Daikin 8.5 Ton 11.4 EER Light Commercial Packaged Heat Pump | 208/230V 3 Phase - R32 - Single Stage

SAVE $1,885.00
By

Daikin

In stock
Model

DSH1023D000001S

ID

190760

Was $11,385.00 Your Low Price Special Price $9,500.00
Ships in 5-7 Business Days
 
Product Features
  • Designed for Easy Retrofit Installs
  • Custom Roof Curbs designed to fit your current adapter!
  • Precharged with R32 Refrigerant
  • Single Stage Condenser
  • 208/230V 3 Phase
  • Up to a 5 Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

Efficient 8.5-Ton Packaged Heat Pump for Light Commercial Applications with Single-Stage Cooling

The Daikin DSH1023D000001S is an 8.5-ton commercial packaged heat pump designed to provide reliable heating and cooling for light commercial applications. Combining 100,000 BTU/h of nominal cooling capacity and 100,000 BTU/h of nominal heating capacity at 47°F with direct-drive air distribution, this all-in-one rooftop system helps deliver efficient, dependable comfort while simplifying equipment placement and preserving valuable indoor space.

Key Benefits

  • 15.5 IEER / 11.4 EER Efficiency – Provides efficient commercial cooling performance to help manage energy consumption during varying load conditions.
  • 100,000 BTU/h Cooling Capacity – Provides substantial cooling capacity for light commercial spaces requiring dependable packaged rooftop comfort.
  • Single-Stage Cooling with Scroll Compressors – Provides staged cooling operation to better match changing building demand and support efficient part-load performance.
  • Direct-Drive Supply Fan – Provides dependable air distribution without belts and sheaves associated with traditional belt-driven fan systems.
  • Packaged Rooftop Configuration – Combines the major heating, cooling, air distribution, filtration, and control components into a single outdoor unit to simplify equipment placement.
  • R-32 Refrigerant – Uses R-32 refrigerant in the packaged heat pump system.
  • 208/230-Volt, Three-Phase Operation – Provides compatibility with common commercial 208/230-volt, three-phase electrical service.
  • Tool-Less Filter Access – Provides convenient access for routine filter replacement and maintenance.

R-32 Single-Stage Packaged Heat Pump – Primary Heating & Cooling Benefit

The integrated heat pump system provides 100,000 BTU/h of nominal cooling capacity and 100,000 BTU/h of nominal heating capacity at 47°F to help maintain comfortable indoor temperatures during both cooling and heating operation. The DSH1023D000001S uses R-32 refrigerant and two scroll compressors with single-stage cooling operation in a direct-drive packaged rooftop configuration.

8.5-Ton Cooling Performance

The cooling system provides 100,000 BTU/h of nominal cooling capacity with a 15.5 IEER rating and 11.4 EER rating. Single-stage cooling operation helps provide efficient commercial cooling performance across changing load conditions while supporting dependable indoor comfort.

Efficient R-32 Operation

With a 15.5 IEER rating and 11.4 EER rating, this system is designed for efficient and reliable cooling operation. The unit uses R-32 refrigerant, two scroll compressors, and a direct-drive indoor blower to support dependable heat transfer and air distribution. The evaporator uses a round-tube plate-fin coil with a 15 ft² face area, three rows deep, and 16 fins per inch. The condenser uses a round-tube plate-fin coil with a 33.4 ft² face area, two rows deep, and 16 fins per inch.

Packaged Rooftop Installation Design

The packaged rooftop configuration combines the compressors, coils, supply fan, controls, filtration, heating components, and air distribution components into a single outdoor unit, helping simplify equipment placement and preserve valuable indoor space. The DSH1023D000001S measures approximately 93¾ inches wide by 60⅜ inches deep by 54⅝ inches high and has a shipping weight of approximately 1,229 pounds. The direct-drive indoor blower provides 3,000 CFM of nominal airflow with standard external static pressure operation. The convertible airflow orientation allows the unit to serve downflow or horizontal applications, and the equipment is designed as a direct replacement for most rooftop units without requiring a curb adapter.

