Product Features
  • Designed for Easy Retrofit Installs
  • Custom Roof Curbs designed to fit your current adapter!
  • Precharged with R454b Refrigerant
  • 2-Stage Condenser
  • 208/230V 3 Phase
  • Up to a 10-Year Limited Warranty with Online Registration

Call 800-397-1392 for Best Prices!

6-Ton Medium-Heat Gas/Electric Packaged Rooftop Unit with X-Vane™ Technology for Light Commercial Applications

The ACiQ RGF072HE2A0AAA is a 6-ton gas/electric packaged rooftop unit designed for light commercial heating and cooling applications. This medium-heat configuration combines electric cooling and gas heating in a single outdoor cabinet and features direct-drive X-Vane™ fan technology with an electronically commutated motor. The unit uses R-454B refrigerant and is configured for 208/230V, three-phase electrical service.

Key Benefits

  • 6-Ton Cooling Capacity – Provides nominal 6-ton packaged cooling for light commercial applications.
  • 13.4 SEER2 / 15.5 IEER – Provides efficient seasonal and integrated part-load cooling performance for the RGF072 platform.
  • Medium-Heat Gas Heating – Provides gas-fired heating with up to 150,000 BTU of heating input and approximately 80% AFUE for this configuration.
  • Two-Stage Cooling – Provides staged cooling operation to help match system output to changing commercial loads.
  • R-454B Refrigerant – Uses R-454B refrigerant in the packaged refrigeration system.
  • Direct-Drive X-Vane™ Fan – Uses a Vane Axial fan with an electronically commutated motor, eliminating conventional belts, pulleys, blower bearings, and shafts.
  • Medium-Static Configuration – Provides airflow capability suited to commercial duct-system requirements.
  • 208/230V Three-Phase Electrical Service – Provides a three-phase electrical configuration for compatible commercial installations.
  • Convertible Rooftop Design – Supports field-convertible airflow configurations for installation flexibility.

Medium-Heat Gas Heating

The RGF072HE2A0AAA uses the medium-heat gas configuration and provides up to 150,000 BTU of gas-heating input. The heating system operates at approximately 80% AFUE, providing integrated gas-fired heating for commercial applications requiring substantial heating capacity from a packaged rooftop unit.

6-Ton Two-Stage Cooling Performance

The RGF072HE2A0AAA provides nominal 6-ton cooling capacity with approximately 70,000 BTU of rated cooling capacity. The unit uses two-stage cooling and is rated at 13.4 SEER2, 11.2 EER, and 15.5 IEER for the applicable configuration. R-454B refrigerant is used throughout the packaged refrigeration system.

Efficiency and X-Vane™ Fan Technology

The direct-drive X-Vane™ indoor fan system combines a Vane Axial fan with an electronically commutated motor. Compared with conventional belt-driven fan systems, the design eliminates fan belts, pulleys, shafts, and shaft bearings, reducing the number of moving components while providing efficient indoor-air movement. The RGF072 platform is also designed for high external static capability.

Packaged Rooftop Installation Design

The packaged configuration integrates gas heating, electric cooling, refrigeration components, indoor air movement, and controls into one outdoor cabinet. The RGF072HE2A0AAA uses 208/230V, three-phase, 60 Hz electrical service. The unit is designed for rooftop or compatible ground-level installation and supports field-convertible airflow arrangements.

Controls & Comfort

The unit includes a unit control board with clearly labeled connection points to simplify installation and service. The RGF platform provides high- and low-pressure protection, a filter drier, and 2-inch filters as standard equipment. The direct-drive ECM fan system provides controlled indoor airflow, while compatible options include economizers, power exhaust, dehumidification, CO2 sensing, condensate overflow protection, and other commercial controls.

Light Commercial Applications

The ACiQ RGF072HE2A0AAA is designed for light commercial rooftop applications requiring integrated gas heating and electric cooling. Its 6-ton nominal cooling size, medium-heat gas configuration, up to 150,000 BTU heating input, 208/230V three-phase electrical service, R-454B refrigerant, and direct-drive X-Vane™ fan technology provide a complete packaged heating and cooling solution.

