Daikin 6 Ton 140,000 BTU 16.7 IEER Commercial Gas Packaged Unit | 460V 3 Phase - R32 - Two Stage

SAVE $1,080.00
By

Daikin

In stock
Model

DSG0724DH00001S

ID

190769

Was $8,280.00 Your Low Price Special Price $7,200.00
Ships in 5-7 Business Days
Free Shipping
 
Product Features
  • Designed for Easy Retrofit Installs
  • Custom Roof Curbs designed to fit your current adapter!
  • Precharged with R32 Refrigerant
  • 2-Stage Condenser
  • 460V 3 Phase
  • Up to 20-Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

High-Capacity Heating and Cooling Gas/Electric Packaged Rooftop Unit for Light Commercial Applications

The Daikin DSG0724DH00001S is a 6-ton commercial gas/electric packaged rooftop unit designed to provide reliable year-round heating and cooling for light commercial buildings. Combining 140,000 BTU/h high-stage gas heating input with 69,000 BTU/h of cooling capacity, this all-in-one rooftop system helps deliver dependable comfort while simplifying installation and preserving valuable indoor space.

Key Benefits

  • 16.7 SEER2 / 11.8 EER2 Cooling Efficiency – Helps provide efficient cooling performance for light commercial comfort applications.
  • Two-Stage Gas Heating – Provides high- and low-stage heating operation to help match heating output to changing comfort requirements.
  • High-Performance Scroll Compressor – Provides reliable cooling operation with a proven scroll compressor design.
  • Direct-Drive Indoor Fan – Provides dependable airflow while eliminating belt-driven fan maintenance.
  • Packaged Rooftop Configuration – Combines heating and cooling components in one outdoor unit to help preserve valuable indoor space.
  • Durable Galvanized-Steel Cabinet – Provides a durable outdoor enclosure designed for dependable rooftop installation.
  • Factory-Wired and Tested – Helps support efficient installation, commissioning, and start-up.
  • Accessible Service Design – Accessible components and filter sections help simplify routine service and maintenance.

Two-Stage Gas Heating for Reliable Comfort

The integrated gas furnace provides 140,000 BTU/h high-stage heating input and 112,000 BTU/h high-stage heating output. Two-stage heating operation helps match heating output to changing comfort requirements. The heating section uses six burners and a tubular heat exchanger to provide dependable gas heating performance in a self-contained rooftop configuration.

69,000 BTU/h Cooling Performance

The single-stage scroll compressor provides 69,000 BTU/h of nominal cooling capacity with a 16.7 SEER2 and 11.8 EER2 efficiency rating. The system uses R-32 refrigerant and a microchannel condenser coil to support efficient cooling operation. This combination helps provide dependable cooling performance for light commercial spaces during warm-weather operation.

High-Efficiency Performance with Direct-Drive Operation

With a 16.7 SEER2 and 11.8 EER2 cooling efficiency rating, the DSG0724DH00001S is designed to provide efficient commercial cooling performance. The direct-drive indoor fan provides dependable airflow without the belts and pulleys associated with traditional belt-driven blower systems, while the scroll compressor provides reliable cooling operation.

Packaged Rooftop Design for Flexible Installation

The packaged rooftop configuration combines the gas furnace, compressor, coils, indoor fan, and controls into a single outdoor unit, helping simplify equipment placement and preserve valuable indoor space. Daikin packaged rooftop units are designed for new construction and retrofit applications and are built to be direct replacements for most rooftop units without the need for a curb adapter. The DSG0724DH00001S uses a 460-volt, three-phase, 60 Hz electrical supply and measures 74 inches wide by 48 5/8 inches deep by 43 1/2 inches high, with an overall height of 79 inches. The unit has a shipping weight of 688 pounds.

Controls & Comfort

The DSG0724DH00001S uses a factory-installed controls package with a weatherproof internal control box designed for convenient access. Two-stage gas heating provides high- and low-stage operation, while the direct-drive indoor fan supports controlled airflow for dependable commercial comfort.

