ACIQ 6 Ton 150,000 BTU 13.4 SEER2 Commercial Gas Packaged Unit - High Heat | 460V 3 Phase - R454B - Two Stage

ACIQ 6 Ton 150,000 BTU 13.4 SEER2 Commercial Gas Packaged Unit - High Heat | 460V 3 Phase - R454B - Two Stage
ONLY 3 LEFT!
Free Shipping
By

ACiQ

In stock
Model

RGF072LE2A0AAA

ID

197086

Was $9,688.00 Your Low Price Special Price $7,750.00
 
Product Features
  • Designed for Easy Retrofit Installs
  • Custom Roof Curbs designed to fit your current adapter!
  • Precharged with R454b Refrigerant
  • 2-Stage Condenser
  • 460V 3 Phase
  • Up to a 10-Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

Efficient 6-Ton Two-Stage Gas/Electric Packaged Rooftop Unit for Light Commercial Applications with X-Vane™ Fan Technology

The ACiQ RGF072LE2A0AAA is a 6-ton commercial gas/electric packaged rooftop unit designed for light commercial heating and cooling applications. The RGF036-072 platform combines gas heating and electric cooling with two-stage operation, direct-drive ECM/Vane Axial X-Vane™ fan technology, and a packaged rooftop configuration for dependable year-round comfort. The RGF platform is designed with current-generation efficiency and service features for light commercial applications.

Key Benefits

  • 13.4 SEER2 / 11.5 EER2 / 15.5 IEER – Provides efficient seasonal, full-load, and integrated part-load cooling performance for the 6-ton RGF platform.
  • Two-Stage Heating – Provides staged gas-heating operation to help match heating output to changing commercial load requirements.
  • Two-Stage Cooling – Provides staged cooling operation for improved capacity matching and comfort.
  • Direct-Drive X-Vane™ Fan – Uses direct-drive ECM/Vane Axial technology without the conventional belt-driven fan arrangement.
  • Two-Speed Indoor Fan – Supports staged system operation while providing appropriate indoor airflow for changing load conditions.
  • 460V Three-Phase Electrical Configuration – The L electrical designation identifies 460V, three-phase, 60 Hz service.
  • Convertible Airflow Design – Provides installation flexibility for compatible rooftop applications.
  • Multiple Coil Options – Manufacturer-listed coil configurations include aluminum/copper, copper/copper, precoated, and E-coated options.

Medium-Heat Gas Heating

The E heating designation identifies the medium-heat configuration. The RGF036-072 platform provides three heat options—low, medium, and high—allowing the packaged rooftop system to be matched to the heating requirements of the application. Two-stage heating provides staged operation for changing commercial heating loads.

6-Ton Two-Stage Cooling Performance

The RGF072LE2A0AAA is the 6-ton configuration within the RGF036-072 packaged rooftop platform. The manufacturer rates the RGF036-072 family at 13.4 SEER2, 11.5 EER2, and up to 15.5 IEER for the 6-ton configuration. The unit uses two-stage cooling to provide capacity control for varying commercial cooling requirements.

13.4 SEER2 / 11.5 EER2 / 15.5 IEER Efficiency and X-Vane™ Fan Technology

The RGF072LE2A0AAA combines efficient cooling performance with direct-drive ECM/Vane Axial X-Vane™ fan technology. The direct-drive design eliminates the conventional belt-driven fan arrangement while providing controlled indoor airflow. The RGF036-072 platform also incorporates two-speed fan operation for staged cooling applications.

Packaged Rooftop Installation Design

The packaged configuration integrates gas heating, electric cooling, indoor air movement, refrigeration components, and controls into one outdoor cabinet. The RGF072LE2A0AAA uses the L electrical configuration, corresponding to 460V, three-phase, 60 Hz service. The RGF platform provides convertible airflow capability to accommodate compatible rooftop installation requirements.

Controls & Comfort

The RGF platform provides two-stage heating and two-stage cooling operation. The direct-drive ECM/Vane Axial fan provides controlled indoor airflow, while the two-speed indoor fan supports staged operation. Available factory-installed control and ventilation options include economizers, CO2 sensing, outdoor-air sensing, and other commercial control configurations for compatible applications.

