated heat pump system provides 55,000 Btu/h of nominal heating capacity to help maintain comfortable indoor temperatures during heating operation. The DSH series also supports a wide range of electric heat selections, allowing supplemental electric heating options to address a variety of commercial comfort requirements.

High-Capacity Cooling Performance

The single-stage scroll compressor and packaged cooling system provide 57,500 Btu/h of nominal cooling capacity. The DSH0603D000001S has a rated efficiency of 13.7 SEER2 and 11.8 EER2, helping support efficient cooling operation in light commercial applications.

R-32 Refrigerant Efficiency

The DSH0603D000001S uses R-32 refrigerant and a high-performance, low-noise scroll compressor. The DSH 3-6 ton series offers up to 13.7 SEER2 and 11.8 EER2, while the large-face-area outdoor coils use microchannel technology to support efficient heat transfer and operation.

Packaged Rooftop Installation Design

The packaged rooftop configuration combines the heat pump system, compressor, coils, supply fan, controls, and filtration into a single outdoor unit, helping simplify equipment placement and preserve valuable indoor space. Daikin designed the packaged units for fast and easy installation in both new construction and retrofit projects, with the ability to directly replace most rooftop units in the field with a curb adapter. The unit is also factory wired and tested to help support faster commissioning and startup.

Controls & Comfort

The unit includes a weatherproof internal control box with an organized layout and easy access. Compatible Daikin light commercial controls include commercial programmable and Wi-Fi-capable thermostats, heat pump thermostats, remote sensors, and other control accessories for 3-25 ton packaged equipment. The direct-drive supply fan also provides airflow control for varying static pressure and airflow requirements.

Light Commercial Applications

The Daikin DSH0603D000001S is designed for light commercial rooftop applications, including spaces such as offices, retail facilities, restaurants, schools, hotels, and other commercial buildings requiring packaged heating and cooling. Its 5-ton capacity, rooftop configuration, direct-drive airflow system, and flexible installation design make it well suited for both new construction and retrofit applications.

Service & Maintenance

The unit provides a standard draw-through filter section to support air quality and long-lasting component maintenance. A weatherproof internal control box provides convenient access to controls and wiring, while the direct-drive supply fan eliminates the need for traditional belt-driven fan maintenance. The galvanized steel cabinet with powder-paint finish is designed to provide increased corrosion resistance for outdoor use.

Warranty

The Daikin DSH Series includes a 5-year limited parts warranty for light commercial applications. Warranty coverage is subject to the applicable Daikin warranty terms and conditions.

Recommended Accessories

Reliable Commercial Comfort with the Daikin DSH0603D000001S

Experience dependable year-round comfort with the Daikin DSH0603D000001S. Combining a 55,000 Btu/h heat pump heating system and 57,500 Btu/h cooling system in one direct-drive packaged rooftop unit, it provides a practical solution for light commercial heating and cooling while supporting efficient operation, flexible installation, and convenient service.