Controls & Comfort

The DSH1023D000001S uses a 24-volt electromechanical controls package for connection to compatible commercial thermostats and control systems. The direct-drive indoor blower uses a 15 x 12-inch wheel, provides 3,000 CFM of nominal airflow, and operates from approximately 300 to 1,600 RPM. The unit uses two 20 x 25 x 2-inch filters and two 25 x 25 x 2-inch filters. Compatible economizer, ventilation, damper, power exhaust, electric heat, and control accessories can be selected to meet application-specific comfort and outdoor-air requirements.

Light Commercial Applications

The Daikin DSH1023D000001S is designed for light commercial applications where a high-efficiency packaged rooftop heat pump can provide centralized heating and cooling. Its 8.5-ton capacity, single-stage cooling operation, R-32 refrigerant, direct-drive supply fan, and 208/230-volt three-phase electrical configuration make it well suited for commercial retrofit and new installation projects.

Service & Maintenance

The unit is designed for straightforward service and maintenance, with easy accessibility and tool-less filter access for routine filter replacement. Screw-on style pressure switches are designed for ease of replacement, while the direct-drive supply fan eliminates belt and sheave maintenance associated with belt-driven systems. The packaged configuration keeps the major heating, cooling, air distribution, and control components within a single outdoor enclosure. The unit is AHRI Certified and ETL Listed.

Warranty

The Daikin DSH1023D000001S includes a 5-year parts limited warranty. Complete warranty details, terms, conditions, registration requirements, and applicable limitations are provided in Daikin’s official warranty documentation.

Recommended Accessories

Efficient Commercial Comfort with the Daikin DSH1023D000001S

Experience efficient commercial heating and cooling with the Daikin DSH1023D000001S. Combining 100,000 BTU/h of cooling capacity, 15.5 IEER efficiency, single-stage cooling, R-32 refrigerant, 208/230-volt three-phase operation, and direct-drive air distribution in one packaged rooftop heat pump system.

