We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
1-800-397-1392
Today's Hours 8am - 11pm estRequired Fields *
Out of stock
The Goodman GSZ 14 SEER Heat Pump uses the chlorine-free refrigerant R-410A and features energy efficiencies and operating sound levels that are among the best in the heating and cooling industry. The GSZ contains the single stage, high efficiency Copeland® scroll compressor, which provides improved temperature and humidity control. This unit is designed for the consumer who desires superb comfort and quiet operation.
The Goodman MBVC modular blower is tailor-made for exceptional energy efficiency. Now fully compatible with the ComfortNet line of communicating equipment, these two-piece blowers increase both installation and application flexibility. Units can be matched with cased coils for upflow, downflow, and horizontal applications.
Goodman's TXV valves are designed to improve the reliability and efficiency of your central split system. With the TX3N4, you can be assured that your two-and-a-half or three ton system is getting the proper refrigerant flow, even through changing conditions. Since this valve is installed externally, it is easy to service and maintain. If you're looking to improve the efficiency and performance of your system, the TX3N4 is a good start.
Please note that this is not an exhaustive list. Use Ctrl+F to simplify your search. This part is compatible with the following models:
GSX130301 GSX130361 DSXC160361 GSZ130301 GSZ130361 SSZ140301 SSZ140361 SSZ140381 SSZ160301 SSZ160361 DSZC160361 DSZC180361 CAPF3030*6 CAUF3030*6 CAPF3642*6 CAUF3642*6 CHPF3636B6 CSCF3036N6 CSCF3642N6
Ensure optimal refrigerant flow and HVAC system efficiency with this 30-foot insulated line set. Designed for seamless connection between an outdoor condensing unit or heat pump and an indoor air handler or evaporator coil, this line set provides durability, flexibility, and thermal protection for reliable performance.
✔ Premium Copper Tubing: 3/8" liquid line (LL) and 7/8" suction line (SL) ensure efficient refrigerant transfer.
✔ Pre-Insulated for Efficiency: 3/8" thick insulation reduces energy loss and condensation buildup.
✔ Versatile Application: Compatible with heat pumps and conventional split systems.
✔ Easy Installation: Flexible and durable copper tubing allows for smooth routing and connection.
✔ Standard 30-Foot Length: Ideal for a variety of residential and light commercial HVAC installations.
Upgrade your HVAC system with this high-quality insulated line set, designed for long-lasting performance and efficiency.
Ensure optimal refrigerant flow and HVAC efficiency with this 50-foot insulated line set. Designed for a seamless connection between an outdoor condensing unit or heat pump and an indoor air handler or evaporator coil, this line set provides durability, flexibility, and superior thermal insulation for reliable system performance.
✔ Premium Copper Tubing: 3/8" liquid line (LL) and 7/8" suction line (SL) for efficient refrigerant transfer.
✔ Pre-Insulated for Efficiency: 3/8" thick insulation minimizes energy loss and condensation buildup.
✔ Versatile Application: Ideal for heat pumps and conventional split systems.
✔ Easy Installation: Flexible and durable copper tubing allows for smooth routing and secure connections.
✔ Extended 50-Foot Length: Perfect for larger residential and light commercial HVAC installations.
Upgrade your HVAC system with this high-quality insulated line set, designed for long-lasting performance and energy efficiency.
This 240 volt heater coil can be added to a Goodman air handler to provide winter-time heating capabilities.
Produces 34,100 BTUs of heat.
Controlled by sequencers for optimum temperature balance. Completely assembled and tested. Built-in overcurrent protection on all units as indicated in electrical data chart (see spec sheet). Multiple branch circuit capability. High temperature limit controls for safe operation. Plug-in wiring harness for easy installation into air handlers. Rust-resistant nickel chromium heat elements.
If you are installing a heater coil in an air handler, line voltage is to be connected directly to the heater coil which will operate both the heater coil and air handler. A separate circuit for the air handler is not needed. If you are installing the heater coil in a packaged air conditioner or heat pump, another circuit in addition to the heater coil circuit(s) is still required to operate the packaged unit
Depending on the heater coil size being installed, one or two circuits to the heater coil will be necessary (see "PRODUCT SPECIFICATIONS" below for quantity and amperage of circuits required for this heater coil.) At your home's circuit panel, individual 220 volt double-pole circuit breakers are required for each circuit.
Buyers frequently report fast delivery—often within a couple of days or as little as two to four days—with equipment arriving well packaged and undamaged, and several note significant savings such as $2,700 versus a $5,200 estimate or thousands less than local HVAC companies and wholesalers. Performance feedback is largely positive after installation, including 2‑week to 7‑month ownership reports and one homeowner replacing a 20‑year‑old Goodman unit, though minor issues include a dented outdoor unit, limited shipping notice, delivery placement constraints, and a metallic-sounding Reichi compressor on one 2‑ton model.
Posted on
Posted on
Posted on
Posted on
Posted on
Posted on
Posted on
Posted on