Daikin 8.5 Ton 11.4 EER Light Commercial Packaged Heat Pump | 460V 3 Phase - R32 - Single Stage

SAVE $1,500.00
By

Daikin

In stock
Model

DSH1024D000001S

ID

190761

Was $11,500.00 Your Low Price Special Price $10,000.00
Ships in 5-7 Business Days
 
Product Features
  • Designed for Easy Retrofit Installs
  • Custom Roof Curbs designed to fit your current adapter!
  • Precharged with R32 Refrigerant
  • Single Stage Condenser
  • 460V 3 Phase
  • Up to a 5 Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

Reliable Heat Pump Comfort for Light Commercial Buildings with R-32 Direct-Drive Performance

The Daikin DSH1024D000001S is an 8.5-ton commercial heat pump packaged unit designed to provide reliable year-round heating and cooling for light commercial applications. Combining 97,000 BTU/h of heat pump heating capacity at 47°F with 98,000 BTU/h of cooling capacity, this all-in-one rooftop system helps deliver dependable comfort while simplifying installation and preserving valuable indoor space.

Key Benefits

  • 15.5 IEER / 11.4 EER Efficiency – Helps provide efficient cooling performance during both part-load and full-load commercial operation.
  • Heat Pump Heating – Provides 97,000 BTU/h of heating capacity at 47°F with a COP of 3.4 at 47°F to support dependable year-round comfort.
  • 98,000 BTU/h Cooling Capacity – Provides reliable cooling performance for light commercial spaces.
  • 460V Three-Phase Electrical Configuration – Provides a 460/3/60 electrical configuration for compatible commercial installations.
  • Convertible Airflow Orientation – Supports downflow or horizontal applications for greater installation flexibility.
  • R-32 Refrigerant – Uses R-32 refrigerant in a standard-efficiency packaged rooftop system.
  • Direct-Drive Supply Fan – Provides efficient airflow control without the belts, sheaves, bearings, and lubrication associated with belt-driven systems.
  • Service-Friendly Construction – Easy-access controls and a draw-through filter section help simplify routine service and maintenance.

R-32 Heat Pump Heating Performance

The integrated heat pump heating system provides 97,000 BTU/h of heating capacity to help maintain comfortable indoor temperatures during colder-weather operation. The evaporator coil, condenser coil, compressors, and refrigerant circuit are designed for heat pump operation. Electric heat options are available for supplemental heating requirements.

98,000 BTU/h Cooling Performance

The heat pump cooling system provides 98,000 BTU/h of cooling capacity with a 15.5 IEER and 11.4 EER efficiency rating. Two high-performance, low-noise scroll compressors are designed to match the required total load and provide dependable cooling performance during varying commercial load conditions.

High-Efficiency R-32 Performance

With a 15.5 IEER rating and 11.4 EER rating, this system is designed to provide efficient commercial cooling performance. The R-32 refrigerant system combines with a direct-drive supply fan and large-face-area outdoor coil constructed with seamless copper tubes mechanically bonded into aluminum plate-type fins to support efficient, reliable packaged rooftop operation.

Rooftop & Installation Design

The packaged rooftop configuration combines the heat pump, compressors, coils, supply fan, controls, and other major HVAC components into a single outdoor unit, helping simplify equipment placement and preserve valuable indoor space. Daikin packaged rooftop units are designed for fast and easy installation and are ideal for both new construction and retrofit projects. The units are built to be a direct replacement for most rooftop units in the field without the need for a curb adapter. Convertible airflow orientation allows the unit to serve downflow or horizontal applications.

Controls & Comfort

The DSH1024D000001S features a well-organized, large, easy-to-use weatherproof internal control box with easy access. Its direct-drive supply fan provides efficient airflow control, while the heat pump and available electric heat options support dependable packaged heating and cooling operation. The unit is completely wired and tested at the factory to help provide faster commissioning and start-up.

