The ACIQ Extreme series is equipped with Extreme Heat technology, allowing continuous heating even in frigid temperatures as low as -22 degrees outside. Enjoy optimal efficiency with high SEER and high HSPF ratings, whether you need cooling or heating for your space.
Please note that this model of equipment does not have quick connect line set connectors and is not a DIY unit. Installation materials such as line sets, control wire, drain hose, whip and disconnect are not included, but are available at additional cost in the Accessories section on this page. You will need a professional to add more refrigerant and vacuum the lines as needed. The automated cleaning function will clean your system, but it is recommended to periodically clean the unit's filters manually.
Concealed Duct air handlers give you all the advantages of a multi zone mini split, without any visible air handlers on your walls or ceilings. These flexible units are designed to be concealed above the ceiling, below the floor, above a closet ceiling, above a hallway ceiling or behind a soffit. You run flex ducting from the concealed duct air handler to ceiling or wall registers in your desired location. Depending on the capacity of the unit, up to 4 flex duct runs can be connected, perfect for a pair of small bedrooms or a master suite.
The design is extremely simple return air is brought in at the rear of the unit and supply (cooled or heated) air is pushed out the front by an almost-silent squirrel cage fan. You attach a pre-made manifold takeoff or field-fabricate plenums using ductboard. Using readily available supplies, the customization possibilities are endless.
Concealed duct system installations require a certain amount of pre-planning, and are similar in scope to a standard home HVAC installation. They are best used in new construction projects or additions. Installation will require flex ducting, register vents, plenums and installation supplies in addition to the equipment components. The Concealed Duct units have a factory-installed pump to lift the condensation. From there you will use PVC to construct a drain system to a safe wastewater location.
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 1/2 inch O.D. flared ends, length 35 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 1/2 inch O.D. flared ends, length 25 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 1/2 inch O.D. flared ends, length 50 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 1/2 inch O.D. flared ends, length 30 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.
Features:
Refrigerant line set (pair) for mini split systems, liquid line size 1/4 inch O.D. flared ends, suction line size 1/2 inch O.D. flared ends, length 15 feet, insulation thickness of 1/2 inch. For use with air conditioning and refrigeration systems, includes both the liquid line and the suction line.