Packaged Unit Buyers Guide

  • How packaged units work for residential and commercial use
  • The different types of packaged units
  • Figuring out the right size unit for your needs
  • The importance of a custom curb adapter
  • And much more!
More Information
Daikin 8.5 Ton 11.4 EER Light Commercial Packaged Heat Pump | 208/230V 3 Phase - R32 - Single Stage
FeatureSpec
SKUDSH1023D000001S
Refrigerant ChargePre-charged
Weight (in lbs)1157
Brand/ManufacturerDaikin
ReplacesDFH1023D000001S
UPC633190263698
Additional InformationUses two 20" x 25" x 2" and two 25" x 25" x 2" filters
Cooling BTU98,000 BTU
Heating BTU97,000 BTU
Drive TypeDirect
Maximum CFM3000
Decibel Level (dBA)83.7 decibels
Motor RPM300-1600
HorsepowerIndoor: 2.4, Outdoor: 1/3
RefrigerantR32
EER11.4
IEER15.5
Condenser StagesSingle Stage
Compressor TypeScroll
Electrical208 / 230 V. 3 Phase 60 Hz
PhaseThree Phase
Max Breaker Size50/50 amps
Min. Breaker Size43.7/43.7 amps
Tonnage8.5 Ton
Height54 5/8"
Width93 3/4"
Depth60 3/8"
Warranty20 Years Heat Exchanger, 5 Years Parts with Online Registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Daikin 8.5 Ton 11.4 EER Light Commercial Packaged Heat Pump | 208/230V 3 Phase - R32 - Single Stage
Your Rating
Customer Questions
What does BTU and Tonnage Mean?
BTU (British Thermal Unit) measures the amount of heating or cooling energy a commercial rooftop packaged unit can produce per hour, while tonnage measures the unit's nominal cooling capacity. One ton of cooling equals 12,000 BTU/h, meaning a 10-ton commercial rooftop unit provides approximately 120,000 BTU/h of cooling capacity. Both measurements help contractors and customers determine the appropriate HVAC system size and output for a building's heating and cooling requirements.
What accessories or additional components are needed to install a Commercial Rooftop Units?
Installing a commercial rooftop unit may require several accessories and additional components depending on the building's existing setup and installation requirements. Common components include a roof curb or curb adapter, ductwork transitions, electrical disconnects, thermostats, economizers, dampers, and supplemental heating kits when applicable. Additional accessories, such as hail guards, smoke detectors, and condensate drain components, may also be recommended based on the application. Always verify equipment compatibility and manufacturer installation requirements before purchasing additional components.
Can I replace my existing Commercial Rooftop Unit without replacing the ductwork?
Yes. In many cases, an existing commercial rooftop unit can be replaced without replacing the current ductwork, provided the duct system is in good condition and compatible with the new equipment. Before installation, an HVAC professional should evaluate the ductwork, airflow requirements, unit capacity, and existing connections to ensure proper system performance. Additional modifications may be necessary if the new unit has different dimensions, airflow configurations, or connection requirements.
What is the difference between EER and IEER ratings on Commercial Rooftop Units?
EER (Energy Efficiency Ratio) and IEER (Integrated Energy Efficiency Ratio) are ratings used to measure the cooling efficiency of commercial HVAC equipment. EER measures how efficiently a unit operates under specific full-load outdoor temperature and operating conditions, while IEER evaluates efficiency across multiple operating conditions, including part-load performance. IEER provides a broader picture of how efficiently a commercial rooftop unit operates under varying cooling demands throughout the year. Higher EER and IEER ratings generally indicate greater energy efficiency and potentially lower operating costs.
What are the different types of Commercial Rooftop HVAC Units?
Commercial rooftop HVAC units are available in several configurations designed to meet different building heating and cooling requirements. The most common types include cooling-only air conditioner units, gas/electric packaged units, heat pump units, and dual-fuel units. These systems combine major HVAC components into a single outdoor cabinet, providing centralized temperature control for commercial spaces. The best option depends on the building's heating and cooling needs, energy requirements, and installation specifications.
How does a Commercial Rooftop Heat Pump Unit work?
A commercial rooftop heat pump works by transferring heat between the indoor and outdoor environments to provide both heating and cooling. During warmer months, the system removes heat from indoor air and transfers it outside to cool the building. During colder months, the refrigeration cycle reverses, extracting heat from outdoor air and transferring it indoors to provide warmth. This allows a single packaged rooftop unit to deliver year-round temperature control without relying on a traditional gas furnace.
How well do Commercial Rooftop Heat Pumps work in freezing temperatures?
Commercial rooftop heat pumps can provide heating in freezing temperatures by extracting available heat from outdoor air and transferring it indoors. However, heating capacity and efficiency generally decrease as outdoor temperatures drop, and performance varies depending on the unit's design and operating temperature range. Many commercial rooftop heat pumps include supplemental electric heat to maintain indoor comfort during extremely cold conditions. Always check the manufacturer's published low-ambient operating limits and heating performance specifications when selecting a unit for colder climates.
Does a Commercial Heat Pump require supplemental electric heat?
A commercial rooftop heat pump does not always require supplemental electric heat, but it can be beneficial in colder climates or during periods of extremely low outdoor temperatures. As temperatures drop, a heat pump's heating capacity and efficiency typically decrease, making supplemental electric heat useful for maintaining comfortable indoor temperatures when the system cannot meet the building's heating demand on its own. Whether supplemental heat is necessary depends on the unit's heating capacity, operating temperature range, building requirements, and local climate.
What is a good efficiency rating for a Commercial Rooftop Heat Pump?
A good efficiency rating for a commercial rooftop heat pump depends on the unit's size, application, and operating requirements. When comparing models, look at SEER2 and EER2 ratings for cooling efficiency and COP (Coefficient of Performance) or heating performance ratings for heating efficiency. Higher ratings generally indicate better energy efficiency and lower operating costs. IEER is also an important rating to consider for commercial rooftop equipment because it measures cooling efficiency under varying operating conditions and part-load capacities. Always compare ratings within the same equipment category and capacity range when selecting a commercial rooftop heat pump.
What types of Commercial buildings benefit most from Rooftop Heat Pump Units?
Commercial rooftop heat pump units are ideal for buildings that require reliable year-round heating and cooling, including offices, retail stores, restaurants, schools, warehouses, and light industrial facilities. They are especially beneficial for businesses looking for an energy-efficient, all-electric HVAC solution that provides both heating and cooling in one self-contained system. Rooftop heat pumps can also help free up indoor space by housing major HVAC components outside the building.
Did you find what you were looking for?
blockboard tech