Light Commercial Applications

The Daikin DSH1024D000001S is designed for light commercial rooftop applications requiring packaged heating and cooling. Its 8.5-ton capacity, 460V three-phase electrical configuration, R-32 refrigerant, direct-drive supply fan, and convertible airflow orientation make it well suited for compatible commercial buildings and retrofit installations.

Service & Maintenance

The unit is designed with serviceability in mind, featuring easy accessibility through its weatherproof internal control box and draw-through filter section. Screw-on-style pressure switches are designed for ease of replacement, while the direct-drive indoor fan eliminates the belts, sheaves, bearings, and lubrication associated with belt-driven systems. The unit's factory-wired and tested configuration also helps simplify commissioning and start-up.

Warranty

The Daikin DSH1024D000001S includes a 5-Year Parts Limited Warranty. Complete warranty details, including applicable terms, conditions, and requirements, are provided in the Daikin warranty documentation.

Recommended Accessories

Reliable Year-Round Comfort with the Daikin DSH1024D000001S

Experience reliable commercial heating and cooling with the Daikin DSH1024D000001S. Combining 97,000 BTU/h heat pump heating capacity and 98,000 BTU/h cooling capacity in one R-32 direct-drive packaged rooftop system.

Packaged Unit Buyers Guide

  • How packaged units work for residential and commercial use
  • The different types of packaged units
  • Figuring out the right size unit for your needs
  • The importance of a custom curb adapter
  • And much more!
More Information
Daikin 8.5 Ton 11.4 EER Light Commercial Packaged Heat Pump | 460V 3 Phase - R32 - Single Stage
FeatureSpec
SKUDSH1024D000001S
Refrigerant ChargePre-charged
Weight (in lbs)1157
Brand/ManufacturerDaikin
ReplacesDFH1024D000001S
UPC633190263704
Additional InformationUses two 20" x 25" x 2" and two 25" x 25" x 2" filters
Cooling BTU98,000 BTU
Heating BTU97,000 BTU
Drive TypeDirect
Maximum CFM3000
Decibel Level (dBA)83.7 decibels
Motor RPM300-1600
HorsepowerIndoor: 2.4, Outdoor: 1/3
RefrigerantR32
EER11.4
IEER15.5
Condenser StagesSingle Stage
Compressor TypeScroll
Electrical460 V. 3 Phase 60 Hz
PhaseThree Phase
Max Breaker Size25 amps
Min. Breaker Size21.5 amps
Tonnage8.5 Ton
Height54 5/8"
Width93 3/4"
Depth60 3/8"
Warranty20 Years Heat Exchanger, 5 Years Parts with Online Registration
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Daikin 8.5 Ton 11.4 EER Light Commercial Packaged Heat Pump | 460V 3 Phase - R32 - Single Stage
Your Rating
Customer Questions
What does BTU and Tonnage Mean?
BTU (British Thermal Unit) measures the amount of heating or cooling energy a commercial rooftop packaged unit can produce per hour, while tonnage measures the unit's nominal cooling capacity. One ton of cooling equals 12,000 BTU/h, meaning a 10-ton commercial rooftop unit provides approximately 120,000 BTU/h of cooling capacity. Both measurements help contractors and customers determine the appropriate HVAC system size and output for a building's heating and cooling requirements.
What accessories or additional components are needed to install a Commercial Rooftop Units?
Installing a commercial rooftop unit may require several accessories and additional components depending on the building's existing setup and installation requirements. Common components include a roof curb or curb adapter, ductwork transitions, electrical disconnects, thermostats, economizers, dampers, and supplemental heating kits when applicable. Additional accessories, such as hail guards, smoke detectors, and condensate drain components, may also be recommended based on the application. Always verify equipment compatibility and manufacturer installation requirements before purchasing additional components.
Can I replace my existing Commercial Rooftop Unit without replacing the ductwork?
Yes. In many cases, an existing commercial rooftop unit can be replaced without replacing the current ductwork, provided the duct system is in good condition and compatible with the new equipment. Before installation, an HVAC professional should evaluate the ductwork, airflow requirements, unit capacity, and existing connections to ensure proper system performance. Additional modifications may be necessary if the new unit has different dimensions, airflow configurations, or connection requirements.
What is the difference between EER and IEER ratings on Commercial Rooftop Units?
