Trane 5 Ton 13.4 SEER2 Commercial Packaged Heat Pump Precedent Series | 208/230V 3 Phase - R454B - Single Stage

By

Trane

In stock
Model

WSK060A3S

ID

205102

$9,145.00
Out of Stock
Free Shipping
 
Product Features
  • Designed for Easy Retrofit Installs
  • Custom Roof Curbs designed to fit your current adapter!
  • Precharged with R454b Refrigerant
  • Single Stage Condenser
  • 208/230V 3 Phase
  • Up to a 5 Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

Year-Round Comfort 5-Ton Packaged Heat Pump for Light Commercial Buildings with R-454B Refrigerant

The Trane Precedent WSK060A3S is a 5-ton commercial heat pump packaged unit designed to provide dependable heating and cooling for light commercial applications. Combining all-electric heat pump heating with packaged cooling in a single rooftop system, this all-in-one unit helps deliver reliable year-round comfort while simplifying equipment placement and service. The WSK060A3S uses R-454B refrigerant and operates with a 208/230V, three-phase electrical supply.

Key Benefits

  • 13.4 SEER2 Cooling Efficiency – Provides efficient cooling performance for commercial spaces while supporting responsible energy use.
  • All-Electric Heat Pump Heating – Provides electric heating without the need for a conventional gas heating system.
  • 5-Ton Cooling Capacity – Provides packaged cooling performance for light commercial applications.
  • Packaged Rooftop Design – Combines major heating, cooling, and air-handling components into one outdoor unit to simplify equipment placement.
  • Convertible Airflow Configuration – Provides installation flexibility for different commercial building requirements.
  • Direct-Drive Fan – Helps improve efficiency while eliminating fan belts that require replacement.
  • Symbio® 700 Controls – Provides advanced equipment control, monitoring, configuration, and service capabilities.
  • Service-Friendly Design – Hinged control-panel access, tool-less coil guards, and the Symbio Service & Installation app help simplify maintenance and servicing.

All-Electric Heat Pump Heating

The integrated all-electric heat pump system provides heating for year-round comfort without conventional gas heat. The Precedent heat pump platform is available with optional auxiliary electric resistance heat, while the Symbio® 700 controller supports advanced equipment control and configuration. The system uses low-GWP R-454B refrigerant with factory-installed refrigerant leak detection systems where required.

13.4 SEER2 Cooling Performance

The packaged heat pump cooling system provides a nominal 5-ton class of cooling capacity with a 13.4 SEER2 efficiency rating for the WSK060A3S configuration. This helps provide dependable cooling performance while supporting efficient warm-weather operation in light commercial applications.

Standard-Efficiency Packaged Heat Pump Design

With a 13.4 SEER2 cooling efficiency rating and single-stage condenser operation, the WSK060A3S is designed to provide dependable packaged heating and cooling for commercial spaces. The all-electric heat pump configuration provides an alternative to conventional gas heating, while the Precedent platform offers efficiency options and controls designed for commercial comfort and building operation.

Rooftop Packaged Installation Design

The packaged rooftop configuration combines the heat pump, cooling, air-moving, and control components into a single outdoor unit, helping simplify equipment placement and preserve valuable indoor space. The Precedent platform features convertible airflow configuration for installation flexibility, while direct-drive fans eliminate fan belts that would otherwise require replacement. The packaged design is available for commercial rooftop applications and replacement projects.

Symbio® 700 Controls & Comfort

The WSK060A3S uses the Symbio® 700 controller for advanced equipment control. The controller includes a 2-inch by 16-inch LCD onboard display and supports the Symbio Service & Installation app for configuration, setup, status updates, alarms, and service capabilities. Precedent heat pump units support single-zone and true multiple-zone VAV capabilities, with control options including expansion modules, BACnet®, Modbus™, Air-Fi® wireless communication, and BAS points for refrigerant leak detection.

Commercial Applications

The Trane Precedent WSK060A3S is designed for light commercial rooftop applications where packaged electric heating and cooling are required. Its 5-ton capacity, convertible airflow configuration, all-electric heat pump operation, and commercial control capabilities make it suitable for a range of commercial buildings and replacement projects.

