Daikin 5 Ton 14.3 SEER2 Commercial Heat Pump Condenser | 460V 3 Phase - R32 - Single Stage

Daikin 5 Ton 14.3 SEER2 Commercial Heat Pump Condenser | 460V 3 Phase - R32 - Single Stage
By

Daikin

In stock
Model

DH4SEA6040

ID

192123

$4,300.00
ONLY 2 LEFT!
Free Shipping
 
Product Features
  • Save by Purchasing a Complete Commercial System!
  • Precharged with R32 Refrigerant
  • Single Stage Condenser
  • 460V 3 Phase
  • Up to a 5 Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

Efficient 5-Ton Commercial Split Heat Pump for Light Commercial Applications with R-32 Refrigerant

The Daikin DH4SEA6040 is a 5-ton commercial split heat pump system designed to provide reliable year-round heating and cooling for light commercial applications. Combining the 60,000 BTU/h DH4SEA6040 outdoor heat pump unit with a compatible indoor coil or air handler, this split system helps deliver dependable comfort while providing flexible equipment placement and ducted installation options.

Key Benefits

  • 14.3 SEER2 Efficiency – Provides efficient seasonal cooling performance to help manage energy use during commercial operation.
  • 8.2 HSPF2 Heating Efficiency – Provides efficient heat pump heating performance during the heating season.
  • 60,000 BTU/h Cooling Capacity – Provides nominal 5-ton cooling capacity for commercial comfort applications.
  • Single-Stage Copeland Scroll Compressor – Provides reliable compressor operation for consistent heating and cooling performance.
  • R-32 Refrigerant – Uses R-32 refrigerant in a purpose-designed commercial heat pump platform.
  • Flexible Split System Installation – Separates the outdoor heat pump from the indoor coil or air handler, providing flexibility for equipment placement and ducted applications.
  • Durable Outdoor Cabinet – Features a custom Nickel Gray powder-paint finish with 500-hour salt-spray approval and a steel louver coil guard with rust-resistant screws for added outdoor durability.
  • Advanced Compressor Protection – Copeland CoreSense technology, high- and low-pressure switches, a factory-installed suction line accumulator, and compressor crankcase heater help support dependable operation.
  • Service-Friendly Design – Top and side maintenance access, single-panel access to controls, service valves with easy-access gauge ports, and space for field-installed accessories simplify service procedures.

Reliable Heat Pump Heating Performance

The DH4SEA6040 provides a rated heating capacity of 60,000 BTU/h at 47°F outdoor ambient temperature and is designed to operate in heating mode from -20°F to 70°F outdoor ambient temperature. The system uses a single-stage Copeland scroll compressor with advanced CoreSense technology. Time-delay technology helps provide quiet, reliable defrost operation, while the factory-installed compressor crankcase heater and suction line accumulator support dependable heat pump operation.

60,000 BTU/h Cooling Performance

The DH4SEA6040 provides a nominal cooling capacity of 60,000 BTU/h. The AHRI-rated high sales volume tested combination provides a rated cooling capacity of 57,300 BTU/h with a 12.50 EER2 and 14.30 SEER2. The outdoor unit is designed for a cooling operating range of 55°F to 125°F outdoor ambient temperature, supporting dependable cooling operation across a broad range of commercial conditions.

14.3 SEER2 & 8.2 HSPF2 Efficiency

With up to 14.3 SEER2 cooling efficiency and 8.2 HSPF2 heating efficiency, the DH4SEA6040 is designed to provide efficient seasonal heating and cooling performance. The system combines a high-efficiency Copeland scroll compressor with an enhanced aluminum fin coil using 7mm diameter copper tubes, a factory-installed bi-flow liquid line filter drier, a factory-installed suction line accumulator, and a high-capacity muffler. The unit is AHRI Certified and ETL Listed.

Split System Installation Design

The split system configuration separates the DH4SEA6040 outdoor heat pump from the compatible indoor coil or air handler, providing flexibility for equipment placement and ducted commercial installation. The outdoor unit operates on 460V, 60 Hz, three-phase power with a minimum circuit ampacity of 10.4 amps and maximum overcurrent protection of 15 amps. It uses a 3/8-inch liquid line and 1-1/8-inch suction line, is factory charged for 15 feet of 3/8-inch liquid tubing, and supports a maximum total piping length of 200 feet and maximum vertical piping length of 79 feet. The outdoor unit measures 36.6 inches high by 35.5 inches wide by 35.5 inches deep and weighs 288 pounds net.

Controls & Comfort

The DH4SEA6040 is designed for conventional heat pump control with a compatible indoor coil or air handler and thermostat. Its single-stage compressor provides straightforward heating and cooling operation, while time-delay technology supports quiet and reliable defrost operation. The system's conventional control configuration allows the outdoor heat pump to operate with compatible indoor equipment and field-installed controls.