Service & Maintenance

The direct-drive X-Vane™ fan eliminates conventional belt, pulley, shaft, and shaft-bearing components, helping simplify routine fan maintenance. Easy-access handles provide access to commonly serviced panels, while service gauge connections allow monitoring of compressor suction and discharge pressures and filter-drier operation during maintenance. The sloped, corrosion-resistant composite drain pan is designed to shed water and resist rust.

Warranty

The RGF072HE2A0AAA is covered by applicable manufacturer limited warranty provisions for the RGF packaged rooftop product family. Applicable coverage includes a 10-year limited warranty for the aluminized heat exchanger, a 5-year limited warranty for the compressor, and a 1-year limited warranty for replacement parts, subject to the applicable manufacturer warranty certificate, installation requirements, registration provisions, maintenance requirements, and exclusions.

Recommended Accessories

  • Economizer – Optional outdoor-air economizer for compatible ventilation and free-cooling applications.
  • Power Exhaust – Optional exhaust system for compatible economizer installations.
  • Hot Gas Re-Heat Dehumidification – Optional dehumidification system for improved part-load humidity control.
  • Non-Fused Disconnect – Optional electrical disconnect.
  • Condensate Overflow Switch – Optional condensate protection accessory.
  • CO2 Sensor – Optional carbon-dioxide sensing for compatible ventilation-control applications.

Reliable Commercial Comfort with the ACiQ RGF072HE2A0AAA

Experience reliable year-round commercial comfort with the ACiQ RGF072HE2A0AAA. Combining 6-ton electric cooling, medium-heat gas heating, R-454B refrigerant, two-stage operation, and direct-drive X-Vane™ fan technology in a packaged rooftop system designed for light commercial applications.

Packaged Unit Buyers Guide

  • How packaged units work for residential and commercial use
  • The different types of packaged units
  • Figuring out the right size unit for your needs
  • The importance of a custom curb adapter
  • And much more!
More Information
ACIQ 6 Ton 150,000 BTU 13.4 SEER2 Commercial Gas Packaged Unit - Medium Heat | 208/230V 3 Phase - R454B - Two Stage
FeatureSpec
SKURGF072HE2A0AAA
Refrigerant ChargePre-Charged
Weight647
ManufacturerACiQ
UPC686797046478
EquivalentCarrier Equivalent: 48FCFM07A2A5-0A0A0
Furnace Efficiency / AFUE 80%
Cooling BTU70,000 BTU
Heating BTU150,000 BTU
Drive TypeDirect
Maximum CFM3260
Decibel Level (dBA)79 Decibels
RefrigerantR454B
SEER14
SEER213.4
EER11
IEER15.2
Condenser StagesTwo Stage
Compressor TypeScroll
Electrical208/230v 3 Phase 60 Hz
Electric Phase FilterThree Phase
Tonnage6 Ton
Burner StagesSingle
Height41 3/8"
Width36"
Depth74 3/8"
Warranty10 Years Aluminized Heat Exchanger, 5 Years Compressor, and 1 Year Parts
Resources You will need Adobe® Acrobat® Reader to view PDF documents.
Safety Information
This gas appliance requires a trained technician to install. Improperly connecting gas lines or improperly connecting a gas flue or venting may result in death. By purchasing this item, you are agreeing that you are using a trained technician to install this gas appliance. We will not be responsible for any injury or property damage arising from improper service or service procedures. Whoever installs or services this unit assumes responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install this equipment.

PROPOSITION 65 WARNING
Write Your Own Review
You're reviewing:ACIQ 6 Ton 150,000 BTU 13.4 SEER2 Commercial Gas Packaged Unit - Medium Heat | 208/230V 3 Phase - R454B - Two Stage
Your Rating
Customer Questions
No Questions
Did you find what you were looking for?
Why Choose ACiQ?
Why Choose ACiQ?

ACiQ designs AC systems that are based on principles learned from nature: clean, energy-efficient, and quiet. ACiQ systems are built in a such a way that they are easily adapted to fit multiple variations a homeowner needs. ACiQ offers technology in mini-split and full split inverter system offerings that provide the smartest way to buy and save on your home’s comfort solution, so that it meets the needs of your family. ACiQ specializes in home comfort, regardless of your needs.

blockboard tech