Service & Maintenance

The Precedent platform is designed to simplify service with hinged control-panel access, direct-drive fans that eliminate fan-belt replacement, and tool-less coil guards that simplify maintenance while providing additional coil protection. The Symbio Service & Installation app provides technicians with advanced configuration, setup, status, alarm, and service capabilities.

Warranty

The Trane Precedent heat pump platform includes a 3-year warranty on parts, coils, and controls and a 5-year warranty on compressors. Warranty coverage is subject to Trane's applicable warranty terms and conditions.

Recommended Accessories

  • Symbio® 700 Control Options – Expansion modules, BACnet®, Modbus™, and Air-Fi® wireless communication options are available for compatible control and building automation requirements.
  • Economizer – Low-leak economizer options are available for compatible configurations requiring additional ventilation and free-cooling capabilities.
  • Filtration – Filtration options are available up to MERV 13 for compatible configurations.
  • Condenser Coil Protection – CompleteCoat™ condenser coil protection is available as an option for compatible configurations.
  • Smoke Detection – Supply and return smoke detector options are available for compatible configurations.

Reliable Year-Round Comfort with the Trane Precedent WSK060A3S

Experience dependable commercial comfort with the Trane Precedent WSK060A3S. Combining all-electric heat pump heating and efficient packaged cooling in one rooftop system, the 5-ton unit uses R-454B refrigerant and Symbio® 700 controls to provide a flexible solution for light commercial heating and cooling applications.