EER (Energy Efficiency Ratio) and IEER (Integrated Energy Efficiency Ratio) are ratings used to measure the cooling efficiency of commercial HVAC equipment. EER measures how efficiently a unit operates under specific full-load outdoor temperature and operating conditions, while IEER evaluates efficiency across multiple operating conditions, including part-load performance. IEER provides a broader picture of how efficiently a commercial rooftop unit operates under varying cooling demands throughout the year. Higher EER and IEER ratings generally indicate greater energy efficiency and potentially lower operating costs.
What are the different types of Commercial Rooftop HVAC Units?
Commercial rooftop HVAC units are available in several configurations designed to meet different building heating and cooling requirements. The most common types include cooling-only air conditioner units, gas/electric packaged units, heat pump units, and dual-fuel units. These systems combine major HVAC components into a single outdoor cabinet, providing centralized temperature control for commercial spaces. The best option depends on the building's heating and cooling needs, energy requirements, and installation specifications.
How does a Commercial Rooftop Heat Pump Unit work?
A commercial rooftop heat pump works by transferring heat between the indoor and outdoor environments to provide both heating and cooling. During warmer months, the system removes heat from indoor air and transfers it outside to cool the building. During colder months, the refrigeration cycle reverses, extracting heat from outdoor air and transferring it indoors to provide warmth. This allows a single packaged rooftop unit to deliver year-round temperature control without relying on a traditional gas furnace.
How well do Commercial Rooftop Heat Pumps work in freezing temperatures?
Commercial rooftop heat pumps can provide heating in freezing temperatures by extracting available heat from outdoor air and transferring it indoors. However, heating capacity and efficiency generally decrease as outdoor temperatures drop, and performance varies depending on the unit's design and operating temperature range. Many commercial rooftop heat pumps include supplemental electric heat to maintain indoor comfort during extremely cold conditions. Always check the manufacturer's published low-ambient operating limits and heating performance specifications when selecting a unit for colder climates.
Does a Commercial Heat Pump require supplemental electric heat?
A commercial rooftop heat pump does not always require supplemental electric heat, but it can be beneficial in colder climates or during periods of extremely low outdoor temperatures. As temperatures drop, a heat pump's heating capacity and efficiency typically decrease, making supplemental electric heat useful for maintaining comfortable indoor temperatures when the system cannot meet the building's heating demand on its own. Whether supplemental heat is necessary depends on the unit's heating capacity, operating temperature range, building requirements, and local climate.
What is a good efficiency rating for a Commercial Rooftop Heat Pump?
A good efficiency rating for a commercial rooftop heat pump depends on the unit's size, application, and operating requirements. When comparing models, look at SEER2 and EER2 ratings for cooling efficiency and COP (Coefficient of Performance) or heating performance ratings for heating efficiency. Higher ratings generally indicate better energy efficiency and lower operating costs. IEER is also an important rating to consider for commercial rooftop equipment because it measures cooling efficiency under varying operating conditions and part-load capacities. Always compare ratings within the same equipment category and capacity range when selecting a commercial rooftop heat pump.
What types of Commercial buildings benefit most from Rooftop Heat Pump Units?
Commercial rooftop heat pump units are ideal for buildings that require reliable year-round heating and cooling, including offices, retail stores, restaurants, schools, warehouses, and light industrial facilities. They are especially beneficial for businesses looking for an energy-efficient, all-electric HVAC solution that provides both heating and cooling in one self-contained system. Rooftop heat pumps can also help free up indoor space by housing major HVAC components outside the building.
Did you find what you were looking for?
blockboard tech