Light Commercial Applications

The ACiQ RGF072LE2A0AAA is designed for light commercial rooftop applications requiring integrated gas heating and electric cooling. Its 6-ton nominal size, medium-heat gas configuration, 460V three-phase electrical service, two-stage heating and cooling, two-speed indoor fan, and direct-drive X-Vane™ technology provide an integrated packaged heating and cooling solution.

Service & Maintenance

The direct-drive X-Vane™ fan eliminates conventional belt-driven fan components, helping simplify routine fan service. The RGF platform is designed with service-oriented features and available options including hinged access panels, fan/filter status monitoring, condensate overflow protection, non-fused disconnects, smoke detectors, phase monitoring, and fault detection and diagnostics.

Warranty

The ACiQ RGF072LE2A0AAA is covered by applicable manufacturer limited warranty provisions for the RGF packaged rooftop product family. AirQuest lists a 15-year limited warranty for stainless-steel heat exchangers, a 10-year limited warranty for aluminized heat exchangers, and applicable parts limited warranty provisions. Warranty periods, registration requirements, installation requirements, and other conditions are subject to the applicable manufacturer warranty certificate.

Recommended Accessories

  • Factory-Installed Economizer – Optional outdoor-air economizer for compatible ventilation and free-cooling applications.
  • CO2 Sensor – Optional sensing accessory for applicable demand-controlled ventilation applications.
  • Non-Fused Disconnect – Optional electrical disconnect for applicable installations.
  • Power Exhaust – Optional exhaust system for compatible economizer applications.
  • Condensate Overflow Switch – Optional condensate protection accessory.
  • Hinged Access Panels – Optional service-access configuration.

Reliable Commercial Comfort with the ACiQ RGF072LE2A0AAA

Experience reliable year-round commercial comfort with the ACiQ RGF072LE2A0AAA. Combining medium-heat two-stage gas heating and 6-ton two-stage electric cooling with direct-drive X-Vane™ fan technology, two-speed airflow, and a 460V three-phase packaged rooftop configuration for light commercial applications.

Packaged Unit Buyers Guide

  • How packaged units work for residential and commercial use
  • The different types of packaged units
  • Figuring out the right size unit for your needs
  • The importance of a custom curb adapter
  • And much more!
More Information
ACIQ 6 Ton 150,000 BTU 13.4 SEER2 Commercial Gas Packaged Unit - High Heat | 460V 3 Phase - R454B - Two Stage
FeatureSpec
SKURGF072LE2A0AAA
Refrigerant ChargePre-Charged
Weight647
ManufacturerACiQ
UPC686797046485
EquivalentCarrier: 48FCEM07A2A5-0A0A0
Furnace Efficiency / AFUE 80%
Cooling BTU70,000 BTU
Heating BTU150,000 BTU
Drive TypeDirect
Maximum CFM3260
Decibel Level (dBA)79 Decibels
RefrigerantR454B
SEER14
SEER213.4
EER11
IEER15.2
Condenser StagesTwo Stage
Compressor TypeScroll
Electrical460v 3 Phase 60 Hz
Electric Phase FilterThree Phase
Tonnage6 Ton
Burner StagesSingle
Height41 3/8"
Width46 5/8"
Depth74 3/8"
Warranty10 Years Aluminized Heat Exchanger, 5 Years Compressor, and 1 Year Parts
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety Information
This gas appliance requires a trained technician to install. Improperly connecting gas lines or improperly connecting a gas flue or venting may result in death. By purchasing this item, you are agreeing that you are using a trained technician to install this gas appliance. We will not be responsible for any injury or property damage arising from improper service or service procedures. Whoever installs or services this unit assumes responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install this equipment.

PROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:ACIQ 6 Ton 150,000 BTU 13.4 SEER2 Commercial Gas Packaged Unit - High Heat | 460V 3 Phase - R454B - Two Stage
Your Rating
Customer Questions
No Questions
Did you find what you were looking for?
Why Choose ACiQ?
Why Choose ACiQ?

ACiQ designs AC systems that are based on principles learned from nature: clean, energy-efficient, and quiet. ACiQ systems are built in a such a way that they are easily adapted to fit multiple variations a homeowner needs. ACiQ offers technology in mini-split and full split inverter system offerings that provide the smartest way to buy and save on your home’s comfort solution, so that it meets the needs of your family. ACiQ specializes in home comfort, regardless of your needs.

blockboard tech