More Information
Trane 5 Ton 13.4 SEER2 Commercial Packaged Heat Pump Precedent Series | 208/230V 3 Phase - R454B - Single Stage
FeatureSpec
SKUWSK060A3S
Weight (in lbs)706
Brand/ManufacturerTrane
Cooling BTU58,500 BTU
Heating BTU51,000 BTU
Drive TypeDirect
Maximum CFM2000
Decibel Level (dBA)82
Motor RPMOutdoor: 1100 / Indoor: 1400
HorsepowerOutdoor: 0.33 / Indoor: 1.0
RefrigerantR454B
SEER2 (Efficiency)13.4
EER211
Condenser StagesSingle Stage
Compressor TypeScroll
Electrical208/230v 3 Phase 60 Hz
PhaseThree Phase
Max Breaker Size45 Amps
Min. Breaker Size29 Amps
Tonnage5 Ton
Height50 7/8"
Width63 1/8"
Depth99 5/8"
Warranty3 year Limited Parts Warranty, 5 year Limited Compressor Warranty
Resources
Safety InformationPROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:Trane 5 Ton 13.4 SEER2 Commercial Packaged Heat Pump Precedent Series | 208/230V 3 Phase - R454B - Single Stage
Your Rating
Customer Questions
What does BTU and Tonnage Mean?
BTU (British Thermal Unit) measures the amount of heating or cooling energy a commercial rooftop packaged unit can produce per hour, while tonnage measures the unit's nominal cooling capacity. One ton of cooling equals 12,000 BTU/h, meaning a 10-ton commercial rooftop unit provides approximately 120,000 BTU/h of cooling capacity. Both measurements help contractors and customers determine the appropriate HVAC system size and output for a building's heating and cooling requirements.
What accessories or additional components are needed to install a Commercial Rooftop Units?
Installing a commercial rooftop unit may require several accessories and additional components depending on the building's existing setup and installation requirements. Common components include a roof curb or curb adapter, ductwork transitions, electrical disconnects, thermostats, economizers, dampers, and supplemental heating kits when applicable. Additional accessories, such as hail guards, smoke detectors, and condensate drain components, may also be recommended based on the application. Always verify equipment compatibility and manufacturer installation requirements before purchasing additional components.
Can I replace my existing Commercial Rooftop Unit without replacing the ductwork?
Yes. In many cases, an existing commercial rooftop unit can be replaced without replacing the current ductwork, provided the duct system is in good condition and compatible with the new equipment. Before installation, an HVAC professional should evaluate the ductwork, airflow requirements, unit capacity, and existing connections to ensure proper system performance. Additional modifications may be necessary if the new unit has different dimensions, airflow configurations, or connection requirements.
What is the difference between EER and IEER ratings on Commercial Rooftop Units?
EER (Energy Efficiency Ratio) and IEER (Integrated Energy Efficiency Ratio) are ratings used to measure the cooling efficiency of commercial HVAC equipment. EER measures how efficiently a unit operates under specific full-load outdoor temperature and operating conditions, while IEER evaluates efficiency across multiple operating conditions, including part-load performance. IEER provides a broader picture of how efficiently a commercial rooftop unit operates under varying cooling demands throughout the year. Higher EER and IEER ratings generally indicate greater energy efficiency and potentially lower operating costs.
What are the different types of Commercial Rooftop HVAC Units?
Commercial rooftop HVAC units are available in several configurations designed to meet different building heating and cooling requirements. The most common types include cooling-only air conditioner units, gas/electric packaged units, heat pump units, and dual-fuel units. These systems combine major HVAC components into a single outdoor cabinet, providing centralized temperature control for commercial spaces. The best option depends on the building's heating and cooling needs, energy requirements, and installation specifications.
How does a Commercial Rooftop Heat Pump Unit work?
A commercial rooftop heat pump works by transferring heat between the indoor and outdoor environments to provide both heating and cooling. During warmer months, the system removes heat from indoor air and transfers it outside to cool the building. During colder months, the refrigeration cycle reverses, extracting heat from outdoor air and transferring it indoors to provide warmth. This allows a single packaged rooftop unit to deliver year-round temperature control without relying on a traditional gas furnace.
How well do Commercial Rooftop Heat Pumps work in freezing temperatures?
Commercial rooftop heat pumps can provide heating in freezing temperatures by extracting available heat from outdoor air and transferring it indoors. However, heating capacity and efficiency generally decrease as outdoor temperatures drop, and performance varies depending on the unit's design and operating temperature range. Many commercial rooftop heat pumps include supplemental electric heat to maintain indoor comfort during extremely cold conditions. Always check the manufacturer's published low-ambient operating limits and heating performance specifications when selecting a unit for colder climates.
Does a Commercial Heat Pump require supplemental electric heat?
A commercial rooftop heat pump does not always require supplemental electric heat, but it can be beneficial in colder climates or during periods of extremely low outdoor temperatures. As temperatures drop, a heat pump's heating capacity and efficiency typically decrease, making supplemental electric heat useful for maintaining comfortable indoor temperatures when the system cannot meet the building's heating demand on its own. Whether supplemental heat is necessary depends on the unit's heating capacity, operating temperature range, building requirements, and local climate.
What is a good efficiency rating for a Commercial Rooftop Heat Pump?
A good efficiency rating for a commercial rooftop heat pump depends on the unit's size, application, and operating requirements. When comparing models, look at SEER2 and EER2 ratings for cooling efficiency and COP (Coefficient of Performance) or heating performance ratings for heating efficiency. Higher ratings generally indicate better energy efficiency and lower operating costs. IEER is also an important rating to consider for commercial rooftop equipment because it measures cooling efficiency under varying operating conditions and part-load capacities. Always compare ratings within the same equipment category and capacity range when selecting a commercial rooftop heat pump.
What types of Commercial buildings benefit most from Rooftop Heat Pump Units?
Commercial rooftop heat pump units are ideal for buildings that require reliable year-round heating and cooling, including offices, retail stores, restaurants, schools, warehouses, and light industrial facilities. They are especially beneficial for businesses looking for an energy-efficient, all-electric HVAC solution that provides both heating and cooling in one self-contained system. Rooftop heat pumps can also help free up indoor space by housing major HVAC components outside the building.
Did you find what you were looking for?
Why Choose a Trane?
Why Choose Trane?

For years, Trane has been committed to delivering reliable, high-quality, and affordable heating and cooling solutions. Backed by Trane’s legacy of engineering excellence, RunTru products are designed and built to provide dependable indoor comfort for homeowners. With a focus on durability and performance, Trane has earned the trust of HVAC professionals across North America, offering practical and cost-effective solutions without compromising on quality. Shop all Trane products.