Commercial Applications

The Daikin DH4SEA6040 is designed for 5-ton, three-phase commercial split heat pump applications requiring 460V electrical service and ducted indoor air distribution. Its flexible split configuration, wide heating operating range, durable outdoor cabinet, and service-access features make it suitable for light commercial comfort applications where dependable heating and cooling performance are required.

Service & Maintenance

The DH4SEA6040 features top and side maintenance access and single-panel access to the controls with space provided for field-installed accessories. Brass service valves with sweat connections provide easy access to gauge ports. The refrigeration system includes a factory-installed bi-flow liquid line filter drier, suction line accumulator, compressor crankcase heater, and high-capacity muffler. High- and low-pressure switches provide additional system protection, while extended-life capacitors and a fully enclosed contactor with lug connections support reliable operation.

Warranty

The Daikin DH4SEA6040 includes a 5-Year Parts Limited Warranty. To receive the 5-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. The duration of warranty coverage may depend on the state or province where the product is installed. Some states and provinces do not allow warranty coverage to be conditioned on registration. Other limitations and exclusions apply; refer to the complete Daikin warranty documentation for applicable terms and conditions.

Recommended Accessories

  • Anchor Bracket Kit – Provides brackets for anchoring the outdoor unit to a mounting pad; four brackets are required to anchor the unit.
  • Anti-Short Cycle Kit – Provides an accessory option for applications requiring anti-short-cycle protection.
  • Hard-Start Kit – Provides a hard-start accessory option for compatible installations.
  • Freeze Protection Kit – Provides freeze protection for applicable indoor coil installations.
  • Liquid Line Solenoid Kit – Provides a liquid line solenoid accessory option for compatible system installations.
  • Low-Ambient Kit – Provides a low-ambient accessory option for applications requiring extended cooling operation.
  • Outdoor Thermostat with Lockout Stat – Provides an outdoor thermostat option for applicable heat pump installations.

Efficient Commercial Heating & Cooling with the Daikin DH4SEA6040

Experience reliable year-round commercial comfort with the Daikin DH4SEA6040. Combining 60,000 BTU/h nominal heat pump capacity, up to 14.3 SEER2 cooling efficiency, 8.2 HSPF2 heating efficiency, and durable R-32 system construction in one 5-ton commercial split heat pump system.

Upgrade to a Complete Commercial Split System!

Upgrading to a commercial split HVAC system can lead to significant savings over the life of the equipment. We offer full systems (condenser + air handler) specifically designed for commercial spaces, so you get the performance and capacity you need. At HVACDirect.com, we make it simple to find the right solution for your business with financing options starting at $0 down and an extra 3% discount on orders over $2,000!

More Information
Daikin 5 Ton 14.3 SEER2 Commercial Heat Pump Condenser | 460V 3 Phase - R32 - Single Stage
FeatureSpec
SKUDH4SEA6040
Refrigerant ChargePre-Charged For: 15'
Weight (in lbs)261
Brand/ManufacturerDaikin
ReplacesDZ14SA0604
UPC634707283246
Cooling BTU56,500 BTU
Heating BTU59,000 BTU
Decibel Level (dBA)75 decibels
RefrigerantR32
SEER1 (Efficiency)14
SEER2 (Efficiency)14.3
EER11.5
Condenser StagesSingle Stage
Compressor TypeScroll
Liquid Line3/8"
Suction Line1 1/8"
Liquid Valve Size3/8"
Suction Valve Size7/8" (4)
Electrical460 V. 3 Phase 60 Hz
PhaseThree Phase
Max Breaker Size15 amps
Min. Breaker Size10.6 amps
Tonnage5 Ton
Height34.25"
Width35.5"
Depth35.5"
Warranty5 Years Parts with Online Registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Daikin 5 Ton 14.3 SEER2 Commercial Heat Pump Condenser | 460V 3 Phase - R32 - Single Stage
Your Rating
Customer Questions
What type of maintenance does this commercial split A/C require?
Routine maintenance includes filter replacement, coil cleaning, refrigerant level checks, and inspection of electrical components. Scheduling professional service at least twice a year helps extend the system’s lifespan and ensures optimal performance. If you have any further questions, please call us and we will be happy to assist you.
What type of space is this unit designed for?
Commercial split air conditioners are a reliable cooling solution for businesses that require efficient climate control across various building types, including offices, retail stores, and light industrial spaces. Amongst other types of businesses as well. If you have any further questions, please call us and we will be happy to assist you.
How does this commercial split heat pump work?
This commercial split heat pump transfers heat using refrigerant. In cooling mode, it removes heat from inside the building; in heating mode, it reverses the cycle to bring in heat from outside. This dual function makes it a year-round HVAC solution. If you have any further questions, please call us and we will be happy to assist you.
Can commercial split heat pumps be integrated with existing HVAC systems?
Yes, this commercial split heat pump can often be integrated with existing ductwork and control systems, making it a flexible upgrade option for buildings that need more efficient, modern heating and cooling without a complete system overhaul. If you have any further questions, please call us and we will be happy to assist you.