Commercial Applications

The Daikin DSG0724DH00001S is designed for light commercial rooftop applications where dependable gas heating and electric cooling are required from a single packaged system. Its 6-ton capacity, two-stage gas heating, direct-drive indoor fan, and packaged rooftop configuration make it well suited for applications such as retail spaces, offices, restaurants, schools, warehouses, and other light commercial buildings.

Service & Maintenance

The DSG0724DH00001S is designed with service accessibility in mind, including accessible service components and a convenient filter section. The refrigeration system includes a bi-flow filter drier and high- and low-pressure switches, while factory wiring and testing help support commissioning and start-up. The direct-drive indoor fan eliminates belt and pulley maintenance associated with belt-driven blower systems.

Warranty

The Daikin DSG0724DH00001S includes a 20-year heat exchanger limited warranty and a 5-year parts limited warranty. Complete warranty terms and conditions are subject to the applicable Daikin warranty documentation.

Recommended Accessories

  • Compatible Daikin Roof Curb – DSG Series 3–6 Ton Accessory
  • Outdoor Thermostat with Housing for Gas Models – OTDPFKG-01
  • Compatible Downflow Square-to-Round Adapter – DSG Series Accessory
  • Compatible Horizontal Square-to-Round Adapter – DSG Series Accessory
  • Compatible Economizer – DSG Series 3–6 Ton Accessory

High-Capacity Year-Round Comfort with the Daikin DSG0724DH00001S

Experience reliable year-round commercial comfort with the Daikin DSG0724DH00001S. Combining two-stage gas heating and efficient 69,000 BTU/h electric cooling in one direct-drive packaged rooftop system, this 6-ton unit provides a practical, space-saving solution for light commercial applications.

Packaged Unit Buyers Guide

  • How packaged units work for residential and commercial use
  • The different types of packaged units
  • Figuring out the right size unit for your needs
  • The importance of a custom curb adapter
  • And much more!
More Information
Daikin 6 Ton 140,000 BTU 16.7 IEER Commercial Gas Packaged Unit | 460V 3 Phase - R32 - Two Stage
FeatureSpec
SKUDSG0724DH00001S
Refrigerant ChargePre-charged
Weight (in lbs)626
Brand/ManufacturerDaikin
ReplacesDFG0724DH00001S
UPC633190264381
Furnace Efficiency / AFUE 80%
Cooling BTU69,000 BTU
Heating BTU140,000
Maximum CFM2100
Decibel Level (dBA)78 decibels
Motor RPM1500
HorsepowerIndoor Horsepower: 1.2, Outdoor Horsepower: 1/3
RefrigerantR32
SEER2 (Efficiency)14.3
EER11.8
IEER16.7
Condenser StagesTwo Stage
Electrical460V. 3 Phase 60 Hz
PhaseThree Phase
Max Breaker Size12.2 Amps
Min. Breaker Size20 Amps
Tonnage6 Ton
Height43 1/2"
Width48 5/16"
Depth74"
Warranty20 Years Heat Exchanger, 5 Years Parts with Online Registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety Information
This gas appliance requires a trained technician to install. Improperly connecting gas lines or improperly connecting a gas flue or venting may result in death. By purchasing this item, you are agreeing that you are using a trained technician to install this gas appliance. We will not be responsible for any injury or property damage arising from improper service or service procedures. Whoever installs or services this unit assumes responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install this equipment.

PROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Daikin 6 Ton 140,000 BTU 16.7 IEER Commercial Gas Packaged Unit | 460V 3 Phase - R32 - Two Stage
Your Rating
Customer Questions
How do I register my Daikin Package Unit for its warranty?
Hello, to register your Daikin Package Rooftop unit for its warranty, please contact the HVAC Technician/Contractor that installed your system or check out the following link for more information about your warranty: Click Here
What types of buildings use Rooftop Gas Packaged Units?
Commercial Gas Package Units are commonly used for: Retail Stores Restaurants Churches Warehouses Office Buildings Schools Light Industrial Facilities Most Gas Package Units can be used on a rooftop or at ground level
How does a Commercial Gas Packaged Unit work?
Commercial Gas Packaged Unit uses two separate heating and cooling methods: Cooling Mode The electric air conditioning system removes heat from the building. A scroll compressor circulates refrigerant to provide cooling. Heating Mode Natural gas is burned inside the furnace section. Heated air is distributed through the ductwork. Your Commercial Gas Packaged Unit will automatically switch between heating and cooling based on thermostat demand
What is the life expectancy of the typical Commercial Gas Packaged Rooftop Unit?
The typical life expectancy of a Commercial Gas Rooftop Packaged Unit is approximately 15–20 years with proper installation and routine preventative maintenance. Factors such as operating hours, weather exposure, maintenance frequency, and overall operating conditions can affect equipment longevity. Regular filter changes, coil cleaning, inspections, and servicing of burners and heat exchangers can help extend the unit's lifespan.
Can a Commercial Gas Packaged Unit provide suitable year-round operation?
Yes. A commercial gas packaged unit provides year-round heating and cooling by combining a gas furnace for heating with an electric air conditioner for cooling in one self-contained system. During colder months, the gas furnace provides reliable heat, while the cooling components operate during warmer months to maintain comfortable indoor temperatures. This makes gas packaged units a versatile HVAC solution for commercial buildings that require heating and cooling throughout the year.
What does BTU and Tonnage Mean?
BTU (British Thermal Unit) measures the amount of heating or cooling energy a commercial rooftop packaged unit can produce per hour, while tonnage measures the unit's nominal cooling capacity. One ton of cooling equals 12,000 BTU/h, meaning a 10-ton commercial rooftop unit provides approximately 120,000 BTU/h of cooling capacity. Both measurements help contractors and customers determine the appropriate HVAC system size and output for a building's heating and cooling requirements.
What accessories or additional components are needed to install a Commercial Rooftop Units?
Installing a commercial rooftop unit may require several accessories and additional components depending on the building's existing setup and installation requirements. Common components include a roof curb or curb adapter, ductwork transitions, electrical disconnects, thermostats, economizers, dampers, and supplemental heating kits when applicable. Additional accessories, such as hail guards, smoke detectors, and condensate drain components, may also be recommended based on the application. Always verify equipment compatibility and manufacturer installation requirements before purchasing additional components.
Can I replace my existing Commercial Rooftop Unit without replacing the ductwork?
Yes. In many cases, an existing commercial rooftop unit can be replaced without replacing the current ductwork, provided the duct system is in good condition and compatible with the new equipment. Before installation, an HVAC professional should evaluate the ductwork, airflow requirements, unit capacity, and existing connections to ensure proper system performance. Additional modifications may be necessary if the new unit has different dimensions, airflow configurations, or connection requirements.
What is the difference between EER and IEER ratings on Commercial Rooftop Units?
EER (Energy Efficiency Ratio) and IEER (Integrated Energy Efficiency Ratio) are ratings used to measure the cooling efficiency of commercial HVAC equipment. EER measures how efficiently a unit operates under specific full-load outdoor temperature and operating conditions, while IEER evaluates efficiency across multiple operating conditions, including part-load performance. IEER provides a broader picture of how efficiently a commercial rooftop unit operates under varying cooling demands throughout the year. Higher EER and IEER ratings generally indicate greater energy efficiency and potentially lower operating costs.
Can a Commercial Rooftop Unit be installed on the ground instead of the roof?
Yes. Some commercial packaged rooftop units can be installed at ground level when the equipment is designed for horizontal airflow rather than vertical rooftop discharge. These horizontal-flow units require adequate space, a stable mounting surface, proper ductwork connections, and sufficient clearance for airflow and servicing. Always verify the manufacturer's installation requirements and local building codes before selecting a ground-level installation.
Do Commercial Rooftop Units require professional installation?
Yes. Commercial rooftop units should be installed by qualified HVAC professionals to ensure proper equipment placement, electrical connections, ductwork compatibility, refrigerant handling, and system performance. Professional installation helps ensure the unit operates safely and efficiently while meeting applicable building codes, manufacturer requirements, and local regulations.
Did you find what you were looking for?
blockboard tech