Packaged Unit Buyers Guide

  • How packaged units work for residential and commercial use
  • The different types of packaged units
  • Figuring out the right size unit for your needs
  • The importance of a custom curb adapter
  • And much more!
More Information
Daikin 5 Ton 13.7 SEER2 Commercial Packaged Heat Pump | 208/230V 3 Phase - R32 - Single Stage
FeatureSpec
SKUDSH0603D000001S
Refrigerant ChargePre-charged
Weight (in lbs)666
AHRI Certificate Number210643295
Brand/ManufacturerDaikin
ReplacesDFH0603D000001S
UPC634707251092
Additional InformationUses four 14" x 20" x 2" filters
Cooling BTU57,500 BTU
Heating BTU55,000 BTU
Drive TypeDirect
Maximum CFM1870
Decibel Level (dBA)79 Decibels
Motor RPM1122
HorsepowerIndoor: 1.00, Outdoor: 1/3
RefrigerantR32
HSPF26.90
SEER2 (Efficiency)13.7
EER211.8
Condenser StagesSingle Stage
Compressor TypeScroll
Electrical208/230v 3 Phase 60 Hz
PhaseThree Phase
Max Breaker Size45/45 Amps
Min. Breaker Size30.5/30.5 Amps
Tonnage5 Ton
Height39 7/8"
Width74"
Depth48 5/16"
Warranty20 Years Heat Exchanger and 5 Years Parts with Online Registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Daikin 5 Ton 13.7 SEER2 Commercial Packaged Heat Pump | 208/230V 3 Phase - R32 - Single Stage
Your Rating
Customer Questions
What does BTU and Tonnage Mean?
BTU (British Thermal Unit) measures the amount of heating or cooling energy a commercial rooftop packaged unit can produce per hour, while tonnage measures the unit's nominal cooling capacity. One ton of cooling equals 12,000 BTU/h, meaning a 10-ton commercial rooftop unit provides approximately 120,000 BTU/h of cooling capacity. Both measurements help contractors and customers determine the appropriate HVAC system size and output for a building's heating and cooling requirements.
What accessories or additional components are needed to install a Commercial Rooftop Units?
Installing a commercial rooftop unit may require several accessories and additional components depending on the building's existing setup and installation requirements. Common components include a roof curb or curb adapter, ductwork transitions, electrical disconnects, thermostats, economizers, dampers, and supplemental heating kits when applicable. Additional accessories, such as hail guards, smoke detectors, and condensate drain components, may also be recommended based on the application. Always verify equipment compatibility and manufacturer installation requirements before purchasing additional components.
Can I replace my existing Commercial Rooftop Unit without replacing the ductwork?
Yes. In many cases, an existing commercial rooftop unit can be replaced without replacing the current ductwork, provided the duct system is in good condition and compatible with the new equipment. Before installation, an HVAC professional should evaluate the ductwork, airflow requirements, unit capacity, and existing connections to ensure proper system performance. Additional modifications may be necessary if the new unit has different dimensions, airflow configurations, or connection requirements.
What is the difference between EER and IEER ratings on Commercial Rooftop Units?
EER (Energy Efficiency Ratio) and IEER (Integrated Energy Efficiency Ratio) are ratings used to measure the cooling efficiency of commercial HVAC equipment. EER measures how efficiently a unit operates under specific full-load outdoor temperature and operating conditions, while IEER evaluates efficiency across multiple operating conditions, including part-load performance. IEER provides a broader picture of how efficiently a commercial rooftop unit operates under varying cooling demands throughout the year. Higher EER and IEER ratings generally indicate greater energy efficiency and potentially lower operating costs.
What are the different types of Commercial Rooftop HVAC Units?
Commercial rooftop HVAC units are available in several configurations designed to meet different building heating and cooling requirements. The most common types include cooling-only air conditioner units, gas/electric packaged units, heat pump units, and dual-fuel units. These systems combine major HVAC components into a single outdoor cabinet, providing centralized temperature control for commercial spaces. The best option depends on the building's heating and cooling needs, energy requirements, and installation specifications.
How does a Commercial Rooftop Heat Pump Unit work?
A commercial rooftop heat pump works by transferring heat between the indoor and outdoor environments to provide both heating and cooling. During warmer months, the system removes heat from indoor air and transfers it outside to cool the building. During colder months, the refrigeration cycle reverses, extracting heat from outdoor air and transferring it indoors to provide warmth. This allows a single packaged rooftop unit to deliver year-round temperature control without relying on a traditional gas furnace.
How well do Commercial Rooftop Heat Pumps work in freezing temperatures?
Commercial rooftop heat pumps can provide heating in freezing temperatures by extracting available heat from outdoor air and transferring it indoors. However, heating capacity and efficiency generally decrease as outdoor temperatures drop, and performance varies depending on the unit's design and operating temperature range. Many commercial rooftop heat pumps include supplemental electric heat to maintain indoor comfort during extremely cold conditions. Always check the manufacturer's published low-ambient operating limits and heating performance specifications when selecting a unit for colder climates.
Does a Commercial Heat Pump require supplemental electric heat?
A commercial rooftop heat pump does not always require supplemental electric heat, but it can be beneficial in colder climates or during periods of extremely low outdoor temperatures. As temperatures drop, a heat pump's heating capacity and efficiency typically decrease, making supplemental electric heat useful for maintaining comfortable indoor temperatures when the system cannot meet the building's heating demand on its own. Whether supplemental heat is necessary depends on the unit's heating capacity, operating temperature range, building requirements, and local climate.
What is a good efficiency rating for a Commercial Rooftop Heat Pump?
A good efficiency rating for a commercial rooftop heat pump depends on the unit's size, application, and operating requirements. When comparing models, look at SEER2 and EER2 ratings for cooling efficiency and COP (Coefficient of Performance) or heating performance ratings for heating efficiency. Higher ratings generally indicate better energy efficiency and lower operating costs. IEER is also an important rating to consider for commercial rooftop equipment because it measures cooling efficiency under varying operating conditions and part-load capacities. Always compare ratings within the same equipment category and capacity range when selecting a commercial rooftop heat pump.
What types of Commercial buildings benefit most from Rooftop Heat Pump Units?
Commercial rooftop heat pump units are ideal for buildings that require reliable year-round heating and cooling, including offices, retail stores, restaurants, schools, warehouses, and light industrial facilities. They are especially beneficial for businesses looking for an energy-efficient, all-electric HVAC solution that provides both heating and cooling in one self-contained system. Rooftop heat pumps can also help free up indoor space by housing major HVAC components outside the building.
Did you find what you were looking for?
blockboard tech